Laboratory autoclaves D-line
The features of the laboratory autoclave line are specifically designed for most common laboratory applications and can be used for the sterilzation of liquids, instruments, glass, waste and for the preparation of nutrient media.EL = horizontal loadingELV = vertical loadingEL-CGD and ELV-CGD = with integrated steam generator and rapid coolingStores the last 200 cycles in built-in memoryOption: second flexible Pt 100 probe30 Identification Codes and Passwords for access level controlThe controller and software comply with the 21 CFR part 11 standardFilter replacement notifications based on the number of cyclesData archiving via USB interfaceDouble sterilization time monitoringIn/Out test (enables technicians to check each system component separately)Sterilization temperature range up 105 °C to 137 °COptional Disinfection/Isothermal Temperature range from 60°C to 105°C7 standard sterilisation programsOptions available Fast cooling technology and ventilator to reduce cooling time additionallyVacuum pump to evacuate residual airExhaust air filtrationLifting device to elevate/to lower heavy sterilzation goodsPrinter to document the performed cycle (Please order separately)R.PC.R software allows complete control and monitoring of the autoclave

Multiparameter Indicator 3M™ Comply™
Class 4 indicators with endpoint reaction. With chemical coating, change their colour when the sterilization cycle is successfully completed. Indicator strips for steam sterilization or ethylene oxide sterilization.Steam sterilization colour change from yellow to blackEO sterilization colour change from red to greenEconomical due to the possibility of cutting in halfComplies with EN ISO 11140-1

Roll dispenser with Cutter
The dispenser frame is made of stainless steel and steel rods with nylone bearings for hygienic use at CSSDs. The integrated cutting unit includes an accurate and high quality cutting blade, providing safe and secure handling, as well as easy replacement. The roll dispenser and cutter is an useful addition to rotary sealing machines. It's renewed and the modular design makes it an ergonomic and economic tool which can be used as single or double rack model on working stations or just mounted on the wall.

Rotary Sealer
This Rotary Sealer is an entry model which is solid, durable and extremely easy to use. Once power is on and the variable temperature adjustment has been done, the Rotary Sealer works when it's needed and stops automatically when the work is done. The basic rotary sealer is microprocessor controlled and the temperature can be adjusted anytime easily. The sensitive temperature ranging between50 °C and 250 °C provides the user with flexibility to seal different kinds of packaging such as paper/film and Tyvek® pouches. Automatic feeding driven by optical sensors and multiline sealing technique ensure optimum seal strength at continuous operations. This sealing system is validated, calibrated and in compliance with international standards.

Screw Cap GL 45 thermocouple holder, DURAN®
The DURAN® Screw Cap GL 45 thermocouple holder consists of a holder fitted into a blue DURAN® polypropylene GL 45 cap that accepts up to three separate thermocouple wires used in autoclaves or sterilizers.Applications"Loaded Chamber heat penetration" tests during Performance Qualification (PQ)Routine sterilization /autoclave cyclesPerformance tests after autoclave maintenance or repairFeaturesUsable with DURAN® original GL 45 laboratory bottles (1000 ml or less).The 240 mm PTFE tube may be cut to lengthSuitable for holding up to three separate thermocouple wires (Conductor sizes 1/0.3 mm, 1/0.5 mm or 7/0.2 mm)Retrace code for product traceability and downloadable certificate

Screw Cap GL 45 with temperature probe holder, DURAN®
The DURAN® temperature probe holder GL 45 consists of a stainless steel holder that is permanently fitted into a blue DURAN® polypropylene GL 45 cap. The holder will accept the 6.0 mm metal temperature measuring probes that are commonly used in laboratory autoclaves and sterilizers.ApplicationsRoutine sterilization /autoclave cycles"Loaded Chamber heat penetration" tests during Performance Qualification (PQ)Performance tests after autoclave maintenance or repairFeaturesUsable with DURAN® original GL 45 laboratory bottles (1000 ml or less).The depth of the probe can be adjusted to suit the bottle sizeAdjustable ferrule suitable for 6.0 mm diameter probesRetrace code for product traceability and downloadable certificateEasy positioning of the sensor in the middle of the bottle

Self-Seal Sterilization Pouches
Self-seal sterilization pouches are pre-folded and assure accurate and fast closing without the requirement of a heat sealing device. They are especially suited for use in small general practices, dental surgeries and by users who want to avoid costs of additional sealing equipment. The self-seal sterilization pouches are constructed from transparent PET/PP multi-layer copolymer film, medical grade paper and adhesive strip which provides excellent resistance to over-exposure of steam and clean opening. Water based, non-toxic process indicators for steam and ethyleneoxide sterilization complying with ISO 11140-1 are applied on the paper surface and help to differentiate between processed and unprocessed packages.Reinforced film to avoid tearing during openingClean and accurate indicator color changeTear, fibre-free opening and aseptic presentationTriple band seal for higher package integrity

Smart vertical autoclaves, TLV series
These autoclaves are microprocessor controlled and monitored with 50 sterilisation programmes and comes with bacteriological filters included by default.Operating temperature range 100 °C to 140 °CWith with vacuum pump and steam generatorMaximum working pressure 2.6 bar (37psi)RS 232 interface, USB and WiFiTimerFully automatic functionsPT 100 temperature sensorCase and lid shrouding, stainless steelSterilisation chamber, lid and sealing system, stainless steelElectrical heating with protected heating elements in the interior of the chamberSafety pressure valveSafety thermostatAutomatic steam controlled by microprocessorPressure gauge4 casters (with brakes in two of them7" capacitive colour touch screenPower Supply: 230V 50/60 HzRemote maintenance and diagnosis via cloudRemote operation monitoring via cloudTLV: BasicTLV-FA: with Air Ballast and Fast CoolingTLV-PD: with Super Drying

Steam Indicator Strips
Class 4 Multi-Variable Steam Indicator StripsClass 4 Multi-Variable Steam indicator strips are designed to be used in steam sterilizers operating at 134 °C -3.5 minutes. The indicator strips can be used in every pack and will provide assurance of steam penetration into the packs.The water based and non-toxic chemical indicator in compliance with ISO 11140-1 will show a clear and accurate color change from blue to black after successful steam sterilization. PMSSteriTest indicator strips are cost effective and can be divided into two separate pieces for more economical use.Dual Strip designDesigned for STEAM sterilization at 134 °C - 3.5 minutes.Water based, non-toxic chemical indicator comply to ISO 11140-1Clear and accurate color change from blue to blackManufactured in absence of lead or other heavy metalsClass 6 Emulating Steam Indicator StripsClass 6 Emulating Steam indicator strips are designed to be used in steam sterilizers operating at 121 °C -15 minutes and 134 °C -3.5 minutes. The cycle verification indicators can be used in every pack and will provide assurance of steam penetration into the packs and presence of all critical parameters of steam sterilization cycle. The water based and non-toxic chemicalindicator in compliance with ISO 11140-1 will show a clear and accurate color change from blue to lilac after successful steam sterilization.Single Strip designDesigned for STEAM sterilization at 134 °C - 3.5 minutes.Designed for STEAM sterilization at 121 °C - 15 minutes.Water based, non-toxic chemical indicator comply to ISO 11140-1Clear and accurate color change from blue to lilacManufactured in absence of lead or other heavy metals

Steam steriliser Laboklav 25
The compact and space saving table top units of the Laboklav 25 series provides you most applications of bigger table top units:sterilisation of liquids in open and lightly closed vessels, also with air re-cooling systemsterilisation of instruments, also with pre-vacuum and drying vacuumwaste sterilisation at 134 °Coptional exhaust air filtration systemvolume of chamber: 25 lmax. permissible pressure: 2.8 barsterilising temperature: 98 to 138 °CA unique design meets innovative technical solutions:optimal use of chamber volume - sufficient for 5 x 1 l standard bottle incl. caplid made of temperature resistant safety glass and lid cover made of safety glassLED front lightning to visualise cycle progressmotor driven and self-checking closing mechanismflexible temperature reference sensor PT100 as serial functionThermolocking device according to IEC 61010-2-40Chamber volume/Chamber size25L useable , Ø 265mm x 465mm Chamber illumination by white LED lightLoad:e.g. 5 x 1L bottle up to 5kg instrumentsDimensions (W x D x H): Space requirement on the table: Weight:440mm x 540mm x 660mm 440mm x 550mm + 110 for door overhang approx. 65kgMax permissible pressure (PS): Max. permissible temperature (TS):2.8 bar 138°CChamber material:Stainless steel, chamber lid made from temperature proof safety glassHousing:Powder coated, red; Front cover from transparent safety glass; Process illumination (LED) in Blue, Red and GreenSteam generation:Integrated steam generator with dry heating elementsHeating power: Electrical connection:2kW 230V ~ 50 Hz, 16ALid closing system:Motorized closing systemSterilisation temperature: Feed water supply:98 to 135 °C, adjustable Integrated feed water tank with manual fillingExhaust steam condensing:Included, discharge into integrated condensate tankThermo locking acc. to IEC 61010-2-43 (TRB 402):Integrated with flexible reference temperature sensor opening, temperature adjustableControl:Micro processor with LCD Display; Code protected access to programming levels; Serial interface RS 485; Internal storage chip to store cycle data of approx. 150 cycles, visualisation and print out at a later stage is possibleProgramms:Up to 10 programms, depending on the integrated option, all programmes can be individualizedNorms and regulations:Manufactured in Germany in full compliance with the relevant norms and regulations. Serial approval by German TUV, CE marking according Pressure Device Directive (Commissioned by factory service at an additional cost)

Steam steriliser LABOKLAV 55 - 195
Steam sterilisers are availible in wide range of chamber sizes between 55 l and 195 l, universal installation options as a free-standing or tabletop unit and numerous configurations provide individual solutions meeting your specific requirements. Typical areas of application for our units include all microbiological laboratories in research institutions, universities, quality controls in the pharmaceutical and food industries as well as waste sterilization, for example in the field of medical diagnosis. Laboklav series autoclaves are characterized by their reliability and quality. We manufacture our products exclusively in Germany to high and continuously monitored quality standards. Our units are TÜV-certified and approved for series production. They comply with the following standards:Pressure Equipment Directive 97/23/EUDIN 58950: Sterilization - Steam sterilizers for pharmaceutical productsDIN 58951: Sterilization - Steam sterilizers for laboratory useNo accessories included, please inform us in your order if a horizontal or vertical device is required.Specifications55 | 100 | 135 | 160 | 195Chamber volume:55 l | 100 l | 135 l | 160 l | 195 lChamber dimensions (Diam. x D):410 x 460 mm | 410 x 760 mm | 500 x 660 mm | 500 x 760 mm | 500 x 990 mmOuter dimensions of free-standing unit (W x H x D):740 x 765 x 600 mm | 740 x 1065 x 600 mm | 840 x 965 x 700 mm | 840 x 1065 x 700 mm | 840 x 1215 x 700 mmOuter dimensions of tabletop unit (W x H x D):740 x 600 x 765 mm | 740 x 600 x 1065 mm | 840 x 700 x 965 mm | 840 x 700 x 1065 mm | 840 x 700 x 1215 mmWeight:115 kg | 185 kg | 195 kg | 210 kg | 245 kgMax. allowable pressure (PS):2,8 barMax. allowable temperature (TS):143 °CHeating power of steam generator:3-6 kW, selectable | 6 kW, selectable | 6-10 kW, selectable | 6-10 kW, selectable | 10 kWElectrical connection:3N 400 V ~, 50 Hz, 16 ASterilization temperature:98 ... 135 °C, adjustable

Steam sterilizers (autoclaves), HG series
Certified according to the Pressure Equipment Directive 2014/68/EUAvailable in 2 sizes with 50 and 80 liters of effective usable volumeInnovative locking system with motorized lid including pressure and temperature monitoringSteam generation in the chamberHigh energy efficiency and long service lifeRapid cooling for short cooling timesAlso available with flexible temperature sensor for the sterilization of liquidsTimer function and 4 program groups with 3 sub-groups each, including night and dissolution program, adjustments for customized programs are always possibleNo water/waste-water installation requiredCastors for mobile useEasy to clean plastic surface with rounded edges in contact areas (no burns or injuries).Electrical, mechanical and constructional factors guarantee the highest level of quality and user protectionThe accessories make it possible to configurate the autoclave according to your wishesExhaust air filters for laboratories of safety level S2 and higher are also available

Steam sterilizers (autoclaves), HV series
Tireless, durable and ingeniously simpleCertified according to the Pressure Equipment Directive 2014/68/EUAvailable in 4 sizes with 25, 50, 85 and 110 liters of effective usable volumeSimple, reliable and with a long service life, your perfect choice for standard tasksOptionally available with flexible temperature sensor for the sterilization of liquidsFor all devices up to 110 liters only a single-phase power supply (220/240 V; 50/60 Hz) is requiredTimer function and 3 program groups with a max. of 6 programs including dissolution program, adaptions for customized programs are always possibleNo installation to a feed water supply requiredCastors for mobile useEasy to clean plastic surface with rounded edges in contact areas (no burns or injuries)Electrical, mechanical and constructional factors guarantee the highest level of quality and user protectionThe accessories make it possible to configurate the autoclave according to your wishesExhaust air filters for laboratories of safety level S2 and higher are optionally available

Steam sterilizers Laboklav 80
Laboklav 80 series provides an extensive and diversified range of equipment variants - customized for you laboratory application. The focus is on safe and reproducible processes, safety for the user and the environment as well as a comfortable operation of the autoclave. All steam steriliser are:suitable for the liquid sterilisation in open and lightly closed vessels, solid sterilisation and waste sterilisation at 134°Cupgradable for high demanding laboratory applicationsvolume of chamber: 80lmax. permissible pressure: 2.8barsterilising temperature: 98°C to 138°Cmotor driven and self-checking closing mechanismflexible temperature reference sensor PT100 as serial functionThermolocking device according to IEC 61010-2-40A unique installation concept for varied installation possibilities:The autoclave can be installed as vertical or as horizontal unit - without additional costs!The lid can optionally be opened to the right, to the left or backwards.All units can be delivered in three colours: red, green or blue.Numerous equipment variants:vacuum system for difficult to de-aerate solids incl. fractionated pre-vacuum and drying vacuumfast re-cooling system for liquid sterilisation using a double jacket, without rejection of demineralised waterupgrade of the re-cooling system with counter pressure and fan possible - for further reduction of batch timesoptional exhaust air filtration systemAccessories are available on request!

Sterilisation Pouches Qualitix®
Suitable for many laboratory instruments. The disposable bags are used for simple and effective wrapping of sterilization goods that are visible through the transparent PET / CPP film. With the self-sealing strip they can be closed safely and quickly.Intended for steam and EO gas sterilizationWith two colour indicatorsRobust, durable materialWide, self-sealing stripThumb notch for easy openingISO 17665-06 and ISO 11135 conform

Sterilisation rolls, flat
Heat-sealable sterilisation reels as a packaging solution for sterilisation applications, ensure reliable protection of the medical device against contamination with bacteria from the time of sterilisation until use of the sterile medical device. The sterilisation reels are constructed from transparent PET/PP multi-layer copolymer film and medical grade paper. Water based, non-toxic process indicators for steam and ethylene oxide sterilisation (complying with ISO 11140-1) are applied on the paper surface. This helps differentiating between processed and unprocessed packages. The sterilisation reels are effective barriers against germs and according the requirements of ISO 11607, EN 868-5 and ISO 11140-1 standards.Reinforced film to avoid tearing during openingClean and accurate indicator colour changeTear, fibre-free opening and aseptic presentationTriple band seal for higher package integrityHeat sealable sterilisation rollsHeat-sealable sterilisation reels as a packaging solution for sterilisation applications, ensure reliable protection of the medical device against contamination with bacteria from the time of sterilisation until use of the sterile medical device. The sterilisation reels are constructed from transparent PET/PP multi-layer copolymer film and medical grade paper. Water based, non-toxic process indicators for steam and ethylene oxide sterilisation (complying with ISO 11140-1) are applied on the paper surface. This helps differentiating between processed and unprocessed packages. The sterilisation reels are effective barriers against germs and according the requirements of ISO 11607, EN 868-5 and ISO 11140-1 standards.Reinforced film to avoid tearing during openingClean and accurate indicator colour changeTear, fibre-free opening and aseptic presentationTriple band seal for higher package integrityHeat sealable sterilisation rolls

Sterilisation rolls, with gusset
Heat-sealable sterilisation reels as a packaging solution for sterilisation applications, ensure reliable protection of the medical device against contamination with bacteria from the time of sterilisation until use of the sterile medical device. The sterilisation reels are constructed from transparent PET/PP multi-layer copolymer film and medical grade paper. Water based, non-toxic process indicators for steam and ethylene oxide sterilisation (complying with ISO 11140-1) are applied on the paper surface. This helps differentiating between processed and unprocessed packages. The sterilisation reels are effective barriers against germs and according the requirements of ISO 11607, EN 868-5 and ISO 11140-1 standards.Reinforced film to avoid tearing during openingClean and accurate indicator colour changeTear, fibre-free opening and aseptic presentationTriple band seal for higher package integrityHeat sealable sterilisation rollsHeat-sealable sterilisation reels as a packaging solution for sterilisation applications, ensure reliable protection of the medical device against contamination with bacteria from the time of sterilisation until use of the sterile medical device. The sterilisation reels are constructed from transparent PET/PP multi-layer copolymer film and medical grade paper. Water based, non-toxic process indicators for steam and ethylene oxide sterilisation (complying with ISO 11140-1) are applied on the paper surface. This helps differentiating between processed and unprocessed packages. The sterilisation reels are effective barriers against germs and according the requirements of ISO 11607, EN 868-5 and ISO 11140-1 standards.Reinforced film to avoid tearing during openingClean and accurate indicator colour changeTear, fibre-free opening and aseptic presentationTriple band seal for higher package integrityHeat sealable sterilisation rolls

Tabletop autoclaves CertoClav Classic
Its versatility and compact construction make autoclaves especially interesting for small labs or they can be used as an optimal addition to a large autoclave.All models: Low-maintenance. No water connection required. Compliant with 2014/35/EU Low Voltage Directive, 2014/30/EU EMV Directive, 2011/65/EU Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment.Vertical models: Class N steam sterilisers. Venting procedure: free steam flow process or fractional flow procedure. A heater is integrated in the bottom of the chamber, but it is not exposed. Therefore, it cannot calcify. The autoclaves are easy to transport and location independent. All you need is a power supply and a mixture of tap water and demineralised water. Safeguarded by a multiple safety system. In aluminum models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and the overpressure safety cavity. In stainless steel models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and a two-bimetal safeguard to prevent overheating of the device.CertoClav Classic is suitable for sterilisation of unwrapped solids without hollow bodies, liquids, bottles, instruments, synthetic materials, culture media preparation and waste sterilisation.A precision thermometer, a control valve and a precision manometer with drag indicator ensure exact processes and perfect results for all applications. The model is available in two versions, each with two temperature levels. The respective temperature level is set via the control valve in the lid. The valves cannot be interchanged as the thermostat of the appliance is matched and adjusted to the respective valve. The water supply is a mixture of tap water and demineralised water.Our autoclaves are protected by a multiple safety system. It consists of a pressure relief valve, a pressure valve, a safety lid lock to prevent opening under pressure and a BI metal fuse to prevent the appliance from overheating.Touchscreen controlRobust construction, low-maintenanceTransportable and location-independentThermostat controlIntegrated timerVenting in flow processHeating integrated in the baseScope of supply: Autoclave, instrument tray, power cable

Tabletop autoclaves CertoClav EL
Its versatility and compact construction make autoclaves especially interesting for small labs or they can be used as an optimal addition to a large autoclave.All models: Low-maintenance. No water connection required. Compliant with 2014/35/EU Low Voltage Directive, 2014/30/EU EMV Directive, 2011/65/EU Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment.Vertical models: Class N steam sterilisers. Venting procedure: free steam flow process or fractional flow procedure. A heater is integrated in the bottom of the chamber, but it is not exposed. Therefore, it cannot calcify. The autoclaves are easy to transport and location independent. All you need is a power supply and a mixture of tap water and demineralised water. Safeguarded by a multiple safety system. In aluminum models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and the overpressure safety cavity. In stainless steel models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and a two-bimetal safeguard to prevent overheating of the device.The vertical laboratory autoclave is suitable for sterilisation of unpackaged solids without hollow bodies, liquids, bottles, instruments, synthetic materials, food preservation, culture media preparation and waste. A precision thermometer, a control valve, and a precision manometer with drag indicator provide precise processes and accurate results for all applications. The autoclave is available in two versions, each with two temperature levels. These temperature settings are controlled via the control valve on the lid. These valves are not interchangeable, because the thermostat of the device is harmonized with and calibrated to the respective valve.Robust constructionThermostat controlledHigh heating powerVenting by flow procedureHeating integrated in the baseScope of supply: Autoclave, instrument tray, power cable

Tabletop autoclaves CertoClav MultiControl
Its versatility and compact construction make autoclaves especially interesting for small labs or they can be used as an optimal addition to a large autoclave.All models: Low-maintenance. No water connection required. Compliant with 2014/35/EU Low Voltage Directive, 2014/30/EU EMV Directive, 2011/65/EU Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment.Vertical models: Class N steam sterilisers. Venting procedure: free steam flow process or fractional flow procedure. A heater is integrated in the bottom of the chamber, but it is not exposed. Therefore, it cannot calcify. The autoclaves are easy to transport and location independent. All you need is a power supply and a mixture of tap water and demineralised water. Safeguarded by a multiple safety system. In aluminum models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and the overpressure safety cavity. In stainless steel models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and a two-bimetal safeguard to prevent overheating of the device.The PT100 sensor-controlled, vertical laboratory autoclave is suitable for extended/ long- term cycles, material tests, HAST test, Pressure Cooker Test, ICP-TM 650, culture media preparation, sterilisation of waste, hazardous biological substances (S2), unpackaged solids without hollow bodies, liquids, bottles, instruments, synthetic materials and rubber.Without connecting a PC, the control unit can only be used to set programs that include just one time and one temperature step. For programs that include several time and temperature steps, the PC software professional version is required.Microprocessor-controlledVenting by fractional flow procedureElectronic process controlProgrammable from 1 minute to 30 days and from room temperature to 140 °CControl unit with LCD displayUSB portPrinter port (RS232) for printing sterilisation protocolsHeating integrated in the baseScope of supply: Autoclave, MC2 control unit, instrument tray, power cable, PC software basic version

Tabletop autoclaves CertoClav STE-45-T
The preheatable chamber, air cooling system and vacuum pump enable a fast sterilisation cycle including drying. Due to the intelligent combination of vacuum, pressure and steam, the autoclaves are suitable for solid bodies of all materials as well as hollow bodies. The additional media sensor guarantees a complete sterilisation of liquids such as culture media. A drip tray is necessary for autoclaving liquids. The autoclaves can be connected to the free CertoCloud.7-inch touchscreen with video assistantUp to 50 user-definable programs can be freely createdFlexible sensor for measuring the temperature of mediaWater quality sensorAutomatic documentationRS232, RS485, USB, ethernet, LAN, WiFiIntegrated documentation (GMP/GLP conform)Scope of supply: Autoclave, CertoAssist touchscreen, instrument tray, power cable, CertoCloud basic licence

Tabletop autoclaves CertoClav VacPro
The preheatable chamber, air cooling system and vacuum pump enable a fast sterilisation cycle including drying. Due to the intelligent combination of vacuum, pressure and steam, the autoclaves are suitable for solid bodies of all materials as well as hollow bodies. The additional media sensor guarantees a complete sterilisation of liquids such as culture media. A drip tray is necessary for autoclaving liquids. The autoclaves can be connected to the free CertoCloud.7-inch touchscreen with video assistantUp to 50 user-definable programs can be freely createdFlexible sensor for measuring the temperature of mediaWater quality sensorAutomatic documentationRS232, RS485, USB, ethernet, LAN, WiFiIntegrated documentation (GMP/GLP conform)Scope of supply: Autoclave, CertoTouch screen, instrument tray, power cable, CertoCloud basic license

Tabletop autoclaves LabStar 40
Small laboratory table-top autoclave with round chamber for sterilization tasks of various kinds. A hinged lid with electromotive locking mechanism in combination with the robust lip seal ensures easy and safe closing of the sterilization chamber. A temperature lock in the liquid program prevents opening at temperatures higher than 80 °C and therefore unwanted boiling delay. For an exact control the autoclave has an electronic absolute pressure sensor and a flexible temperature sensor PT100 Kl. A.Loading capacity: 15 medium-flasks or 11 Erlenmeyer flasks (500 ml)Safe and simple locking deviceCompletely made of stainless steelFits on any laboratory benchEquipment versionsBasic Lab: With heating elements. For the sterilization of simple materials or liquids without removal dry.Dry Lab: With heating elements, membrane-vacuum pump. For the sterilization of non-infectious waste bags and materials which require intensive subsequent drying.Quick Lab Basic: With heating elements, water-cooling system, internal heat exchanger. For the sterilization of large quantities of liquids.Quick Lab: With heating elements, water-cooling system, internal heat exchanger, membrane-vacuum pump. For the sterilization of non-infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying.Safe Lab: With heating elements, membrane-vacuum pump, exhaust air filtration EAF. For operation in the level S2 lab. Recommended for the sterilization of infectious waste bags and materials which require intensive subsequent drying.Complete Lab: With heating elements, membrane-vacuum pump, exhaust air filtration EAF, water-cooling system, internal heat exchanger. Fully equipped laboratory autoclave for operation in the level S2 lab. Recommended for the sterilization of infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying.SpecificationsChamber volume:40Permissible operating pressure:3.8 bar absolutePermissible operating temperature:140 °CHeat output:2.5 kWChamber dimensions (W x D x H):295 x 460 x 295 mmOuter dimensions (W x D x H):532 x 698 x 605 mmWeight basic unit:65 kgPower supply:240 V, 50 Hz, 16 A