Stoppers, EPDM, for butyrometers
Made of ethylene propylene diene monomer rubber.

Test Kits for Boiler-, Cooling- and Industrial Process Water
These test kits are specially developed for testing boiler, cooling and industrial process water. They make use of both colorimetric and titrimetric techniques. Each test kit contains all the necessary chemicals and reagents in liquidor powder form to conduct the tests. The detailed instructions contain a step-by-step explanation of the test procedure. The kits are supplied in a sturdy, compact plastic case.Fast quantitative determinationFor testing boiler, cooling and industrial process waterSuitable for field and laboratory testingCost-effective use due to keenly priced refill packs

Test kits, VISOCOLOR®alpha for water analysis
All test kits are qualified for the analysis of seawater. VISOCOLOR® alpha is the most simple version of colorimetric and titrimetric test kits. These tests are suitable for visual evaluation only and are very convenient in performance, because of the multicomponent reagents used.* Not suitable for analysis of seawater.

Test kits, VISOCOLOR®ECO for water analysis
All test kits are qualified for the analysis of seawater. VISOCOLOR® ECO presents a product group of colorimetric and titrimetric test kits, which allow even the determination of low limiting values with sufficient accuracy. The high sensitivity and accuracy is accomplished by single reagents which can be dosed precisely and by the possibility to compensate turbidity and color of water samples.* Not suitable for analysis of seawater.

Test kits, VISOCOLOR®ECO for water analysis, refill pack
All test kits are qualified for the analysis of seawater.

Test kits, VISOCOLOR®HE for water analysis
All test kits are qualified for the analysis of seawater.* With titration equipment, the measuring range can be extended by additional syringe fillings.

Test kits, VISOCOLOR®HE for water analysis, refill pack
All test kits are qualified for the analysis of seawater.* With titration equipment, the measuring range can be extended by additional syringe fillings.

Test papers, potassium iodide starch
This test paper allows the quick and easy detection of strong oxidizers such as nitrite and free chlorine. Potassium iodide starch paper is also used to control diazotization reactions. Nitrite or free chlorine oxidize potassium iodide to form elemental iodine which reacts with starch to a blue-violet complex. Potassium iodide starch paper may be used by dipping it into the sample or by applying drops of the sample onto the paper. To detect gaseous oxidizers, the paper is moistened with distilled water and then exposed to the gas in question.

Test strips Chem-QUANT®
Reliable and preciseNon-bleedingEasy and quick analysisMade in Europe

testo Cooking oil temperature Set BT
Set consisting of cooking oil tester testo 270 BT and penetration/infrared thermometer testo 104-IR BT. Ideal for food control measurements.The cooking oil tester enables simple, fast, and reliable monitoring of cooking oil quality.With the penetration/infrared thermometer testo 104-IR BT, the surface and core temperature of food can be measured quickly and easily.Scope of supply: Cooking oil tester, penetration/infrared thermometer testo 104-IR BT, transport case, reference oil for cooking oil tester, training card testo 270 BT and testo 104-IR BT, calibration protocols, instruction manuals, AAA batteries

Thermoreactor CR 2200
Routine device for waste water analysis. Thermoreactor with preset programmes for the digestion of standard parameters in reaction cuvettes. The CR2200 allows standard-compliant digestion with programmes for the standard parameters COD, total nitrogen, total phosphorus, TOC and heavy metals in galvanisation.1 thermoblock with 12 holes for reaction cells with an outer diameter of 16 mm8 stored programmes for all important digestions: 148 °C for 120 min; 148 °C for 20 min; 120 °C for 30 min; 120 °C for 60 min; 120 °C for 120 min; 150 °C for 120 min; 100 °C for 60 min, 100 °C for 30 minAutomatic temperature switch-off at the end of the set programmePower supply 115/230 VAC, 50/60 Hz

Thermoreactor CR 3200
Thermoreactor with pre-programmed and user-defined programmes for the digestion of standard parameters in reaction cuvettes. The CR3200 allows standard-compliant digestions with programmes for the standard parameters COD, total nitrogen, total phosphorus, TOC and heavy metals in galvanisation. In addition, 8 separate programmes can be created for special digestions at temperatures between room temperature (25 °C) and 170 °C.2 thermoblocks with 12 holes each for reaction cells with an outer diameter of 16 mm8 stored programmes for all important digestions: 148 °C for 120 min; 148 °C for 20 min; 120 °C for 30 min; 120 °C for 60 min; 120 °C for 120 min; 150 °C for 120 min; 100 °C for 60 min, 100 °C for 30 minAutomatic temperature switch-off at the end of the set programmeAQA/IQK with optional external temperature sensor for documentationPower supply 115/230 VAC, 50/60 Hz

Thermoreactor CR 4200
Thermoreactor with pre-programmed and user-defined programmes for the digestion of standard parameters in reaction cuvettes. The CR4200 allows standard-compliant digestions with programmes for the standard parameters COD, total nitrogen, total phosphorus, TOC and heavy metals in galvanisation. In addition, 8 separate programmes can be created for special digestions at temperatures between room temperature (25 °C) and 170 °C. Independent thermoblocks allow 2 different programmes to be run simultaneously.2 independent thermoblocks with 12 holes each for reaction cells with an outer diameter of 16 mm8 stored programmes for all important digestions: 148 °C for 120 min; 148 °C for 20 min; 120 °C for 30 min; 120 °C for 60 min; 120 °C for 120 min; 150 °C for 120 min; 100 °C for 60 min, 100 °C for 30 minAutomatic temperature switch-off at the end of the set programmeAQA/IQK with optional external temperature sensor for documentationPower supply 115/230 VAC, 50/60 Hz

Thermoreactor RD 125
Chemical digestion of samples is required for the photometric determination of COD, TOC, total chromium, total phosphate and total nitrogen. The required temperatures and reaction time can be selected by using the membrane keypad of the reactor RD 125. The unit works at three different temperatures (100 / 120 / 150 °C) and three pre-set reaction times (30 / 60 / 120 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm. The RD 125 reactor is fitted with 24 holes for 16 mm diameter vials.SpecificationsPower supply:230 V / 50-60 Hz or 115 V / 50-60 Hz (switchable)Power:550 WDimensions:248 x 219 x 171 mmWeight:3.9 kgHoles in the aluminium block:24 holes, 16.2 mm ± 0.2 mmSelectable temp.:100 / 120 / 150 °CSelected time:30 / 60 / 120 / min. and continuous operation (∞)Heating up:from 20°C to 150°C in 12 min.Protection against overheatingBeeperEnvironmental conditions:10 - 40 °C max. 85 % rel. humidity

Thermostat LT200
For easy, reproducible sample digestion. With 2 separately controlled heating blocks and separate protective hoods. Automatic switch-off with acoustic signal. Programmed for all standard methods, own digestion methods can be defined by the user.3 presets and 6 user-defined methods programmableIlluminated digital display for remaining time, temperature and user guidanceWith overheating protection and insulated housingSpecificationsHoles:Left block 15x13 mm, right block 6x13 mm and 4x20 mmTemperature range:37...150 °CTemperature accuracy:±1 °CDigestion time:1...480 min.Permissible ambient temperature:10...45 °CMax. humidity:90 % r.F.Dimensions (W x D x H):250 x 310 x 145 mmWeight:2.8 kgPower supply:115...230 V, 50/60 Hz

Thermostatic cabinets TC, with glass door
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubatorThe incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubator

Thermostatic cabinets TC, with steel door
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubatorThe incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubator
Titration apparatus STANDARD
For the determination of acid content to ascertain the degree of freshness.Complete with storage bottle, rubber stopper, burette with automatic zero point adjustment, soda lime tower with ascending tube, rubber pressure bulb, burette tip with pinchcock, one 1 ml and one 25 ml pipette, one 200 ml Erlenmeyer flask

TRS 300 programmable temperature and time control unit
Programmable control unit for behrotest® digester blocks.behr one-button operation for particularly easy and quick programming. Menu navigation in the language of the country. 10 optionally configurable programs for block temperature and digestion time.The TRS 300 has a special COD program which has already been set by the plant. Therefore in the operation mode "COD" it heats up to a temperature which is 20°C above the set target temperature. After inserting the samples, the 20°C higher target value remains for another 6 minutes. This procedure ensures heating up to 148°C within 10 minutes which is specified by the ISO norm, and at the same time causes extremely high temperature constancy during the subsequent reaction process. The supplied Windows software permits the user to transfer time/temperatures profiles, which are specifically for the application, via the RS232 interface in both directions between one or more units (TRS 300) and a PC. Temperature data can also be transmitted from the unit to the PC via the RS232 interface while operating. The user can save them if necessary and print them out as graphics. Integrated safety function switches the connected units off if there is a short-circuit and an interruption of the temperature sensor.

Tube tests NANOCOLOR® Aluminium
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.

Tube tests NANOCOLOR® Ammonium
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.

Tube tests NANOCOLOR® anionic surfactants
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.

Tube tests NANOCOLOR® AOX 3
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.

Tube tests NANOCOLOR® BOD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.