Its versatility and compact construction make autoclaves especially interesting for small labs or they can be used as an optimal addition to a large autoclave.

All models: Low-maintenance. No water connection required. Compliant with 2014/35/EU Low Voltage Directive, 2014/30/EU EMV Directive, 2011/65/EU Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment.

Vertical models: Class N steam sterilisers. Venting procedure: free steam flow process or fractional flow procedure. A heater is integrated in the bottom of the chamber, but it is not exposed. Therefore, it cannot calcify. The autoclaves are easy to transport and location independent. All you need is a power supply and a mixture of tap water and demineralised water. Safeguarded by a multiple safety system. In aluminum models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and the overpressure safety cavity. In stainless steel models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and a two-bimetal safeguard to prevent overheating of the device.

The PT100 sensor-controlled, vertical laboratory autoclave is suitable for extended/ long- term cycles, material tests, HAST test, Pressure Cooker Test, ICP-TM 650, culture media preparation, sterilisation of waste, hazardous biological substances (S2), unpackaged solids without hollow bodies, liquids, bottles, instruments, synthetic materials and rubber.
Without connecting a PC, the control unit can only be used to set programs that include just one time and one temperature step. For programs that include several time and temperature steps, the PC software professional version is required.

  • Microprocessor-controlled
  • Venting by fractional flow procedure
  • Electronic process control
  • Programmable from 1 minute to 30 days and from room temperature to 140 °C
  • Control unit with LCD display
  • USB port
  • Printer port (RS232) for printing sterilisation protocols
  • Heating integrated in the base


Scope of supply: Autoclave, MC2 control unit, instrument tray, power cable, PC software basic version

Dimensions internal (Ø x H): 240 x 260 mm
Ext. depth: 275 mm
Ext. height: 480 mm
Ext. width: 395 mm
External dimensions (WxDxH): 395 x 275 x 480 mm
Heating capacity: 1900 W
Height int.: 260 mm
Int. Ø: 240 mm
Manufacturer Article Number: 8502312A
Material interior: Aluminium
Max. pressure: 2.7 bar
Max. temperature: 140 °C
Max. voltage: 230 V
Min. temperature: 20 °C
Nominal capacity: 12 l
Power supply: 230 V, 50/60 Hz
Power supply frequency: 50/60 Hz
Temperature: 20 ... 140 °C
Type: MultiControl
Type of auxiliary energy: Mains connection
Weight: 6.6 kg

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessories

Accessories for autoclaves, CertoClav
Accessories for autoclaves, CertoClav

Regular price: €0.00
Skip product gallery

Other customers also bought

Tabletop autoclaves CertoClav EL
Tabletop autoclaves CertoClav EL

Its versatility and compact construction make autoclaves especially interesting for small labs or they can be used as an optimal addition to a large autoclave.All models: Low-maintenance. No water connection required. Compliant with 2014/35/EU Low Voltage Directive, 2014/30/EU EMV Directive, 2011/65/EU Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment.Vertical models: Class N steam sterilisers. Venting procedure: free steam flow process or fractional flow procedure. A heater is integrated in the bottom of the chamber, but it is not exposed. Therefore, it cannot calcify. The autoclaves are easy to transport and location independent. All you need is a power supply and a mixture of tap water and demineralised water. Safeguarded by a multiple safety system. In aluminum models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and the overpressure safety cavity. In stainless steel models, it consists of an overpressure valve, a pressure valve, a safety lock inside the lid to prevent opening under pressure and a two-bimetal safeguard to prevent overheating of the device.The vertical laboratory autoclave is suitable for sterilisation of unpackaged solids without hollow bodies, liquids, bottles, instruments, synthetic materials, food preservation, culture media preparation and waste. A precision thermometer, a control valve, and a precision manometer with drag indicator provide precise processes and accurate results for all applications. The autoclave is available in two versions, each with two temperature levels. These temperature settings are controlled via the control valve on the lid. These valves are not interchangeable, because the thermostat of the device is harmonized with and calibrated to the respective valve.Robust constructionThermostat controlledHigh heating powerVenting by flow procedureHeating integrated in the baseScope of supply: Autoclave, instrument tray, power cable

Regular price: €0.00