
Florisil® adsorbent for low pressure column chromatography
hard granular magnesia silica gel: MgO 15.5±0.5%, SiO2 84.0 ±0.5%,Na2SO4œ1.0%; 60/100 meshtypical applications: sample preparation (SPE); clean-up of pesticide residues, separation of chlorinated pesticides, extraction of steroids, sex hormones, antibiotics, lipids etc.


Funnels for Safety Waste Caps V3.0, HDPE, electrostatic conductive
Lid with sealing ringWith grounding cable

Gas and vapor sampler kit
The gas and vapor sampler enables spot collection of environmental gas samples or low pressure gas streams in 200 cm3 impervious resealable bags. Ideal for field analysis.Scope of supply: Canister, bulb, 10 bags, marker pen, instructions

Gas chromatography flow meter GF500
Convenient digital flow meter for the simple, accurate and repeatable measurement of flow in gas chromatographs. User friendly, handy design. Can be used with the carrier gases Air, Hydrogen, Nitrogen, Helium, Carbon dioxide, Argon and Argon/Methane. OLED display shows flow rate and further information. With pressure and temperature compensation. Suitable for columns with diameters of 100, 180, 200, 250, 320, 450, 530 and 750 µm.Measurement of flow rate, linear velocity and split ratioHigh resolution25 point calibration, traceable to National StandardsRechargeable batteryAuto power offScope of supply: Flow meter with case, tubings, tubing adapter fittings, tubing clips, tie-wraps, universal charger with USB connector, operation manual, calibration certificate.Please order adapters for direct connection to the detector separately.SpecificationsRange:0…500 ml/min. (0…300 ml CO2)Accuracy:0.4 ml/min. / ±2.5 %Resolution:0.1 ml/min.Operating temperature:15…35 °C, calibrated at 21±2 °CInlet pressure:max. 175 kPaDimensions:68 x 30 x 130 mmWeight:150 g

Gas filters
Gas filters are an essential part of GC analysis as contaminants in gases can significantly impact the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column and excessive bleed. The gas filter kit consists of a gas filter and a connection unit.Fast stabilization timesThe gas filter system consists of two key parts: the filters and the connecting unitThe connecting unit has inlet and outlet connectors for the gas linesThe connecting unit can be bench or wall-mountedCan be used in combination with other filtersIndicator color change tells you when to change your filter

Gas filters big trap
Gas filters are an essential part of your GC analysis as contaminants in gases can significantly impact the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column and excessive bleed.Heavy-walled aluminium tubeHigh capacity filtersSintered stainless steel frits prevent particulate contaminationSpecificationsVolume:750 cm3Pessure rating:up to 17.2 bar

Gas syringes, FORTUNA®, soda lime glass
Clear glass, with calibrated cylinder.With chemically-resistant, diffused amber stain graduations.

Gas syringes, FORTUNA®, soda lime glass, with capillary stopcock
Clear glass, with calibrated cylinder.With chemically-resistant, diffused amber stain graduations.

GC Capillary columns HYDRODEX β-6TBDM
HYDRODEX cyclodextrin phases for enantiomer separationHeptakis-(2,3-di-O-methyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for γ-lactones, cyclopentanones, terpenes, esters, tartrates.Max. temperature for isothermal operation: 230 °CMax. temperature for short isotherms in a temperature programme: 250 °C

GC Capillary columns HYDRODEX β-TBDAC
HYDRODEX cyclodextrin phases for enantiomer separationHeptakis-(2,3-di-O-acetyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for alcohols, esters, ketones, aldehydes, δ-lactones.Max. temperature for isothermal operation: 220 °CMax. temperature for short isotherms in a temperature programme: 240 °C

GC Capillary columns LIPODEX® E
LIPODEX® cyclodextrin phase for enantiomer separationBase material: cyclic oligosaccharide consisting of eight glucose units bonded through α-1,4-linkages (y-cylodextrin) regioselective alkylation and acylation of the hydroxyl groups leads to a lipophilic phase, which is well suited for GC enantiomer analyses; important advantage: many compounds can be analysed without derivatisation (however, for certain substances enantioselectivity can be favourably influenced by formation of derivatives).Octakis-(2,6-di-O-pentyl-3-O-butyryl)-γ-cyclodextrin. Recommended for α-amino acids, α- and β-hydroxycarboxylic acid esters, alcohols (TFA), diols (TFA), ketones, pheromones (cyclic acetals), amines, alkyl halides, lactones.Max. temperature for isothermal operation: 200 °CMax. temperature for short isotherms in a temperature programme: 220 °C

GC Ferrules, Graphit/ Vespel®
High quality ferrules made of 15 % Graphite / 85 % Vespel®. 1/16" GC ferrule long.

GC Ferrules, Graphit/ Vespel®, Agilent style
High quality ferrules made of 15 % Graphite / 85 % Vespel®. 1/16" GC ferrule.
GC Ferrules, Graphit/ Vespel®, two-hole
High quality ferrules made of 15% Graphite / 85% Vespel®. 1/16" GC ferrule long.

GC-Syringes PAL Headspace®
HD syringe: High Dynamic plunger has been optimised for higher throughput in the headspace technique.Novel metal spring allows working with enhanced tightness over a large temperature range. Which results in increased accuracy and reproducibility of your headspace GC analysis.HDHT syringe: Unique cement-free snap-on connection. The syringe is chemically inert and temperature stable up to 200 °C which broadens the range of possible applications.

Glass Wool, quartz wool, glass fiber wadding
Glass wool, quartz wool and glass fiber wadding are, e.g., used for GC liners, packed GC columns etc.
GLP plates silica gel 60
Glass plates are additionally marked with article, batch and individual plate number. Ideal for GLP applications.Easy traceability, archiving and documentationWith or without fluorescent indicator F254


Guard columns for EC columns NUCLEODUR® C18 Gravity, 3µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsGuard columns for EC columns require guard column adapter EC (Cat. No. 7.081 898)
Guard columns for EC columns NUCLEODUR® C18 Isis, 3 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsGuard columns for EC columns require the guard column adapter EC.

Guard columns for EC columns NUCLEODUR® C18Gravity, 5µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsGuard columns for EC columns require guard column adapter EC (Cat. No. 7.081 898)
Guard columns for NUCLEOGEL® SUGAR 810 Ca columns
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyThis guard columns require the CC column holder 30 mm.