NMR tubes, 5 mm, DURAN®, Professional
NMR tubes are available, according to requirement, in three accuracy classes. The correct tube can be selected depending on magnetic field and spin. The tubes are noteworthy for their close tolerances and accuracy, especially to their straightness, wall thickness and wall thickness distribution. Consequently, quick and accurate test results are achievable. With retrace code.For professional use in industry and research in the medium and high resolution area of NMR spectroscopy.

NMR Tubes, 5 mm, Wilmad, Precision
Thin-walled Precision NMR tubes. To maximize Signal-Noise-Ratio, Precision NMR tubes have minimal paramagnetic impurities that would impact shimming. For experiments requiring critical shimming quality (high/ultrahigh field, nonspinning, multi-dimensional, multi-nuclei, DNP experiments and studies involving biological samples).Made from borosilicate glass, ASTM E438 Type 1 Class AHydrolytic class 1Inner surface is resistant to strong acid and base at ambient temperatureFor temperatures up to 230 °C and within a temperature step of 120 °CInclude disposable caps
NMR Tubes, 5 mm, Wilmad, Precision LPV
Wilmad’s low pressure/vacuum (LPV) tubes are ideal for anaerobic and gas-tight NMR experiments and offers a flame-free sealing solution for air sensitive or volatile liquid samples. LPV Tubes consist of an NMR tube with the threaded glass section sealed on, 5 mm Pyrex® vacuum adapter, 5 mm PTFE vacuum lock valve and piston assembly.Robust sealing system allows pressure buildup inside the sampleGreaseless PTFE piston with 100 % contaminationfree sealSuitable for use in spinning experiments

NMR Tubes, 5 mm, Wilmad®, High Throughput
The thin-walled high-throughput Wilmad® NMR tubes have an average camber of 60 microns to guarantee the clarity of the spectrum for small molecule (MW <250) samples up to 600 MHz. Designed for routine use in most low to mid field NMR spectrometers.Made from borosilicate glass, ASTM E438 Type 1 Class B standardCamber and concentricity values listed are the Total Indicator Reading (TIR)Includes disposable capsWG-1000-7-SJ is supplied with authentic Bruker SampleJet cap

NMR tubes, 5mm, DURAN®, Scientific
NMR tubes are available, according to requirement, in three accuracy classes. The correct tube can be selected depending on magnetic field and spin. The tubes are noteworthy for their close tolerances and accuracy, especially to their straightness, wall thickness and wall thickness distribution. Consequently, quick and accurate test results are achievable. With retrace code.For scientific use with high value samples and optimum substance exploitation in the highest resolution range of NMR spectroscopy.

NMR tubes, diameter 3 and 5 mm borosilicate glass 3.3, standard
The NMR tubes are produced with high precision. They are suitable for routine measurements, high-throughput measurements or NMR systems with autosampler at measurement frequencies up to 600 MHz. The tubes are manufactured from borosilicate glass 3.3 which is conform to USP Type I and ASTM E438, Type I, Class A. Please order closing caps separately.

NMR tubes, diameter 3 and 5 mm, borosilicate glass 3.3, with UV protection
These tubes coloured by silver ion diffusion are particularly suitable for handling UV-sensitive substances. The tubes are manufactured from borosilicate glass 3.3 which is conform to USP Type I and ASTM E438, Type I, Class A. They are supplied with a green cap.

NMR Tubes, diameter 5 mm, borosilicate glass 3.3, High Precision
The High Precision NMR tubes are manufactured with high accuracy and excellent straightness and concentricity. They are particularly suitable for quantitative measurements and measurements in spectrometers with high measurement frequencies above 600 MHz up to the highest available field strengths above 1 GHz. The tubes are made of borosilicate glass 3.3, which complies with USP Type I and ASTM E438, Type I, Class A requirements. NMR tubes are supplied without caps, please order caps separately.

NMR tubes, length 100 mm, for Bruker MATCH™ system
These NMR tubes were developed with the special length of exactly 100 mm and are thus specifically adjusted for the Bruker MATCH™ system.
NMR Tubes, Wilmad, Precision, with screw cap
The thin-walled NMR tubes are used for degassing samples and can maintain a vacuum of >10-4 Torr. Supplied with open screw cap and septum.
NUCLEOGEL® SUGAR 810 Ca
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyValco type columns for separation of mono-, di- and oliogosaccharides - USP L19 eluent in column water.
NUCLEOGEL® SUGAR 810 H
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyValco type columns for separation of sugars, sugar alcohols and organic acids - USP L17 eluent in column 0.01 N H2SO4

O-rings CRS ONE, FKM
O-rings made of FKM for sealing between the inlet liner and GC injection port. They prevent gas leaks and ensure a uniform flow path through the inlet.Pre-cleaned and conditioned to minimize potential active sites and system contaminationResistant to high temperatures and chemical exposureCompatible with multiple devicesMax. injector temperature 300 °C

Omnifix® raw and blister syringes with catheter tip
Highly transparent barrelHigh contrast blue graduationPiston with double sealing ring for slow aspiration and injectionWith a central catheter hubPolypropylene syringe barrel and syringe plungerSmooth-running piston plug made of synthetic rubber with double sealing ringLatex-freeSterile, single packed

OPTIMA® 1 high performance capillary columns for GC
100% dimethylpolysiloxanenonpolar phase separation of components according to boiling points thick film columns ≥3µm film are especially recommended for solvent analysis.Similar phases: Permabond® SE-30, OV-1, DB-1, SE-30, HP-1, SPB-1, CP-Sil 5 CB, Rtx-1, 007-1, BP1, MDN-1, AT-1, ZB-1, OV-101.For columns with 0.25 to 0.32mm ID and films <3µm the max. temperature for isothermal operation is 340°C, the max. temperature for short isotherms in a temperature programme is 360°C.For 0.53mm ID columns with films <3µm the max. temperatures are 320 and 340°C, resp. for thick film columns with films ≥3µm the max. temperatures are 300 and 320 °C, resp.Custom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa, and thus protected from atmospheric oxygen. Additionally, we supply the corresponding test mixture with each column.

OPTIMA® 1 MS Accent ultra-low bleed capillary columns for GC
100 % dimethylpolysiloxanenonpolar phase with ultra-low bleeding, ideal for ion trap and quadrupol MS detectors increased sensitivity due to an unmatched low background level perfect inertness for basic compoundssolvent rinsing for removal of impurities applicableapplication areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analysessimilar phases: Ultra-1, DB-1 MS, HP-1 MS, Rtx-1 MS, Equity™1, AT-1 MS, VF-1 MS, CP-Sil 5 CB MSmax. temperature for isothermal operation 340 °C, max. temperature for short isotherms in a temperature programme 360 °CEach column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.

Optima® 17 capillary columns for GC
phenylmethylpolysiloxane (50 % phenyl)medium polar phasepreferred applications: steroids, pesticides, drug analysesUSP G3similar phases: OV-17, DB-17, HP50+, HP17, SPB-50, SP-2250, Rtx-50, CP-Sil 24 CB, 007-17, ZB50 max. temperature for isothermal operation: 320°C, max. temperature for short isotherms in a temperature programme: 340°C, for 0.53mm ID columns the max. temperatures are 300 and 320°C, resp.In addition to this standard programme we will be happy to supply columns custom-made to your specifications.

Optima® 1701 capillary columns for GC
14 % Cyanopropyl-phenyl - 86 % Dimethylpolysiloxane USP G46medium polar phasespecial selectivity due to high cyanopropyl contentreference column for structure identification, e.g. in combination with Optima 5film thickness 1 µm for solvent analysessimilar phases: OV-1701, DB-1701, CP?Sil 19 CB, HP-1701, Rtx-1701, SPB-1701, 007-1701, BP10, ZB-1701max. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°CCustom-made columns to your specifications on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa, and thus protected from Additionally, we supply the corresponding test mixture with each column.

OPTIMA® 225 capillary columns for GC
50% cyanopropylmethyl - 50% phenylmethylpolysiloxaneUSP G7 / G19middle polar phaserecommended for fatty acid analysessimilar phases: DB-225, HP-225, OV-225, Rtx-225, CP-Sil 43, 007-225, BP225max. temperature for isothermal operation: 260°C, max. temperature for short isotherms in a temperature programme: 280°CCustom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.

Optima® 5 Amine GC capillary columns for amine separation
especially deactivated for the analysis of polyfunctional amines such as ethanolamines, amino-functionalised diols and similar compounds, which are important base materials in industrial chemistry, and shows strong tailing on standard-deactivated columns; similar phases: Rtx-5 Amine, PTA-5; USP G27 / G36; improved linearity for analyses of active components at trace levels: no amine absorptions even for aliphatic and aromatic amines at concentrations of 100 pg/peak; tested with the Optima® Amine test mixture, which among others also contains diethanolamine and propanol-pyridine (this test mixture is supplied with each column). Max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°C.

OPTIMA® 5 capillary columns for GC
5% phenyl - 95% dimethylpolysiloxane USP G27, G36 nonpaolar standard phase with large range of application similar phases: Permabond® SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32mm ID and films <3µm the max. temperature for isothermal operation is 340°C, the max. temperature for short isotherms in a temperature programme is 360°C for 0.53mm ID columns with films < 3µm the max. temperatures are 320 and 340°C, resp. for thick film columns with films ≥ 3µm the max. temperatures are 300 and 320°C, resp.Further lengths available on request.Custom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.

OPTIMA® 5 MS Accent capillary columns for GC
silarylene phaseWith polarity similar to a 5 % diphenyl -95 % dimethylpolysiloxane phase.USP G27, G36Lowest column bleed, nonpolar phase, ideal for ion trap and quadrupol MS detectors solvent rinsing for removal of impurities applicableApplication areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analysessimilar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MSMax. temperature for isothermal operation: 340 °C,Max. temperature for short isotherms in a temperature programme: 360 °Cfor cloumns with film thicknesses > 5.5 µm the max. temperatures are 320 and 340 °CEach column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.

OPTIMA® 5 MS capillary columns for GC
5% diphenyl - 95% dimethylpolysiloxanenonpolar phase with low bleeding, deal for GC/MS and ECD applications and general analyses at trace level perfect inertness for basic compounds.Similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS.max. temperature for isothermal operation: 340°C, max. temperature for short isotherms in a temperature programme: 360 °CCustom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.