Thermocycler MultiGene™ OptiMax
This simple to program PCR thermocycler unit is compact in design, programming is intuitive with the large display and multiple pre-programmed templates supplied with the unit. The OptiMax comes with standard built in 2-step, temperature optimization, touchdown and time increment protocols that are easy to adjust to meet cycling needs. Select lid temperature or turn it off.Flexible Programming with FlexTemp™ technologyFast ramp rates 5 °C heating / 3.5 °C coolingNo condensation after overnight cooling at 4 °CIndividual temperature setting for each blockPassword protected programsSimple user interfaceWith USB and RS232 interfaceSpecifications:Sample capacity:1 x 96 well plate, 12 x strip tubes (8 x 0.2 ml), 96 x 0.2 ml tubesProgrammable temperature range:4 °C ... 99.9 °CTemperature control:Calculated or blockTemperature accuracy/uniformity:±0.5 °C/±0.5 °CHeating/cooling method:PeltierMax. heating/cooling rate:±5 °C/±3.5 °C per secondTemperature range of 6-segment blocks:30 °C ... 99 °C (can be set independently)Maximum temperature difference between 6-segment blocks: ±24 °CProgrammable lid temperature:60 °C ... 65 °C, 100 °C ... 115 °CProgram memory: User program folders:200 complete programs 50 setsDimensions (W x D x H):240 x 420 x 250 mmWeight:9 kgSupply requirements:230 V, 50/60 Hz*

Thermocyclers 3PRIMEBASE / 3PRIMEX / 3PRIMEG
Mid-size thermocyclers - find space on any laboratory benchApproved cycler with new designWith and without gradient functionGradient upgrade from 3PRIMEX to 3PRIMEG3.5" colour touch screen with graphical displayHeight-adjustable and heatable lid, temperature from 100°C to 115°C, with ON/OFF switch and automatic switch off against overheatingPassword protectedAuto-RestartUSB port4 years warranty for the Prime ThermocyclerSpecificationsBlock temperature:+4°C to +100°CTemperature gradient (only 3PRIMEG or 3PRIMEX with upgrade):+30°C to +80°CMax. Gradient:+14°CBlock uniformity at 55°C:±0.3°CMax. Heating rate:3.0°C/sDimensions (W x D x H):210 x 350 x 180

Tissue Grinders System
For safety grinding of any cells by minimal temperature rising. Closed System (CS) for minimizing the risk of personal contact with aerosols and sample overflow while grinding. Optimal contact of grinder and conical sample tube (15 or 50ml) to grind each cell in the best way.Each unit is gamma sterilized and comes with a fully assembled pestle , conical sample tube (PP), solid top cap (HDPE) and label.Type CS1: Tip from glass-filled PP (30%/70%) for standard grindingType CS2: Vitrified tip (cast silica) for harder grinding

Tissue Vial CryoELITE®, sterile
The CryoELITE® Tissue Vials are specifically designed for tissue collection, transport and storage. Different from cells and biofluids, tissue specimens have particular requirements for cryogenic storage. Offering researchers a uniform vial able to maintain sample integrity while maximizing storage capacity and organization, the CryoELITE Tissue Vials feature a wide-mouth opening, 5mL capacity and high integrity closure. The CryoELITE Tissue Vial offers researchers who work with tissue samples ease of use, convenience and security.The CryoELITE® Tissue Vials are manufactured from low binding, cryogenicgrade virgin polypropylene that meets the USP Class VI classification. Lot tested and certified to be free of pyrogens, RNase / DNase and endotoxins, the vials have a sample capacity of 5mL and a storage temperature range of -156°C to 121°C. The externally threaded cap provides a seal that exceeds DOT and IATA classifications for diagnostic specimens and their transport and is capable of maintaining a secure closure during freeze/thaw procedures. The vials have a flat bottom and a stippled external surface to promote easier handling.Lot certified RNase/DNase and Endotoxin Free providing assurance of product integrityCap seal exceeds DOT and IATA regulations ensuring ultimate protection of samples during transportation and demanding freeze-thaw handlingWide mouth for insertion and removal of tissue with forceps5 ml volume for use with tissue sectionsDirectional indicators to allow orientation of tissue within the vial

Toothpick in dispenser
Toothpick in dispenser, loose with 2 tips, pack of 1000 per dispenser.

TPX Single sample chamber Shandon™
Reusable sample chamber used with a cap, slide holder, and disposable filter card to prepare thin-layer preparations.Use with disposable white filter card (high absorbency) for routine sample volumes from 0.1 to 0.5 mlUse with disposable brown filter card (slow absorption) for hypocellular sample volumes from 0.1 to 0.4 mlAutoclavablePlease order cap, slide clip, and disposable filter card separately.

Transfer membrane, nitrocellulose
Pure Nitrocellulose transfer membrane for all protein or immunoblotting applications. The high sensitivity and low background ensures excellent results in all transfers. Compatible with all detection systems. BSA binding capacity up to 100µg/cm2.Signal word:H phrases:P phrases:

Transfer membrane, PVDF
Hydrophobic Polyvinylidene Fluoride (PVDF) transfer membrane with high binding capacity and low background. Ideal for use in protein binding applications such as Western blots, solid phase assays and immunoblotting procedures. BSA binding capacity up to 125 µg/cm2

Transfer membrane, supported nitrocellulose
Supported Nitrocellulose transfer membranes combine the binding characteristics of nitrocellulose membranes with the strength of nylon membranes. These membranes are used for DNA/RNA transfers requiring low background or for multiple hybridizations. For use with chemiluminescence and radiographic detection systems. BSA binding capacity up to 100 µg/cm2.Signal word:H phrases:P phrases:
Transfer membranes Amersham Hybond LFP, PVDF
Low fluorescent, hydrophobic blotting membrane for protein transfer. Optimized for fluorescence detection in Western blotting applications.Protein binding capacity over 200 µg/cm2Higher sensitivity due to low background fluorescenceCompatible with many blocking agents, transfer buffers and total protein blot stainsAvailable in the standard precut sizes for laboratory applications
Transfer membranes Amersham Hybond P, PVDF
Hydrophobic membrane with high physical strength, suitable for stripping and reprobing. For use with standard colourimetric and chemiluminescent detection methods for proteins of < Mr 20 000.Protein binding capacity over 200 µg/cm2High protein retention even after harsh washing stepsAvailable in popular sizes for laboratory application

Transfer membranes Amersham Hybond SEQ, PVDF
Hydrophobic Western blotting membrane specifically designed for protein sequencing applications and solid-phase amino acid analysis.High protein binding capacityChemical resistance needed for N-terminal sequencingHigh protein retention even after harsh washing stepsMinimizes "blow-through" and increases protein bindingAvailable in popular sizes for laboratory application
Transfer membranes Amersham Protran
Pure nitrocellulose with extreme mechanical stability - gives excellent useability. For protein transfer and DNA/RNA transfer techniques. Optimum signal/background ratio.

Transfer membranes Optitran®
Webbing reinforced nitrocellulose.High mechanical stability for multiple hybridisations.
Transfer System Nytran SuPerCharge Turboblotter™, refill pack
The TurboBlotter is very easy to set up, and works without power or vacuum source. Offers high resolution transfer of DNA and RNA with unique downward capillary transfer in one hour. Reusable blotting device requires less buffer and blotting paper. Scope of supply: 5 transfers

Trimming Knives
For cutting tissue samples without causing deformation for large tissue blocks.


Tube tests for anaerobes Lovibond® Dipslides
The Lovibond® Dipslides are designed to test liquids as well as surfaces. They are ideal for use in many applications including evaporative cooling towers, closed water circuits, cutting fluids, food testing, and many more.Semisolid medium measures anaerobic bacteria and indicates microbial induced corrosion.

Tubes Mini Flip-Top with Buffered Peptone Water Broth
Hinged lid can be opened with one hand and stays open for easy sample additionsDecontaminated through gamma irradiation and ready for use with no additional blending requiredFlat bottom tube stands on its own, no holder requiredLeak resistant vial helps prevent leakage during shipping2 year shelf life from date of manufacture provides long-term readiness

Tubes, glass, DURAN®, culture, screw cap
DIN thread. Complete with red PBT screw cap with PTFE-faced sealing wad. Thus, it is suitable for the cultivation of microorganisms. Glass Type I / neutral glass as per USP, EP and JP. Autoclavable.

TubeSpin® Bioreactor 50, TPP® for Bioreactors RTS-1 / RTS-1C
With membrane filter.

U96 Immuno™ Plates, PS, with Immulon™ 1B surface
Clear plates with excellent optical quality and round well bottom.Immulon™ 1B serve to absorb hydrophobic molecules.
U96 Immuno™ Plates, PS, with Immulon™ 2 HB surface
Clear plates with excellent optical quality and round well bottom.
U96 MicroWell™ Plates, PS, non-treated
Clear plates with excellent optical quality and round well bottom.

U96 MicroWell™ Plates, PS, with MaxiSorp™ surface
Clear plates with excellent optical quality and round well bottom.MaxiSorp™ suitable for solid phase immuno assays. MaxiSorp™ is hydrophilic and ideal for antibody sandwich assays.
U96 MicroWell™ Plates, PS, with Nunclon™D surface
Clear plates with excellent optical quality and round well bottom.Nunclon™Δ surface optimized for cell based assays and sterile non-treated versions for bacteriological applications. Certified.

U96 MicroWell™ Plates, PS, with PolySorp™ surface
Clear plates with excellent optical quality and round well bottom.PolySorp™ suitable for solid phase immuno assays. PolySorp™ serve to absorb hydrophobic molecules.

U96/V96 MicroWell™ Plates, PP
V-shape provides optimal recovery of reagentsShared wall technology increases well volume and wider cells improve mixingIdeal as collection plate for Nunc Filter PlatesLow binding for homogeneous assays and storage

Ultra-Micro dialysers QuikPrep® Ultra-Micro DispoDialyzer
Disposable dialyser for processing extremely small samples from 1 to 5 µl. Dialysis is performed in a microcentrifuge tube. Each Ultra-micro dialyser includes two 1.5 ml microcentrifuge collection tubes with lids. After dialysis, the sample can either be removed with a pipette or the dialyser can be inserted into a new microcentrifuge collection tube and briefly centrifuged (500 to 2000 rpm for 1 to 2 seconds). Ideal for buffer exchange, detergent removal, sample concentration for HPLC/HPCE, and purification of proteins, DNA and RNA.Easy handlingLow protein bindingHigh sample recoveryRapid dialysis/purification