Micro plates, quartz glass
96-well-plates. Quartz glass, with synthetic quartz glass base. Ideal for use with aggressive media, for UV-range measurements, in microscopy, or in fluorescence studies.

Micro Volume Analysis TrayCell
Fibre-Optic Micro Measuring Cell. Accessory for standard spectrophotometer for droplet analysis.Sample volume 0.7µl to 10µl.Typical applications are:nucleic acid analysis.determination of the incorporation frequency of fluorescent dye labels (FOI).protein analysis (A280, BCA, Lowry etc.).all UV / Vis analysis utilising wavelength range 190nm to 1100nm.material: Quartz glass High Performance.Please state the required cell centre height (8.5mm, 15mm or 20mm) when placing your order! TrayCell is supplied as standard with caps for both 0.2mm and 1mm light path. Additional light path of 0.1mm and 2mm are available.

Micro volume measuring cell TrayCell 2.0
Fibre-optic micro volume measuring cell for UV/VIS-based microvolume analysis. Suitable for all current spectrophotometers with standard cuvette holder.Purity and concentration determination of DNA/RNA and proteinsDetermination of labelling efficiency for microarray experimentsPrecisely defined path lengths prevent misadjustmentRecovery of samples by simple pipetting offSamples with low surface tension can be measuredQuick and easy cleaningPlease indicate the centre height when placing your order!Scope of supply: Cuvette, lid for the indicated layer thicknessesSpecificationsVolume:0.7 ... 10 µlMeasuring range:210 ... 1100 nmWindow material:High performance quarz glassDimensions (W x D)

Microplate spectrophotometer INNO
Microplate spectrophotometer with monochromator-based optical system. Wavelengths can be freely selected without changing filters. Suitable for spectral scanning, endpoint measurements, kinetic measurements, and scanning of well areas.Measurements in 6 to 384 well microplatesVarious quantitative and qualitative assay tests available7 different regressions to analyse dataUp to 6 wavelengths can be set in the endpoint/kinetic settingsClear user interfaceMonochromator-based UV/Vis absorbanceMicrovolume measurements for quantification of nucleic acids possible with nano volume plate. Please order separately.Detection system:PhotodiodeWavelength range:200 ... 999 nmDynamic range:0 ... 4.0 ODDynamic accuracy:0 ... 2 OD ±1 %Dynamic repeatability:0 ... 2 OD ±1 %Dynamic linearity:0 ... 2 OD ±1 %Light source:Xenon lamp

Microplate spectrophotometer INNO-M
Microplate spectrophotometer with monochromator-based optical system. Wavelengths can be freely selected without changing filters. Suitable for spectral scanning, endpoint measurements, kinetic measurements, and scanning of well areas.Measurements in 6 to 384 well microplatesVarious quantitative and qualitative assay tests available7 different regressions to analyse dataUp to 6 wavelengths can be set in the endpoint/kinetic settingsClear user interfaceMonochromator-based UV/Vis absorbanceWith luminescence detectionMicrovolume measurements for quantification of nucleic acids possible with nano volume plate. Please order separately.Detection system:Photodiode (absorbance), photomultiplier (luminescence)Wavelength range:200 ... 999 nm (absorbance), 300 ... 700 nm (luminescence)Dynamic range:0 ... 4.0 ODDynamic accuracy:0 ... 2 OD ±1 %Dynamic repeatability:0 ... 2 OD ±1 %Dynamic linearity:0 ... 2 OD ±1 %Light source:Xenon lamp

Microplate spectrophotometer INNO-S
Microplate spectrophotometer with linear and orbital shaking mechanism for versatile measurements of microplate-based assays.Suitable for 6 to 384 well microplatesIncubation of microplates up to 50 °CINNO-X software for data evaluationUSB and RS232 interfaceMonochromator-based UV/Vis absorbanceLuminescence and filter-based fluorescence detection for TRF assaysSuitable for spectral scanning, endpoint measurements, kinetic measurements, and scanning of well areasMicrovolume measurements for quantification of nucleic acids possible with nano volume plate. Please order separately.YFP fluorescence filter (481 nm EX) and TRITC fluorescence filter (543 nm EX) are included in the scope of supply. Further fluorescence filters available on request.Detection system:Photodiode (absorbance), photomultiplier (luminescence + fluorescence)Wavelength range:200 ... 999 nm (absorbance), 190 ... 720 nm (luminescence), 350 ... 700 nm (fluorescence)Dynamic range:0 ... 4.0 ODDynamic repeatability:0.5 % at 2.0 ODDynamic linearity:1 % (0 ... 3.0 OD)Light source:Xenon lamp (absorbance), LED (fluorescence)Incubation temperature:Max. 50 °CTemperature accuracy:±0.2 °C at 37 °C

Microplate spectrophotometer INNO-SA
Microplate spectrophotometer with linear and orbital shaking mechanism for versatile measurements of microplate-based assays.Suitable for 6 to 384 well microplatesIncubation of microplates up to 50 °CINNO-X software for data evaluationUSB and RS232 interfaceMonochromator-based UV/Vis absorbanceSuitable for spectral scanning, endpoint measurements, kinetic measurements, and scanning of well areasMicrovolume measurements for quantification of nucleic acids possible with nano volume plate. Please order separately.Detection system:PhotodiodeWavelength range:200 ... 999 nmDynamic range:0 ... 4.0 ODDynamic repeatability:0.5 % at 2.0 ODDynamic linearity:1 % (0 ... 3.0 OD)Light source:Xenon lampIncubation temperature:Max. 50 °CTemperature accuracy:±0.2 °C at 37 °C

Microplate spectrophotometer INNO-SF
Microplate spectrophotometer with linear and orbital shaking mechanism for versatile measurements of microplate-based assays.Suitable for 6 to 384 well microplatesIncubation of microplates up to 50 °CINNO-X software for data evaluationUSB and RS232 interfaceLuminescence and filter-based fluorescence detection for TRF assaysMicrovolume measurements for quantification of nucleic acids possible with nano volume plate. Please order separately.YFP fluorescence filter (481 nm EX) and TRITC fluorescence filter (543 nm EX) are included in the scope of supply. Further fluorescence filters available on request.Detection system:Photomultiplier (luminescence + fluorescence)Wavelength range:190 ... 720 nm (luminescence), 350 ... 700 nm (fluorescence)Light source:LED (fluorescence)Incubation temperature:Max. 50 °CTemperature accuracy:±0.2 °C at 37 °C

Microplate washer CAPPWash
The microplate washer is ideal for small scale work. It can be purchased individually or as a set, including all components necessary for the set up. The Two-in-One Design of Capp elisa plate washer offers two functions: add the washing solution to the well and aspiration of the used solution back to the waste collection bottle.Produced from stainless steel and polypropyleneResistant to aggressive chemicals

Microplate washer INNO-W96
The microplate washer with large 7" touch display is suitable for washing 96-well microplates. The 96 pins of the wash head can be controlled in a single row. The wash head has two-point aspiration and performs bottom flushing. A liquid level sensor automatically recognises the liquid level and alarms if the cleaning liquid is insufficient and the waste liquid overflows. Numerous washing parameters can be set via the user-friendly operating system, such as number of washing processes, amount of wash solution, as well as soaking and shaking time. The plate washing process ends automatically.4 plate types (V-, U-, flat, and round bottom) selectable2 kinds of automatic washing adjustable to reduce interference adsorption during reactionUp to 200 wash programmes

Mini cell washer, Vakuwasch
PE construction. Practically unbreakable. Glass cuvettes are washed and dried in a few seconds during one operating cycle, using a simple process. All that is required is a filter flask (with pierced rubber bung, 13 mm hole and pressure tubing) and a slight vacuum.

Nano volume plate Nano-VC for microplate spectrophotometer INNO
Plate for holding a 24-well microtitre plate with 2 µl sample volume. Suitable for nucleic acid quantification up to 2 ng/µl dsDNA. With slot for a 2.5 ml cuvette with 0.5 mm path length.
Nessler cylinders, Soda-lime glass
With spout and white circular mark. Calibrated "In".

Nessler tubes for Lovibond® Comparator System 2000
Nessler cylinder AF306P, 113 mm: For use with the Nessleriser 2150 for the measurement of the Pt-Co/Hazen colour discs NSH (10-90 mg Pt/l) and NSB (70-250 mg Pt/l) and NSX (50-300 mg Pt/l).Nessler cylinder DB420, 250 mm: For use with the Nessleriser 2250 for the measurement of the Pt-Co/Hazen colour discs CAA (0-30 mg Pt/l) and CAB (30-70 mg Pt/l).


Plastic disposable UV cuvettes, micro
For photometric determination of proteins, ssDNA, dsDNA, RNA and oligonucleotides in the UV range. Sample volumes as small as 70 µl are sufficient.Usable for wavelengths from 230 nmFor measurements at 260 nm, 280 nm and in the visible rangeGrouped by mold cavity number

Plastic disposable UV cuvettes, micro, individually wrapped
For photometric determination of proteins, ssDNA, dsDNA, RNA and oligonucleotides in the UV range. Sample volumes as small as 70 µl are sufficient.Usable for wavelengths from 230 nmFor measurements at 260 nm, 280 nm and in the visible rangeFree of DNase, DNA and RNaseGrouped by mold cavity number

Polarimeter ADP430
General purpose single wavelength polarimeter for applications in the sugar, food, chemical, and pharmaceutical industry. Measurements can be performed in angular degrees (°A), sugar (ISS), or user-defined scales. Pre-programmed methods (e.g. PHR-MEAN method, invert sugar, inversion (A-B), and specific rotation) simplify the performance of routine analyses.High-resolution 4" HD colour displayLED light sourceInterference filter with photodiode detector technologyContinuous measurement and single measurementRFID user identificationData memory for over 8000 readingsMeasurement up to an optical density of 3.0Output as secure PDF possibleUSB (A), USB (B), and Ethernet interfaceSupports FDA Regulation 21 CFR Part 11USP/EP/BP compliantSuitable for applications where internal temperature control is not required, the use of automatic temperature compensation is used, or a water bath is preferred.

Polarimeter ADP450
General purpose single wavelength polarimeter for applications in the sugar, food, chemical, and pharmaceutical industry. Measurements can be performed in angular degrees (°A), sugar (ISS), or user-defined scales. Pre-programmed methods (e.g. PHR-MEAN method, invert sugar, inversion (A-B), and specific rotation) simplify the performance of routine analyses.High-resolution 4" HD colour displayLED light sourceInterference filter with photodiode detector technologyContinuous measurement and single measurementRFID user identificationData memory for over 8000 readingsMeasurement up to an optical density of 3.0Output as secure PDF possibleUSB (A), USB (B), and Ethernet interfaceSupports FDA Regulation 21 CFR Part 11USP/EP/BP compliantPatented, integrated Peltier temperature control systemSMART temperature stability

Polarimeter ADP450-HCl
General purpose single wavelength polarimeter for applications in the sugar, food, chemical, and pharmaceutical industry. Measurements can be performed in angular degrees (°A), sugar (ISS), or user-defined scales. Pre-programmed methods (e.g. PHR-MEAN method, invert sugar, inversion (A-B), and specific rotation) simplify the performance of routine analyses.High-resolution 4" HD colour displayLED light sourceInterference filter with photodiode detector technologyContinuous measurement and single measurementRFID user identificationData memory for over 8000 readingsMeasurement up to an optical density of 3.0Output as secure PDF possibleUSB (A), USB (B), and Ethernet interfaceSupports FDA Regulation 21 CFR Part 11USP/EP/BP compliantPatented, integrated Peltier temperature control systemSMART temperature stabilityGlass/PEEK polarimeter tubeSuitable for tests with hydrochloric acid

Polarimeter ADP600 series
High-precision polarimeter with Peltier temperature control for applications in pharmacy, chemistry, food industry, and research. Pre-programmed methods (e.g. concentration, invert sugar, inversion (A-B), and specific rotation) simplify the performance of routine analyses.High-resolution 7.4" LCD touchscreenSimple menu structure with a method systemRFID user identificationUV/VIS lamp with narrow band filterSuitable for standard and low volume tubesUSB (A), USB (B), RS232, and Ethernet interfaceSupports FDA Regulation 21 CFR Part 11USP/EP/BP/JP compliant

Polarimeter AP-300
Model AP-300 is generally used in pharmaceutical, perfume, cosmetic, industrial, chemical, and food factories and is the optimal unit for measuring angle of rotation. In addition, the built-in International Sugar Scale is widely used in sugar refineries.The AP-300 has a manual calibration facility which allows the user to compensate for any differences to standard liquids and measurement values by other standard instruments.