Imhoff sedimentation cones, SAN
For determination of suspended matter in liquids (e.g., for industrial and municipal wastewater). DIN 12 672With molded graduationsCircumferential scale lines at 10 ml and 100 mlScrew cap with an M14 threadWith labelling field

Imhoff sedimentation vessels, Nalgene®, PC
For the determination of sedimentable particles in water and waste water and for measuring the sand content in well water. With leak-proof polypropylene screw cap.TransparentAutoclavableGraduation steps 100 ml

Infrared rapid digestion system with temperature control
The temperature-controlled InKjel TC-series devices combine the advantages of infrared and block digestion in one system: Fast Infrared digestion at defined temperatures ensures high sample throughput.In the programmable version InKjel TCP, the user has a choice of 25 freely configurable programs for temperature and digestion time.The high-quality quartz infrared heaters of InKjel TC reach 830 ° C in a minute and achieve uniform heating at all sample positions.

InKjel M manually adjustable infrared digestion system
Rapid digestion system with manually adjustable energy control and direct heating of the samples through high-quality quartz radiators (1500W).Quartz infra-red radiators peak at 830°C within 1 min.Particularly uniform heating at all sample positionsAll InKjel systems are fitted completely with multi-level consoles, fume extraction unit, sample rack and glass digestion vessels.Configurations available:6 sample vessels each 250ml12 sample vessels each 100ml12 sample vessels each 250ml4 sample vessels each 500ml4 sample vessels each 750ml

InKjel P infrared digestion system with 10 freely configurable programmes
Rapid digestion system with 25 freely configurable programmes for power and digestion time and direct heating of the samples through high-quality quartz radiators (1500W).Quartz infra-red radiators peak at 830°C within 1 min.Particularly uniform heating at all sample positionsAll InKjel systems are fitted completely with multi-level consoles, fume extraction unit, sample rack and glass digestion vessels.Configurations available:6 sample vessels each 250ml12 sample vessels each 100ml12 sample vessels each 250ml4 sample vessels each 500ml4 sample vessels each 750ml
Karlsruher Bottle KF 12 with Stopper NS 19
To use with dissolved oxygene sensors, e.g. FDO® 925 or CellOx® 325. Bottles of 250 ml.

Laboratory turbidimeter TB 300 IR
Turbidity is measured according to ISO 7027 by nephelometric means (90° scattered light). The infra-red light-source permits measurement of coloured and colour-free samples. The automatic measurement range detection facility (Autorange) enables direct turbidity measurement from 0.01 to 1100 NTU.Automatic overall range adjustment with standard set T-CalHigh accuracySuitable for laboratory and mobile useMemory storage of up to 1000 data-setsReal-time clockWaterproof sample chamber and housingScope of supply: Turbidimeter TB 300 IR in carrying case, 1 set of turbidity standards T-Cal, 7 rechargeble batteries (AA), 1 lithium battery, main charger 100-240V, PC connection cable, 4 vials (diam. 24 mm) with lids, instruction manualSpecificationsLight source:IR-LED (860nm)Keypad:acid and solvent resistant, membrane switch keypadAuto - Off:automatic switch off approx. 20 min after last key pressDisplay:Graphic-displayUpdate:Software update via internetMemory:1000 data sets with date, time and registration no.Measuring range:0.01 to 1100NTU (Auto range)Resolution:0.01NTU (0.01 to 9.99NTU) 0.1NTU (10 to 99.9NTU) 1NTU (100 to 1000NTU)Accuracy:± 2% of measured value or 0.01 (0 to 500NTU)/± 5% of measured value (500 to 1100NTU)Ambient conditions:0 to 40°C at 30 to 90% R.H. (non condensing)Interface:RS232Power supply:7 NiMH rechargeable batteries (AA/Mignon), wall plug mains adapter and Lithium battery for data storage and real time clock

LabStation
LabStation with LSdata software for easy data evaluation. The rechargeable battery is included in the delivery.direct export to MS-ExcelGLP-conform data transfercalibration curve calculationadjustment between meter and PC


LLG-Extraction thimbles, cellulose
Neutral and fat free. With excellent retention capacity. Ash content <0.1 %.

Lovibond® water testing equipment
Single-parameter and multi-parameters kits, including for chlorine and pHThe Lovibond® product range contains a large selection of single and multi-parameter water testing equipment. Each kit is a complete, portable system that guarantees accurate water tests and contains all of the colour discs, reagents, accessory parts and detailed instructions necessary for the respective tests ensuring that reliable results may be obtained. The table below illustrates the most popular water testing kits. In addition, kits can also be created in accordance with specific user requirements on request.All test apparatus for parameters listed against individual kits are supplied.
Measuring bottles for BOD measurement system OxiTop®
Iincl. 2 x nozzles, 2 x VS25 screwing sets for nozzle, 1 x GK 600 rubber sleeve, 2 x SEP25 septum for nozzle, 2 x STH25 support for nozzle

Measuring heads OxiTop®-i, 1 measuring head
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsMenu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readings

Measuring heads OxiTop®-i, 12 measuring heads
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 6 x measuring head grey, 6 x measuring head blue

Measuring heads OxiTop®-i, 2 measuring heads
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 1 x measuring head grey, 1 x measuring head blue

Measuring heads OxiTop®-i, 2 measuring heads Set 2
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 1 x measuring head grey, 1 x measuring head blue, 2 sample bottles, 2 rubber quivers, 2 magnetic stirring rods

Measuring heads OxiTop®-i, 6 measuring heads
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 3 x measuring head grey, 3 x measuring head blue

Measuring heads OxiTop®-i, 6 measuring heads Set 6
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 3 x measuring head grey, 3 x measuring head blue, 6 sample bottles, 6 rubber quivers, 6 magnetic stirring rods
Measuring vessels for BOD measuring system OxiTop®
Incl. 1 x DV/MG lid adapter with rack, gasket, 2 x GK 600 rubber sleeves, 4 x DV/MG/KL clamps, 1 x MB 50 measuring beaker (50 ml)

Micro Kjeldahl block digestion systems K 16, K 24 and K 40
Block digestion systems with high-quality corrosion-resistant block housing made of stainless steel. With 16, 24 or 40 sample slots for micro Kjeldahl digestion vessels with a volume of 100 ml. High-efficiency heating and extraction hood with exhaust collector.behr single-knob control for particularly easy and fast programming.Menu navigation in national language.25 freely configurable programs for block temperature and digestion time.Applications can be saved.USB interface.The removable inspection door on the insertion rack enables the progress of the digestion to be observed.Complete systems with digestion vessels, rack and extraction hood.

Microbiological Air Sampling System MBASS30V3
Compact sampling system for various sampling methods e.g. air sampling on standard petri-dishes with the air sampling heads LKS 30 (30 l/min) and LKS100 (100 l/min) and the total spore content on slides with the particle collector PS 30 (30 l/min).Anodised aluminum housing with two tripod threadsBattery operation up to 22,000 liters of sampling air with one chargeElectronic volume flow control from 30 l/min up to 100 l/minSampling volumes preselectable from 10 to 10,000 litresStart delay up to 24 hours can be activatedIlluminated 4.3 inch colour display with touch operationIntegrated temperature sensorRing buffer for data of the recent 100 samplingsUSB interfaceDimensions (W x D x H): 180 x 255 x 160 mm without sampling headLKS 30 and LKS100 are validated in accordance with EN ISO 14698-1Scope of delivery: MBASS30V3 base device, quick-charger, manual, USB connection cable, MBASSControl software
Milk analyser LactoFlash
Analyser with printer, for the rapid and accurate determination of Fat and SNFDensity, protein, lactose and freezing point are calculatedFat:0.00 ... 40.00 %SNF:0.00 ... 15.00 %