
Capillary columns GC BP5
5% Phenyl / 95% Dimethyl Polysiloxane. Low bleed. General purpose GC column for all routine analyses such as aromatics, pesticides, herbicides, hydrocarbons. Suitable replacement for: DB-5, Rtx-5, HP-5, Ultra-2, PTE-5, SPB-5, MDN-5, CP-Sil 8CB, VB-5, ZB-5, VF-5ms.

Capillary columns GC BP5MS
5% Phenyl Polysilphenylene-siloxane. For 5% GC-MS analysis and general purpose MS analysis. Suitable replacement for: DB-5ms, ZB-5ms, Rxi-5Sil MS, VF-5ms, CP-Sil 8 CB.

Capillary columns GC BPX-BIOD6584
Optimised for specified ASTM D6584 biodiesel methods.

Capillary columns GC BPX-Dioxin
For Dioxins and related compounds (POPs, PCBs, PCDFs, PCDDs).Very low bleedNon-polarExtremely inertIdeal for GC-MS

Capillary columns GC BPX35
35 % Phenyl Polysilphenylene-siloxane. Suitable Replacement for: DB-35, DB-35ms, Rtx-35, HP-35, HP-35MS, SPB-35, MDN-35.Very low bleedInertMid polarity columnEquivalent to USP phase G42High temperatureAble to be solvent rinsed

Capillary columns GC BPX5
5% Phenyl Polysilphenylene-siloxane. General purpose GC column for routine gas chromatographic analysis. Suitable replacement for: DB-5, DB-5ms, DB-5.625, XTI-5, Rtx-5ms, Ultra-2, HP-5, HP-5MS, HP5-TA, SPB-5, MDN-5S, CP-Sil8CB, Rxt-Sil 5MS, AT-5ms, VB-5, ZB-5, VF-5ms.Very low bleedNon-polarExtremely inert

Capillary columns GC BPX608
35% Phenyl Polysilphenylene-siloxane. For environmental analyses, EPA 608, pesticides and herbicides. Suitable replacement for: DB-608, Rtx-35, SPB-608, HP-35, ZB-35.

Capillary columns GC BPX70
70% Cyanopropyl Polysilphenylene-siloxane. Able to be solvent rinsed. Industry standard column for fatty acid methyl esters, carbonhydrates, pharmaceuticals, GC/MS applications. Suitable alternative to: DB-23, Rtx-2330, SP-2330, CP-Sil 88, SP2380, HP-23.

Capillary columns GC BPX90
90% Cyanopropyl Polysilphenylene-siloxane. For the fast separation of fragrances, aromatics, pesticides, PCB, isomers of fatty acid methyl esters.Bonded phaseHighly polarThermally stableAble to be solvent rinsed

Capillary columns GC CYDEX-B™
Permethylated Beta-Cyclodextrin (Chiral). Suitable replacement for: Cyclodex-B, Rt-BDEXm, LIPODEX C. Phase for the separation of chiral compound e.g. separation of enantiomeric compounds found in natural products.

Capillary columns GC SolGel-1ms™
100% Dimethyl Polysiloxane in a SolGel matrix. Suitable Replacement for: DB-1, DB-Petro, HP-1, HP-1MS, Rtx-1, Ultra-1, SPB-1, SPB-1 Sulfur, Petrocol DH, CP-Sil 5CB, VB-1, ZB-1, VF-1ms.Less bleedNon-polarHighly inertSame selectivity as BP1

Capillary columns HT5
5% Phenyl Polycarborane siloxane. Ultra-high temperature columns for simulated distillation applications, general hydrocarbon profiles, pesticides, herbicides and for GCMS applications.

Capillary columns HT8 / Fast PCB
8 % Phenyl Polycarborane-siloxane. Ultra high temperature columns for polychlorinated biphenyl compounds (PCB), nitro-substituted aromatics, polynuclear aromatic hydrocarbons, pesticides and herbicides.

Capillary columns SolGel-Wax
Polyethylene Glycol (PEG) in a SolGel matrix. Suitable replacement for: DB-Wax, Rtx- Wax, Stabilwax, HP20M, HP-Wax, HP-INNOWax, Supelcowax-10, AT-Wax, Nukol, CP, Wax 52CB, VB-WAX, ZB-WAX.Robust high-temperature column.Polar phaseLow bleed and inert

Capillary connections, PTFE
Straight fitting with capillary connections on both sides, incl. 2 x PFA fittings each for capillaries O.D. 1.6/2.2/3.2 mm.

Capillary cutter
For cutting capillaries and elastic tubes without reinforcement.Guide bores 1.6 / 2.3 / 3.2 / 3.8 / 4.2 mmIncl. spare blades


Capillary, methyl deactivated fused silica
Coated fused silica tubing for GC capillary applications.High homogeneityChemically inertStandard polyimide temperature resistance up to 380 °CPolyimide coating is chemically resistantLow dielectric constant, low dielectric lossImpermeable to all gases (except H2, He)Free of thermal hysteresisHigh intrinsic tensile strengthVery low thermal expansionUse with hydrofluoric acid, phosphoric acid, alkalis and alkali metal-containing compounds should be avoided, as this can lead to dissolution of the quartz glass and devitrification of the surface.


Capillary, phenyl deactivated fused silica
Coated fused silica tubing for GC capillary applications.High homogeneityChemically inertStandard polyimide temperature resistance up to 380 °CPolyimide coating is chemically resistantLow dielectric constant, low dielectric lossImpermeable to all gases (except H2, He)Free of thermal hysteresisHigh intrinsic tensile strengthVery low thermal expansionUse with hydrofluoric acid, phosphoric acid, alkalis and alkali metal-containing compounds should be avoided, as this can lead to dissolution of the quartz glass and devitrification of the surface.

Cellulose MN 300, TLC-ready-to-use plates cellulose coated
The primary field of application is the partition chromatography of polar substances such as amino acids, carboxylic acids or carbohydrates. The TLC-plates are available as glass plates, POLYGRAM® polyester sheets and ALUGRAM® aluminium sheets.Fiber length (95 %) 2-20 µmAverage degree of polymerization 400-500Specific surface according to Blaine 15000 cm2/g≤ 20 ppm Fe, 6 ppm Cu, 7 ppm PDichloromethane extract ≤ 0.25 %Residue on ignition at 850 °C ≤ 1500 ppmAvailable with or without fluorescent indicator (UV 254)

Centrifuge tubes for CHROMABOND® QuEchERS
QuEChERS method and pre-mixesWithin a few years after its devleopment by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food by GC-MS or LC-MS allowing rapid and cheap clean-up of strong matrix-contaminated samples.Standard clean-up of food samples10 g sample are homogenised with 10 ml acetonitrile. After adding the internal standard the sample is shaken with 4 g MgSO4 and 1 g NaCI and afterwards centrifuged. 1 ml of the supernantant is spiked with 25 mg CHROMABOND® Diamino and 150 mg MgSO4 and shaken again. After centrifugation the supernatant is injected into the GC/MS.Empty PP centrifuge tube with screw cap, without QuEchERS mixtures.

CHROMABOND® Alox A / Alox N / Alox B
aluminium oxide, acidic, neutral, basicaluminium oxide, high purity, pore volume 0.90ml/g, particle size 60 to 150µm, specific surface 150m²/g, acidic, pH 4 ± 0.5, recommended application: together with phase SA for PCB and pesticides.Alox A: acidic, pH 4 ± 0.5Alox N: neutral, pH 7 ± 0.5Alox B: basic, pH 9.5 ± 0.5

CHROMABOND® C18
Octadecyl modified silica phase for SPE, not endcappedBase material silica, pore size 60 Å, particle size 45 µm for C18, specific surface 500 m²/g, pH stability 2 to 8 octadecyl phases, not endcapped, carbon content 14 % possesses more free silanols (SiOH), which allow secondary interactions with polar groups of the analytes.Recommended applications: non-polar compounds, pesticides.