Eppendorf Cuvette rack, PP
Numbered positions for easy handling and identificationMade of high quality polypropylene (PP) for chemical and physical resistanceTemperature stability from -86 °C to 121 °CAutoclavable (121 °C, 20 min)Laboratory washer-safe for easy cleaningStackable to save lab space

Flame Photometer FF-200
Single channel, low temperature flame photometer for use in industry, medicine and education. Can be operated with propane, butane, natural gas or liquid gas (LPG). With built-in electronic flame failure safety system for operational safety.Model FF-200D-I incl. Na, K, Ca, Ba and Li filtersModel FF-200D-R incl. Na, K and Li filters3 year warrantySupplied with: Na, K, Li filters (model FF-200D-R), additionally Ba and Ca filter (model FF-200D-I), connecting hoses and clips, compressor plug, drain trap, fuses and operating/service instructionsSpecificationsRange FF-200D-I: Range FF-200D-R: Limits of detection Na/K: Li: Ca: Ba:0 ... 199.9 ppm 120 ... 160 ppm Na, 0 ... 10 ppm K 0.2 ppm 0.25 ppm 15 ppm 30 ppmReproducibility: 1 % (Coefficient of variation for 20 consecutive samples using 10 ppm Na set to a reading of 50)Linearity: 2 % (when concentration of 3 ppm Na/K and 5 ppm Li are set to a reading of 100)Specificity:Interference from Na, K and Li equal in concentration to test element will be 0.5 %Recorder output:Nominal 1.00 V for a reading of 100.0Air:6 l/min at 1 Kg/cm2 /14psi (oil and moisture free pressurised air)Dimensions (W x D x H): Weight:420 x 360 x 300 mm 8 kgPower supply:190 ... 250 V, 50/60 Hz

Flame Photometers FP8000 series
Even the lowest concentrations of alkali and alkaline earth elements in aqueous solutions can be determined cost-effectively and user-friendly. Simultaneous measurement of the elements Na, K, Ca and Li in the laboratory and process analysis (others on request). Thanks to proven measuring methods and modern instrument electronics, the flame photometers achieve precise and reproducible measurement results in a matter of seconds with maximum operational reliability. Suitable for individual measurements, fully automatic measuring operation, continuous operation and use as a process instrument.Economic, user-friendly and durable solution for use in laboratory and process operationSimultaneous measurement of up to four alkaline and alkaline earth elements, depending on model up to 300 measurements per hourMaximum operational safety through intelligent security mechanismsSimple operation through touch screen and intuitive softwareTo use with Popan/Butan (alkaline elements) and Acetylene (alkaline earth elements)Interfaces: 2 x USB, 1 x Ethernet, 1 x RS-232 for printer, FP8500 additionally: Upgrade 4 to 20 mA analogue, passive current interfaceCompliance with international norms and standardsSpecificationsMeasuring ranges: Na/K/Li Ca 0,01 ... 4500 ppm 0,50 ... 4500 ppmCalibration:Linear with 2 standards Not-linear with 6-8 standards, cubic approximationDrift:1 % in 60 minReference:Lithium guideline with 5 mmol/l Cäsium guideline on request

Flow-through cells with two optical paths lengths, Absorption and Fluorescence Measurement
Wavelength Range: 200nm - 2500nmOptical material: Quartz glass High Performance* For fluorescence measurement

Hand spectroscopes
Handy and precise. Angle dispersion C -F: 7°. Linear dispersion: 60 mm (direct vision prism of Amici type)Ideal for demonstrations in schools and for:Viewing / observation of emission and absorption spectraControl of the wavelength spectra of gas emission lamps

HELLMANEX® III liquid
Cleaning:HELLMANEX® III is an alkaline liquid concentrate used for the highly effective cleaning of glass or silica cells and other sensitive optical components. Laboratory equipment made of glass, quartz, sapphire and porcelain can also be cleaned using the solution.Characteristics:Hellmanex® III significantly reduces the surface tension of water. The removal of dirt particles is also assured by the good wetting action of a Hellmanex® III aqueous solution, whilst its high emulsifying and dispersing capabilities prevent the re-deposition of the loosened particles. Special surface-active substances facilitate the residue-free rinsing of the optical components once they have been cleaned.Cleaning and Dilution:The optimal dilution depends on several factors, such as the hardness of the water, the degree and type of contamination, the temperature, etc. The use of demineralised water improves the cleaning characteristics.Available in 1.3kg PE-bottle.The following treatments have been proven at a concentration (vol%) 0.5 to 2 in practice.Temperature°CTime minutes20-25120-18030-3530-4050-60 (quartz only)10-1570-80 (quartz only) 5
Holder for Absorption Cells
Cuvette holder fits 6.201 271, 6.204 502, 6.201 331 and 6.203 069 for absorption measurements in the UV range, with loose window panels, External dimensions (W x H x D) 45 x 12mm , 5mm x 12.5mm


LLG-Cuvette rack, PP
Ideal for storing up to 16 cuvettes with 10 mm width. Two-tier arrangement of the cuvette rows ensures clarity.Numbered positionsAutoclavable at 121 °C

LLG-Cuvettes
LLG-Cuvettes are most frequently used in analytical laboratories.They have two clear windows, two side walls and are available as optical glass or quartz variants. The walls and the base are polished inside and frosted outside. The thickness of the windows and the base is 1.25 mm. The overall height of standard type cells is 45 mm or 48 mm for those fitted with a stopper. Each cuvette is supplied with a PTFE lid.Optical Glass: 335 to 2500 nmQuartz: 200 to 2700 nm

LLG-Disposable plastic cells, PS
The shape and narrow wall thickness of the cuvettes enable an excellent heat transfer resulting in constant sample temperatures during photometric measurements.Cavity sortedGlass clear polystyrene (PS)Applicable wavelength range 340 nm to 900 nmVery low variation of extinction valuesExcellent optical transmission rangePath length 10 mmOverall dimensions 12.5 mm x 12.5 mm x 45 mmStyrofoam racks: 100 cuvettes in a styrofoam box with cover

Lovibond® Comparator 2000+
Lovibond® Comparator 2000+ is a quality instrument for the visual analysis of colour intensity in analysis samples using Lovibond colour discs. The integral cell attachment enables cells with a depth of 40mm to be accepted. The Lovibond® Nessleriser system provides greater depths by using corresponding accessory Nessler tubes. This enables the determination of concentrations below the detection limit of the Lovibond® Comparator 2000+. The integral prism in the Lovibond® Comparator 2000+ brings the glass standard of the colour discs and the colour samples optically into the field of view. The prism is hermetically sealed, preventing the lens from being contaminated. Both the Comparator 2000+ and the Nessleriser are designed in such a way that they compensate for cloudy or coloured water samples. Each device is available for use in daylight or in combination with the artificial daylight unit 2000.

Lovibond® Comparator 3000
Visual comparators for colour grading. A series of 3-field instruments designed for visual colour grading by direct comparison between the sample and coloured glass standards. The sample and two adjacent glasses on the colour scale are viewed simultaneously, making it easier to achieve the optimum colour match. The tungsten halogen light source is colour corrected to CIE Standard Illuminant C (B for the EBC Comparator 3000) and guarantees constant lighting conditions for colour grading. Versions of the Comparator 3000 are available for the following scales, each supplied with the appropriate range of colour standards and sample containers:TypeTypical ApplicationsGardner Comparator 3000:Chemicals and oils including resins, varnishes, drying oils and fatty acids (ASTM D1544; ISO 4630, AOCS Methods Ja 9-87, Td 1a-64, Td 3a-64).Petroleum Oils Comparator (AF 650):Petroleum oils and fuels (ASTM D1500; IP 196; DIN 51 578; ISO 2049; BS 5859)EBC Comparator 3000:Beers, malt worts, caramels and similarly coloured liquids (Analytica)

Lovibond® Nessleriser Systems, Pt-Co/Hazen/APHA Scale
Lovibond® Comparator 2000+ is a quality instrument for the visual analysis of colour intensity in analysis samples using Lovibond colour discs. The integral cell attachment enables cells with a depth of 40mm to be accepted. The Lovibond® Nessleriser system provides greater depths by using corresponding accessory Nessler tubes. This enables the determination of concentrations below the detection limit of the Lovibond® Comparator 2000+. The integral prism in the Lovibond® Comparator 2000+ brings the glass standard of the colour discs and the colour samples optically into the field of view. The prism is hermetically sealed, preventing the lens from being contaminated. Both the Comparator 2000+ and the Nessleriser are designed in such a way that they compensate for cloudy or coloured water samples. Each device is available for use in daylight or in combination with the artificial daylight unit 2000.ModelApparatus includedAF 325:Nessleriser 2150 with Daylight 2000 Lighting Unit and 113 mm (50ml) Nessler cylinders, Pt-Co discs NSH (10 to 90mg Pt/l), NSB (70 to 250mg Pt/l), stand for using Nessleriser with natural light.AF 328:Nessleriser 2250 with Daylight 2000 Lighting Unit and 250mm Nessler cylinders, Pt-Co discs CAA (0 to 30mg Pt/l), CAB (30 to 70mg Pt/l), stand for using Nessleriser with natural light.AF 329:Nessleriser 2150 with Daylight 2000 Lighting Unit and 113mm (50ml) Nessler cylinders, Nessleriser 2250 upgrade with 250mm Nessler cylinders, Pt-Co discs CAA (0 to 30mg Pt/l) CAB (30 to 70mg Pt/l), NSB (70 to 250mg Pt/l), stand for using Nessleriser with natural light.AF 330:Comparator 2000+ with Daylight 2000 Lighting Unit (EBC Version), EBC discs (4/14A, 2 - 6; 4/14B, 6 - 10; 4/14C, 10 - 18; 4/14D, 19 - 27), 2 x W680/OG/25 mm fused cellsAF 334:Comparator 2000+ with Daylight 2000 Lighting Unit, Gardner discs (4/30 AS, 1 - 9; 4/30 BS, 10 - 18), 2 x W680/OG/10 mm fused cells

Macro cells for absorption measurement, NIR-range, quartz glass Extended Range
Quartz glass Extended Range, Wavelength range: 200 - 3500 nm. Inside width 9.5 mm. Base thickness 1.5 mm.Type A: with PTFE lid Type B: with small glass lidType D: with PTFE stopper / from 40 mm with 2 PTFE stoppers

Macro cells for absorption measurement, UV-range, quartz glass High Performance
Quartz glass High Performance 200 - 2500 nm. Inside width 9.5 mm. Base thickness 1.5 mm.Type A: with PTFE lidType B: with small glass lidType C: with regular glass lidType D: with PTFE stopper / from 40 mm with 2 PTFE stoppers

Macro cells for absorption measurement, VIS-range, special optical glass
Special optical glass 320 - 2500 nm. Inside width 9.5 mm. Base thickness 1.5 mm.Type A: with PTFE-FalzdeckelType B: with small glass lidType C: with regular glass lid

Macro cuvettes
Sorted by mold cavity number to ensure lowest variation of extinction coefficient. Optically perfect transmission range. Manufactured under controlled room conditions and packaged fully automatically. CERTIFIED LIFE SCIENCE QUALITY.Sorted by mold cavity number to ensure lowest variation of extinction coefficient. Optically perfect transmission range. Manufactured under controlled room conditions and packaged fully automatically. CERTIFIED LIFE SCIENCE QUALITY.

Macro cuvettes, plastic
For photometric measurements even in the UV range.Applicable wavelength range 220 to 900 nmLow variation of extinction valuesGood optical transmission rangeSorted by mould cavity numberScope of supply: 100 netidentical cuvettes in styrofoam box with a resealable cover

Macro cuvettes, with 4 optical windows, PS
Sorted by mold cavity number to ensure lowest variation of extinction coefficient. Optically perfect transmission range. Manufactured under controlled room conditions and packaged fully automatically. CERTIFIED LIFE SCIENCE QUALITY.Particularly suitable for fluorescence spectroscopy.

Macro cuvettes, with 4 optical windows, UV-transparent
Sorted by mold cavity number to ensure lowest variation of extinction coefficient. Optically perfect transmission range. Manufactured under controlled room conditions and packaged fully automatically. CERTIFIED LIFE SCIENCE QUALITY.Particularly suitable for fluorescence spectroscopy. The UV version can be used from a wavelength of 230 nm and shows minimal autofluorescence.