Caps for TrayCell
Traditional spectrophotometrical analysis of nucleic acids is carried out in 10mm cuvettes. Modern drop analysis uses light paths of 1mm and 0.2mm and it is thus not necessary to dilute the sample. In applications with very high or very low DNA concentrations these light paths are often no longer sufficient. When using the TrayCell from Hellma Analytics simply adjust the light path by exchanging the cap. Cap with integrated mirror to change the light path.

Cell storage container, Küvibox 2
Dust-proof, rigid container for storing clean cells. Accommodates cells up to 55mm in height. Cells are immediately ready for use when required.Küvibox 1 holds up to 16 x 10mm path length cellsKüvibox 2 holds up to 8 x 10mm and up to 4 x 20mm path length cells.

Cells for absorption measurement, flow-through measurement, UV-range, 2 screw terminals
M 6 x 1 and FEP tubes (outside diameter 1.9 mm, inner diameter 1.1 mm, length 500 mm).
Cells for absorption measurement, flow-through measurement, UV-range, supply and outlet tubes
Optical material: Quartz glass High Performance.
Cells for Absorption Measurement, NIR-range
300 Wavelength Range: 200nm - 3500nmOptical material: Quartz glass Extended Range


Cells for absorption measurement, UV-range
Optical material: Quartz glass High Performance.

Cells for absorption measurement, UV-range, black side walls and base
Optical material: Quartz glass High Performance.
Cells for absorption measurement, UV-range, for magnetic stirring bars
Optical material: Quartz glass High Performance.
Cells for absorption measurement, UV-range, with loose sheets of glazing
Optical material: Quartz glass High Performance.
Cells for absorption measurement, UV-range, with open screw cap
Optical material: Quartz glass High Performance.Optical material: Quartz glass High Performance. With silicone rubber seal and with ISO thread GL14.
Cells for absorption measurement, UV-range, with pipe
Optical material: Quartz glass High Performance.Optical material: Quartz glass High Performance. Pipe-Ø 8mm, nozzle length 80 mm.



Cells for fluorescence measurement, UV-range
Optical material: Quartz glass High Performance.

Cells for fluorescence measurement, UV-range, 3 window
Optical material: Quartz glass High Performance.
Cells for fluorescence measurement, UV-range, 5 window
Optical material: Quartz glass High Performance.

Cells for fluorescence measurement, UV-range, for magnetic stirrers
Optical material: Quartz glass High Performance.
Cells for fluorescence measurement, UV-range, screw cap, with silicone rubber seal
Optical material: Quartz glass High Performance.

Cells for fluorescence measurement, UV-range, with connector
Optical material: Quartz glass High Performance.Connection Ø 8 mm, length 80 mm spigot.

Cells for light scattering measurements, UV-range
Wavelength: 200nm - 2500nmOptical material: Quartz glass High Performance

Certified reference materials for qualifying spectrophotometer as a complete set
To maintain constant good measurement results, a regular review of the accuracy of the spectrophotometer is required. With the use of certified reference materials from Hellma Analytics, you make sure that your equipment qualifications meet the requirements of the pharmacopoeias and fulfill your internal quality requirements, at the same time you reach the international comparability of your measurement results. The certified reference materials (calibration standards) of the DIN EN ISO 17025 accredited Hellma Analytics calibration laboratory are traceable to the primary standards of NIST (National Institute of Standards and Technology) and meet the requirements of the major pharmacopoeias (e.g. EP, DAB, USP).Your benefits: High quality of the measurement resultsInternational comparability of measurement resultsMeeting the requirements of the major pharmacopoeias (EP, DAB, USP)Results traceable to NIST primary standards30 years warranty on the reference materialsScope of delivery: Certified reference materials (Calibration Standards) in quality storage boxDAkkS Calibration Certificate (DIN 17025)Handling guidelinesGlass Filters 666-S000: For testing spectrophotometers. Photometric accuracy and wavelength accuracy in the visible spectral region.Liquid Filters 667.033-UV: For testing spectrophotometers according to European Pharmacopoeia, wavelength accuracy, photometric accuracy, stray light behaviour, resolution.Filters also available individually.

Cuvette for turbidity measurements, VIS-range
Wavelength: 360nm - 2500nmOptical Material: Optical glass
Cylindrical cells for polarimetric measurements, UV-range
Optical material: Quartz glass High Performance.

Cylindrical cells for polarimetric measurements, UV-range, 2 sleeve sections with PTFE stopper
Optical material: Quartz glass High Performance.

Flow-through cells with two optical paths lengths, Absorption and Fluorescence Measurement
Wavelength Range: 200nm - 2500nmOptical material: Quartz glass High Performance
Holder for absorption cells
Cuvette holder for absorption measurements in the UV range, with loose window panels.

LLG-Cuvettes
LLG-Cuvettes are most frequently used in analytical laboratories.They have two clear windows, two side walls and are available as optical glass or quartz variants. The walls and the base are polished inside and frosted outside. The thickness of the windows and the base is 1.25 mm. The overall height of standard type cells is 45 mm or 48 mm for those fitted with a stopper. Each cuvette is supplied with a PTFE lid.Optical Glass: 335 to 2500 nmQuartz: 200 to 2700 nm

Macro cells for absorption measurement, NIR-range, quartz glass Extended Range
Base thickness 1.5 mm.

Macro cells for absorption measurement, UV-range, quartz glass High Performance
Base thickness 1.5 mm.

Macro cells for absorption measurement, VIS-range, special optical glass
Base thickness 1.5 mm.

Micro plates, quartz glass
96-well-plates. Quartz glass, with synthetic quartz glass base. Ideal for use with aggressive media, for UV-range measurements, in microscopy, or in fluorescence studies.

Micro Volume Analysis TrayCell
Fibre-Optic Micro Measuring Cell. Accessory for standard spectrophotometer for droplet analysis.Sample volume 0.7µl to 10µl.Typical applications are:nucleic acid analysis.determination of the incorporation frequency of fluorescent dye labels (FOI).protein analysis (A280, BCA, Lowry etc.).all UV / Vis analysis utilising wavelength range 190nm to 1100nm.material: Quartz glass High Performance.Please state the required cell centre height (8.5mm, 15mm or 20mm) when placing your order! TrayCell is supplied as standard with caps for both 0.2mm and 1mm light path. Additional light path of 0.1mm and 2mm are available.

Micro volume measuring cell TrayCell 2.0
Fibre-optic micro volume measuring cell for UV/VIS-based microvolume analysis. Suitable for all current spectrophotometers with standard cuvette holder.Purity and concentration determination of DNA/RNA and proteinsDetermination of labelling efficiency for microarray experimentsPrecisely defined path lengths prevent misadjustmentRecovery of samples by simple pipetting offSamples with low surface tension can be measuredQuick and easy cleaningPlease indicate the centre height when placing your order!Scope of supply: Cuvette, lid for the indicated layer thicknesses