
Distributor for capillaries, PTFE
Distributor with 3 x PFA fittings for connecting capillaries (O.D. 3.2 mm).

Distributor for capillaries, PTFE
Distributor with 3 x PFA fittings for connecting capillaries (O.D. 3.2 mm).

Eluent SafetyCap Starter Kit I
Starter kits for HPLC with up to 4 storage bottles. The kits also contain air valves, fittings for connecting capillaries, and blind fittings for closing connections that are not required.Scope of supply: 4 x Eluent SafetyCaps with 1 PP fitting, 4 x air valves

Eluent SafetyCap Starter Kit II
Starter kits for HPLC with up to 4 storage bottles. The kits also contain air valves, fittings for connecting capillaries, and blind fittings for closing connections that are not required.Scope of supply: 3 x Eluent SafetyCaps with 1 PP fitting, 1 x Eluent SafetyCap with 2 PP fittings, 4 x air valves, 1 x blind fitting

Eluent SafetyCap Starter Kit III
Starter kits for HPLC with up to 4 storage bottles. The kits also contain air valves, fittings for connecting capillaries, and blind fittings for closing connections that are not required.Scope of supply: 4 x Eluent SafetyCaps with 2 PP fittings, 4 x air valves, 4 x blind fittings

Eluent SafetyCaps
Suitable for solvent extraction. The integrated air valve blocks hazardous solvent vapours and filters the incoming air via a PTFE membrane. All unused capillary positions must be closed with a blind fitting.With timestrip stickerClosures and fittings made of PPBody made of PTFE

Exhaust filter for barrels, PE
The exhaust filters, filled with activated carbon, prevent harmful solvent vapours from leakage.Lid with aeration openingsLabelling field to monitor service lifeXL for 60 - 100 l barrelsXXL for barrels from 100 l

Exhaust Filter, PP
Lid with integrated ventilation openings and service life indicator. The filling of activated carbon is protected by two porous membranes made of PE. This allows an unobstructed flow of exhaust air, solvents are adsorbed by the activated carbon and only filtered air streams out.

Exhaust filters for Waste SafetyCaps
The exhaust filter cleans the exhaust air of HPLC waste. The activated carbon in the exhaust filter is optimised for the absorption of organic solvent vapours. With timestrip sticker for timely replacement of the exhaust filter.

Exhaust filters V3.0, with change indicator
The exhaust air filters are equipped with three different activated carbon layers, which bind acids and alkalis and adsorb organic solvent vapours. Depending on the required capacity, filter with different service lifes are available.Filter media with a very high performance spectrum for acids and alkalisOptimised for binding buffer solutions and solvent vapoursWith splash guard1500 m²/g adsorption surface area

Exhaust filters V3.0, with change label
The exhaust air filters are equipped with three different activated carbon layers, which bind acids and alkalis and adsorb organic solvent vapours. Depending on the required capacity, filter with different service lifes are available.Filter media with a very high performance spectrum for acids and alkalisOptimised for binding buffer solutions and solvent vapoursWith splash guard1500 m²/g adsorption surface area

Fittings for Eluent SafetyCaps / Waste SafetyCaps
For filling the capillary positions of SafetyCaps.

Fittings for SafetyCaps / SafetyWasteCaps
Fittings with integrated ferrule for SafetyCaps and SafetyWasteCaps.Use the blind plugs to tighten connectors which are temporarily inactive or not in use.

Fittings preparative, PTFE, for Caps
For fixing tubes in the tubing connectors (thread NPT 1/8“) of b.safe Caps.

Fittings, PE, PFAS Analytic
For fixing tubes in the capillary connections of b.safe Caps.

Fittings, PFA, for Caps and Waste Caps
For fixing tubes in capillary connections (thread UNF 1/4" 28G) of b.safe Caps and b.safe Waste Caps.

Fittings, PP, for PFAS analysis
For fixing tubing in the capillary connections. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.

Flanged Tubing, PTFE, PA
Flanged PTFE tubing with black tube end fittings UNF ¼" 28 G made of PP and washers made of PA. The tubing is ready for use. Temperature resistant from 0 to +100 °C, pressure resistant up to 30 bar, universal chemical resistance.

Flexible connecting system for DURAN® GL 45 flasks
For safe transfer of liquid media within a closed and sterile system (evaporation is reduced).Screw closure GL 45 with two, three or four ports GL 14 threadAutoclavableTemperature restistant up to max. 140 °CFlexible modular systemSterile pressure equalisation is possible through use of a membrane filterUnused ports can be provided with a blind cap


Funnels for Safety Waste Caps V3.0, HDPE, electrostatic conductive
Lid with sealing ringWith grounding cable

Holders for capillaries and tubing, ABS
For fixation of capillaries and tubing (up to 8 x O.D. 1,6 mm / 3 x O.D. 3,2 mm or 1 x O.D. 5 mm). With self-adhesive bottom side.

Hose connectors for Waste Caps
For the connection of tubing on b.safe Waste Caps.
Hose connectors for Waste Caps with luerlock connection
For the connection of tubing on b.safe Waste Caps.

Hose connectors for Waste SafetyCaps
For connecting hoses to the capillary positions of the Waste SafetyCaps.

HPLC bottle distributors
Made of glass-fibre reinforced polypropylene (PP). Up to four tubes (preferably PTFE) can be connected to bottles at once. Distributors can be screwed on to any container with a GL45 neck via the screw cap. Supplied with all accessories (screw caps, silicone rings or O-rings, sealing caps) for immediate use. Choice of model; with, or without stopcock.

HPLC bottles, DURAN® complete system 4-port screw cap
For sterile transfer of media or for feeding solvent to HPLC instruments. The bottle is pressure/vacuum resistant from -1 to +1.5 bar (tested by TÜV in accordance with EN 1596, GS marked). Complete with a 4-port screw cap (autoclavable, reusable) made from PP, 4 connection screw caps (black, M8 thread) and silicone seal. Suitable for tube diameters of 1.6mm and 3.2mm. Spare parts are available individually. Further connection system components for the GL45 thread are available upon request (Tubing not included). Neutral / Type I glass acc. to USP/EP. With Retrace Code (Batch Identification), with certificate available via the internet. Autoclavable.

HPLC reservoir bottles DURAN®, borosilicate 3.3 glass, with conical base
The DURAN® reservoir bottles have been designed for use in high-performance liquid chromatography (HPLC) and allows longer, uninterrupted analyses. A central cavity in the bottom of the bottle allows mobile phases and solvents to be dispensed without tilting the bottle. Side vent hole in the base for ultrasonic bath degassing, or water drainage after cleaning. Screw caps HPLC (PTFE, GL 45, 3 ports) available as accessories.GL 45 ThreadISO 3585Type I neutral glass, by USP / EPWith Retrace Code and certificate for manufacturing lot traceabilityAvailable in four sizes: 1, 2, 5, or 10 Litres5 and 10 litre bottles can accommodate magnetic stirring barsDurable white enamel volume graduationsAutoclavable at 121 °C or 134 °C

HPLC Safety Set Generation 2.0
HPLC Safety Set HPLC Safety Set Generation 2.0 suitable for all HPLC SystemsComplete system for safe extraction and disposal of solvents.One single set for Solvent supply and Waste:4x SafetyCap III HPLC Safety Set (Generation 2.0) GL45 4x Air valve HPLC Safety Set (Generation 2.0) comes with SafetyCap III4x Solvent bottle 1 L, GL45, glass 10x Blind plug for capillary connections 5x Fittings ID 2.3 mm violet 5x Fittings ID 3.2 mm blue 5x Fitting ID 1,6 mm green5x Fittings ID 3.2 mm yellow1x Tube fitting, curved, 6.4-9.0 mm (comes with SafetyWasteCap GL45)1x SafetyWasteCap HPLC Safety Set (Generation 2.0) GL451x Exhaust filter HPLC Safety Set (Generation 2.0) size M1x Container 5 L, GL45, HDPE2x Tube fitting, straight, 6-8 mm1x Tube fitting, angled, 9.5-10 mm

HPLC starter kit I, GreenLine, GL45, for PFAS analysis
For the safe withdrawal of solvents. Screw caps, with freely movable insert, with fittings for capillaries and an air valve, with change indicator. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.Complete set for up to 4 storage bottlesSuitable for all current HPLC systemsScope of supply:3 x Safety Cap I, GL 45, PEEK, PFAS-Analytic1 x Safety Cap II, GL 45, PEEK, PFAS-Analytic4 x air valve, PFAS-Analytic4 x change indicator5 x PE fitting 1.6 mm OD5 x PE fitting 2.3 mm OD5 x PE fitting 3.2 mm OD1 x PE blind plug4 x labelling field

HPLC starter kit II, GreenLine, GL45, for PFAS analysis
For the safe withdrawal of solvents. Screw caps, with freely movable insert, with fittings for capillaries and an air valve, with change indicator. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.Complete set for up to 4 storage bottlesSuitable for all current HPLC systemsScope of supply:4 x Safety Cap II, GL 45, PEEK, PFAS-Analytic4 x air valve, PFAS-Analytic4 x change indicator8 x PE fitting 1.6 mm OD8 x PE fitting 2.3 mm OD8 x PE fitting 3.2 mm OD4 x PE blind plugs4 x labelling field

HPLC starter kit III, GreenLine, GL45, for PFAS analysis
For the safe withdrawal of solvents. Screw caps, with freely movable insert, with fittings for capillaries and an air valve, with change indicator. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.Complete set for up to 4 storage bottlesSuitable for all current HPLC systemsScope of supply:4 x Safety Cap III, GL 45, PEEK, PFAS-Analytic4 x air valve, PFAS-Analytic4 x change indicator12 x PE fitting 1.6 mm OD12 x PE fitting 2.3 mm OD12 x PE fitting 3.2 mm OD8 x PE blind plugs4 x labelling field

HPLC starter kit IV, GreenLine, GL45, for PFAS analysis
For the safe withdrawal of solvents. Screw caps, with freely movable insert, with fittings for capillaries and an air valve, with change indicator. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.Complete set for up to 4 storage bottlesSuitable for all current HPLC systemsScope of supply:4 x Safety Cap IV, GL 45, PEEK, PFAS-Analytic4 x air valve, PFAS-Analytic4 x change indicator16 x PE fitting 1.6 mm OD16 x PE fitting 2.3 mm OD16 x PE fitting 3.2 mm OD12 x PE blind plugs4 x labelling field

HPLC starter kit VI, GreenLine, GL45, for PFAS analysis
For the safe withdrawal of solvents. Screw caps, with freely movable insert, with fittings for capillaries and an air valve, with change indicator. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.Complete set for up to 4 storage bottlesSuitable for all current HPLC systemsScope of supply:4 x Safety Cap VI, GL 45, PEEK, PFAS-Analytic4 x air valve, PFAS-Analytic4 x change indicator24 x PE fitting 1.6 mm OD24 x PE fitting 2.3 mm OD24 x PE fitting 3.2 mm OD20 x PE blind plugs4 x labelling field

HPLC starter kits 1, Generation 2.0, GL 45
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries and an air valve. For maximum efficiency, we recommend that the vent is changed every 6 months.Complete set for one HPLC system with up to 4 solvent reservoirsPrice advantage compared to ordering piece by pieceSuitable for all current HPLC systemsUse the supplied blind plugs to tighten connectors which are temporarily inactive or not in useScope of supply: 3 x SafetyCaps I, 1 x SafetyCap II, 4 x air valve, 4 x change indicator, 5 x 1,6/ 5 x 2,3/ 5 x 3,2 mm PFA fittings, 1 x PFA blind plug, 4 x labelling field

HPLC starter kits 2, Generation 2.0, GL 45
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries and an air valve. For maximum efficiency, we recommend that the vent is changed every 6 months.Complete set for one HPLC system with up to 4 solvent reservoirsPrice advantage compared to ordering piece by pieceSuitable for all current HPLC systemsUse the supplied blind plugs to tighten connectors which are temporarily inactive or not in useScope of supply: 4 x SafetyCaps II, 4 x air valve, 4 x change indicator, 8 x 1,6/ 8 x 2,3/ 8 x 3,2 mm PFA fittings, 4 x PFA blind plugs, 4 x labelling field