
Syringe filter CHROMAFIL®, regenerated Cellulose (RC)
The syringe filters are used for filtration of suspended matter from liquid samples and are certified for HPLC. Standard CHROMAFIL syringe filters are color coded. CHROMAFIL Xtra syringe filters are labeled for method validation and certification. All CHROMAFIL syringe filters are autoclavable (121 °C and 1.1 bar for 30 min).Hydrophilic membrane with very low adsorption for aqueous and organic/aqueous liquids i.e. polar and medium polar sample solutions. Binding capacity for proteins 84µg/25mm filter.

Syringe filter CHROMAFIL®, regenerated Cellulose with glass fibre prefilter (GF/RC)
Hydrophilic membrane for filtration of aqueous and organic/aqueous liquids, i.e. polar and medium polar sample solutions, for solutions with a high load of particulate matter or for highly viscous solutions.
Syringe Filter for HPLC
For small sample volumes. With Luer Lock inlet and Luer outlet. The type of membrane is indicated on the syringe filter.17 mm filter diameterColor codedDead volume < 0,29 ml

Syringe filter Minisart® HY
Minisart HY with hydrophobic PTFE membrane for oily solutions or gases. Housing made of MBS.

Syringe filter Minisart® HY
Housing MBS. HY (hydrophobic PTFE), for Venting and Gas Filtration.

Syringe filter Minisart® NML Plus, GF+SFCA / GF
The only difference between the Sartorius Minisart® NML Plus (Glass-fibre / Cellulose acetate) and the standard Minisart® NML is an additional glass fibre pre-filter which enables a greater filtration volume for highly particle-laden liquids. Sartorius Minisart®-GF (Glass-fibre, 0.7 µm² particle retention) contains a single, binding agent-free, glass fibre pre-filter for ultrafiltration. With a support achievement of 99 % for 40 µm spherical particles.

Syringe filter Minisart® NML, SFAC
Housing MBS. SFCA / CA (Surfactant-free Cellulose Acetate) membrane. For sterile, particle free, ultrapure filtration of small volumes of liquid up to approx. 100 ml. Colour coded and printed for easy membrane and pore size identification. With hydrophilic cellulose acetate membrane for minimum adsorption. Ready-to-use. With female luer-lock inlet, male luer slip outlet.

Syringe filter Minisart® NML, SFCA
Minisart® NML with surfactant-free cellulose acetate membrane (SFCA) for all aqueous solutions with a pH of 4 to 8.Housing made of MBSColour codedSterilisable by ethylene oxide (EO) or gamma irradiation

Syringe filter Minisart® NY / NY25 Plus
Housing PP. NY (Nylon) and NY25 Plus (Glass Fiber 0.7 µm² + Nylon).
Syringe filter Minisart® Ophthalsart
Housing MBS. Hydrophilic SCFA membrane. Suitable for particle removal and sterile filtration of aqueous liquids.
Syringe filter Minisart® PES
Housing PP. Syringe filter for sterile filtration over a wide pH range. Asymmetric membrane made of polyethersulfone for best flow performance and low adsorption.

Syringe filter Minisart® RC
Housing PP. Regenerated cellulose (RC). Ready-to-use units with a hydrophilic, solvent-resistant membrane made of regenerated cellulose, making sample preparation quick and easy. Suitable for aqueous/organic solutions.
Syringe filter Minisart® SRP
The coating-free hydrophobic PTFE membrane is suitable for removal of particles and microorganisms from liquids, gases and harsh chemicals.Housing made of PPLow adsorptionPrinted for easy membrane and pore size identification

Syringe filter Minisart® SRP, PTFE
Housing PP. With a chemical-resistant, hydrophobic PTFE membrane for high purification of solvents or aggressive liquids in HPLC or GC analysis. Low adsorption.

Syringe filter Nalgene™ nylon
This is a rather hydrophilic membrane; it is recommended for filtration of aqueous and organic/aqueous medium polar liquids.Excellent chemical compatibility with esters, bases and alcohols.Sterile filters individually blister-packed.
Syringe Filter Nalgene™ PES
For sterile filtration and purification of aqueous cell culture media
Syringe filter Nalgene™, SFCA / CA
For the filtration of biological and immunological samples, cell culture fluids, cellular solutions and biological fluids and for laboratory applications with aqueous and non-aqueous liquids, as well as for gases.

Syringe Filter, regenerated cellulose
High resistance in filtration and sterilisation of aqueous and organic samples in HPLC and GC applications.Regenerated cellulose membrane, hydrophilicResistant to almost all solvents and aqueous solutions in pH range 3-12Sterilisation and clarification of cell and protein solutions and biological fluids without loss of proteinsHousing material: PolypropyleneFitting inlet: Female Luer-LockFitting outlet: Male Luer-Slip
Syringe filters Acrodisc™ PSF, glass fiber (GF)
High-performance syringe filters can be used for general clarification or for application-specific purposes such as dissolution, HPLC, and IC. Specially developed for use in automated and semi-automated systems. The robust PP filter housing can withstand high operating pressures. With female Luer lock inlet and male Luer slip outlet.High-performance syringe filters can be used for general clarification or for application-specific purposes such as dissolution, HPLC, and IC. Specially developed for use in automated and semi-automated systems. The robust PP filter housing can withstand high operating pressures. With female Luer lock inlet and male Luer slip outlet.
Syringe filters Acrodisc™ PSF, glass fiber (GF), AutoPack
High-performance syringe filters can be used for general clarification or for application-specific purposes such as dissolution, HPLC, and IC. Specially developed for use in automated and semi-automated systems. The robust PP filter housing can withstand high operating pressures. With female Luer lock inlet and male Luer slip outlet.The syringe filters are pre-stacked in tubes in the AutoPack packaging. The carousel of the automatic filter changer can be loaded directly with these tubes.
Syringe filters Acrodisc™ PSF, nylon
High-performance syringe filters can be used for general clarification or for application-specific purposes such as dissolution, HPLC, and IC. Specially developed for use in automated and semi-automated systems. The robust PP filter housing can withstand high operating pressures. With female Luer lock inlet and male Luer slip outlet.Excellent chemical compatibility with esters, bases, and alcohols. No pre-wetting required.
Syringe filters Acrodisc™ PSF, nylon, AutoPack
High-performance syringe filters can be used for general clarification or for application-specific purposes such as dissolution, HPLC, and IC. Specially developed for use in automated and semi-automated systems. The robust PP filter housing can withstand high operating pressures. With female Luer lock inlet and male Luer slip outlet.Excellent chemical compatibility with esters, bases, and alcohols. No pre-wetting required. The syringe filters are pre-stacked in tubes in the AutoPack packaging. The carousel of the automatic filter changer can be loaded directly with these tubes.
Syringe filters Acrodisc™ PSF, regenerated cellulose (RC)
High-performance syringe filters can be used for general clarification or for application-specific purposes such as dissolution, HPLC, and IC. Specially developed for use in automated and semi-automated systems. The robust PP filter housing can withstand high operating pressures. With female Luer lock inlet and male Luer slip outlet.High-performance syringe filters can be used for general clarification or for application-specific purposes such as dissolution, HPLC, and IC. Specially developed for use in automated and semi-automated systems. The robust PP filter housing can withstand high operating pressures. With female Luer lock inlet and male Luer slip outlet.
Syringe filters Acrodisc™ PSF, regenerated cellulose (RC) with glass fiber prefilter
High-performance syringe filters can be used for general clarification or for application-specific purposes such as dissolution, HPLC, and IC. Specially developed for use in automated and semi-automated systems. The robust PP filter housing can withstand high operating pressures. With female Luer lock inlet and male Luer slip outlet.High-performance syringe filters can be used for general clarification or for application-specific purposes such as dissolution, HPLC, and IC. Specially developed for use in automated and semi-automated systems. The robust PP filter housing can withstand high operating pressures. With female Luer lock inlet and male Luer slip outlet.