Polarimeter P1000-LED
For basic lab applications and training, for example the experiment on saccharose inversion.Measurement of optical rotation according to the half-shade principleManual adjustment on the scaleMeasurement results are read through an eyepiece and two noniusesHigh-performance LED with a service life of 100,000 hTube chamber for tubes with a length of up to 220 mmIncludes two measurement tubes with a debubblerLow-maintenance, cost-effective solution

Polarimeter P3000
Technologically high-quality polarimeter for standard applications for which a measurement accuracy of ±0.01° is sufficient and a temperature control can be omitted. Typically, the P3000 is used in the quality control of food industry.Measurement of optical rotationVery short measurement time of approx. 1 sEasy, menu-driven adjustmentDisplay of measured values in optical rotation or international sugar scaleSuitable tubes for any type of sampleMeasurement up to an optical density of 3.0Temperature measurement with calibratable temperature sensorReliable temperature compensationChemical-resistant measurement tubesCompliance with GMP/GLP, pharmacopoeias [USP, BP, JP, Ph. Eur. (with tempering)], FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST

Polarimeter PL1
Simple and sturdy instrument to measure the rotation angle of optically active substances. The measure in 180° is directly readable on two mechanical dials.Light source: LED lamp (589.3 nm)Polarimetiric Tubes one 100 mm and one 200 mmDust coverOptical Glass Windows (4 pcs)Rubber sealsFuses

Polarimeter Polax-2L
The Polax-2L (manually-operating meter with digital indicator) is widely used in the sugar, pharmaceutical, chemical, perfume and educational industries. It can accurately measure the angle of rotation (or the value in the international standard sugar scale) with easy operation.

Polarimeter tubes, low volume
Polarimeter tube made of stainless steel with precision-ground window made of low-strain silica. The sample inlet and outlet are via UNF 28 female threads and PTFE pipe connectors. The sample can be syringed into the tube or pumped through the tube as part of an automatic sampling system.

Polarimeters P8000, without sample temperature control
Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)

Polarimeters P8000-P, with Peltier sample temperature control
Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)

Polarimeters P8000-T, with water temperature control
Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)

Polarimeters P8000-TF, with water temperature control and flow function
Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)Polarimeters with patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample's angle of rotation. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards.Fast reliable measurement up to an optical density of 3.0 OD, measurement time of approx. 1 sEasy, menu-driven adjustmentAny number of freely configurable methodsSuitable measurement tube for any type of sampleTemperature measurement directly inside the sampleReliable temperature compensationComplete documentation of measured valuesCompliance with global standards (GMP/GLP, 21 CFR Part 11, Pharmacopoeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST)
Printer CMB-910
Miniature 24-column dot matrix printer for the direct recording of data from digital refractometers and polarimeters. Recommended for Good Laboratory Practice applications. With serial RS232 interface. Power supply 110 to 230 V with EU/UK/US plug.

Pt-Co Reference Standards
Bottles of 500 ml, certified according to QS System, ISO 9001. Shelf life 12 months. Other versions available on request.




Reflectance spectrophotometer TR 500
Ergonomic and flexible reflection spectrophotometers for measuring samples in different industries including food, medicine, coatings and plastics. The on-board camera-based locator and the black and white calibration plates ensure precise measurements and results at all times.CMOS sensor (256 picture elements, double array)Intuitive 3.5 inch TFT color LCD (capacitive), symbol-basedFree PC-based OnShade software which allows graphs and statistical process controlOperation languages: English, French, German, Spanish, Portuguese, ChineseCustomer-specific aperturesExternal memory with 2000 standards and 20000 samplesScope of supply: Reflectance spectrophotometer, OnShade PC software, black and white calibration board (white tile and black interface), dust cover, USB cable, external DC power supply, USB stick with user manual in the operating languages, carrying caseSpecificationsLight source:combined LED lightIlluminant:D65, A, C, D50, D55, D75, F2, F7, F11Repeatability:MAV/SCI: ΔE ≤0.05Inter instrument agreement:MAV/SCI: ΔE ≤0.2Dimensions (W x D x H):184 x 105 x 77 mmWeight:600 gOptical geometry:di: 8°, de: 8°Specular component:SCI, SCEColour space:CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LabColour difference formular:ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00v, ΔE (Hunter)Other colorimetic index:WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM, E313, CIE/ISO), metamerism index (MI), staining fastness, colour fastness and strength, opacitySpectral range:400 ... 700 nmSpectral interval:10 nmMemory:2000 standards, 20000 samplesInterface:USB, Bluetooth® 4.0Power supply:Li-ion battery

Reflectance spectrophotometer TR 515
Ergonomic and flexible reflection spectrophotometers for measuring samples in different industries including food, medicine, coatings and plastics. The on-board camera-based locator and the black and white calibration plates ensure precise measurements and results at all times.CMOS sensor (256 picture elements, double array)Intuitive 3.5 inch TFT color LCD (capacitive), symbol-basedFree PC-based OnShade software which allows graphs and statistical process controlOperation languages: English, French, German, Spanish, Portuguese, ChineseSwitchable aperture (Ø 8 mm/Ø 4 mm) for adapting the measurement size to the surfaceWith the 45°/0° geometry, the device can measure the reflectance colour spectra of samples. This enables it to determine accurate colour difference values, formulas and indices in common colour spacesExternal memory with 1000 standards and 30000 samplesScope of supply: Reflectance spectrophotometer, OnShade PC software, black and white calibration board (white tile and black light trap), dust cover, USB cable, external DC power supply, USB stick with user manual in English and Chinese, carrying caseSpecificationsLight source:combined LED light, UV lightIlluminant:D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12Inter instrument agreement:Within ΔE*ab 0.15 (Average for 12 BCRA Series II colour tiles)Dimensions (W x D x H):184 x 105 x 77 mmWeight:600 gOptical geometry:45°/0°Colour space:CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LabColour difference formular:ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00v, ΔE (Hunter)Other colorimetic index:WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), metamerism index (MI), staining fastness, colour fastness and strength, opacitySpectral range:400 ... 700 nmSpectral interval:10 nmMemory:1000 standards, 30000 samplesInterface:USB, Bluetooth® 4.0Power supply:Li-ion battery

Reflectance spectrophotometer TR 520
Ergonomic and flexible reflection spectrophotometers for measuring samples in different industries including food, medicine, coatings and plastics. The on-board camera-based locator and the black and white calibration plates ensure precise measurements and results at all times.CMOS sensor (256 picture elements, double array)Intuitive 3.5 inch TFT color LCD (capacitive), symbol-basedFree PC-based OnShade software which allows graphs and statistical process controlOperation languages: English, French, German, Spanish, Portuguese, ChineseDual aperturesMeasurement of fluorescent materials with UV on/offExtended range of illuminantsExternal memory with 2000 standards and 20000 samplesScope of supply: Reflectance spectrophotometer, OnShade PC software, black and white calibration board (white tile and black interface), dust cover, USB cable, external DC power supply, USB stick with user manual in the operating languages, carrying caseSpecificationsLight source:combined LED light, UV lightIlluminant:D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12Repeatability:MAV/SCI: ΔE ≤0.03Inter instrument agreement:MAV/SCI: ΔE ≤0.15Dimensions (W x D x H):184 x 105 x 77 mmWeight:600 gOptical geometry:di: 8°, de: 8°Specular component:SCI, SCEColour space:CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LabColour difference formular:ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00v, ΔE (Hunter)Other colorimetic index:WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM, E313, CIE/ISO), metamerism index (MI), staining fastness, colour fastness and strength, opacitySpectral range:400 ... 700 nmSpectral interval:10 nmMemory:2000 standards, 20000 samplesInterface:USB, Bluetooth® 4.0Power supply:Li-ion battery

Reflectance spectrophotometer TRA 500
Combination of spectrophotometer TR 500 and portable docking station for precise and repeatable measurements of liquids, gels and powders. The precisely fitting docking station was specially developed for the TR 500 so that ambient lighting can not enter the sample. Different glass cells offer a wide range of applications. With their robust shape, the devices are ideal for use in every laboratory.CMOS sensor (256 picture elements, double array)Intuitive 3.5 inch TFT color LCD (capacitive), symbol-basedExternal memory with 2000 standards and 20000 samplesFree PC-based OnShade software which allows graphs and statistical process controlOperation languages: English, French, German, Spanish, Portuguese, ChineseMeasurements are easy-to-read through the angled viewing windowIntegrated cover prevents the effects of extraneous lightScope of supply: Spectrophotometer TR 500, complete TR 500 accessories, sample cover, white background plate, 3 x optical glass cells (10, 20, 30 mm)SpecificationsLight source:combined LED lightIlluminant:D65, A, C, D50, D55, D75, F2, F7, F11Repeatibility:MAV/SCI: ΔE ≤0.05Inter instrument agreement:MAV/SCI: ΔE ≤0.2Dimensions (W x D x H):207 x 170 x 130 mmWeight:1200 gOptical geometry:di: 8°, de: 8°Specular component:SCI, SCEColour space:CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LabColour difference formular:ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00v, ΔE (Hunter)Other colorimetic index:WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM, E313, CIE/ISO), metamerism index (MI), staining fastness, colour fastness and strength, opacitySpectral range:400 ... 700 nmSpectral interval:10 nmMemory:2000 standards, 20000 samplesInterface:USB, Bluetooth® 4.0Power supply:Li-ion battery

Reflectance spectrophotometer TRA 520
Combination of spectrophotometer TR 520 and portable docking station for precise and repeatable measurements of liquids, gels and powders. The precisely fitting docking station was specially developed for the TR 520 so that ambient lighting can not enter the sample. Different glass cells offer a wide range of applications. With their robust shape, the devices are ideal for use in every laboratory.CMOS sensor (256 picture elements, double array)Intuitive 3.5 inch TFT color LCD (capacitive), symbol-basedExternal memory with 2000 standards and 20000 samplesFree PC-based OnShade software which allows graphs and statistical process controlOperation languages: English, French, German, Spanish, Portuguese, ChineseDual aperturesMeasurement of fluorescent materials with UV on/offExtended range of illuminantsMeasurements are easy-to-read through the angled viewing windowIntegrated cover prevents the effects of extraneous lightScope of supply: Spectrophotometer TR 520, complete TR 520 accessories, sample cover, white background plate, 3 x optical glass cells (10, 20, 30 mm)SpecificationsLight source:combined LED light, UV lightIlluminant:D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12Repeatability:MAV/SCI: ΔE ≤0.03Inter instrument agreement:MAV/SCI: ΔE ≤0.15Dimensions (W x D x H):207 x 170 x 130 mmWeight:1200 gOptical geometry:di: 8°, de: 8°Specular component:SCI, SCEColour space:CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LabColour difference formular:ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00v, ΔE (Hunter)Other colorimetic index:WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM, E313, CIE/ISO), metamerism index (MI), staining fastness, colour fastness and strength, opacitySpectral range:400 ... 700 nmSpectral interval:10 nmMemory:2000 standards, 20000 samplesInterface:USB, Bluetooth® 4.0Power supply:Li-ion battery

Saccharimeter ADS435-F/ADS438-F, with funnel flow tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation but works best when connected to an RFM300 or RFM700 refractometer. By connecting a digital refractometer, a complete purity system can be created that enables accurate purity measurements.High resolution 4" full colour display with easy-to-use keypadContinuous measurement or single measurementsLED light sourceRFID user identificationData memory for over 8000 readingsMethod system with limit valuesUSB "Back-up & Clone"User maintenance promptssUSB (A), USB (B), and Ethernet interfaceAll packages are supplied with corresponding cell, lid, integrated purity, LIMS logger PC software, RFID tags, and declaration of conformity.Funnel flow tubes are ideal for high sample throughput

Saccharimeter ADS435/ADS438, with glass tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation but works best when connected to an RFM300 or RFM700 refractometer. By connecting a digital refractometer, a complete purity system can be created that enables accurate purity measurements.High resolution 4" full colour display with easy-to-use keypadContinuous measurement or single measurementsLED light sourceRFID user identificationData memory for over 8000 readingsMethod system with limit valuesUSB "Back-up & Clone"User maintenance promptssUSB (A), USB (B), and Ethernet interfaceAll packages are supplied with corresponding cell, lid, integrated purity, LIMS logger PC software, RFID tags, and declaration of conformity.The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation but works best when connected to an RFM300 or RFM700 refractometer. By connecting a digital refractometer, a complete purity system can be created that enables accurate purity measurements.High resolution 4" full colour display with easy-to-use keypadContinuous measurement or single measurementsLED light sourceRFID user identificationData memory for over 8000 readingsMethod system with limit valuesUSB "Back-up & Clone"User maintenance promptssUSB (A), USB (B), and Ethernet interfaceAll packages are supplied with corresponding cell, lid, integrated purity, LIMS logger PC software, RFID tags, and declaration of conformity.

Saccharimeter ADS455-F/ADS458-F, with XPC temperature control and funnel flow tube
The Saccharimeter is a dedicated polarimeter that displays results in °Z according to the ISS scale and is suitable for sugar laboratories, factories, and raw material receiving centres. The device is designed to operate in isolation but works best when connected to an RFM300 or RFM700 refractometer. By connecting a digital refractometer, a complete purity system can be created that enables accurate purity measurements.High resolution 4" full colour display with easy-to-use keypadContinuous measurement or single measurementsLED light sourceRFID user identificationData memory for over 8000 readingsMethod system with limit valuesUSB "Back-up & Clone"User maintenance promptssUSB (A), USB (B), and Ethernet interfaceAll packages are supplied with corresponding cell, lid, integrated purity, LIMS logger PC software, RFID tags, and declaration of conformity.Patented, integrated Peltier temperature control systemFunnel flow tubes are ideal for high sample throughput