Safety Waste Caps, S 70/71
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, hose olive

Safety Waste Caps, S 70/71, with grounding connection
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, grounding connection

Safety Waste Caps, S 90
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, hose olive

Safety Waste Caps, S 90, with grounding connection
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, hose olive, grounding connection

Safety Waste Caps, S 95
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, hose olive

Safety Waste Caps, with electronic level control
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Electronic level control with floater and signal cable for connecting with electronic signal boxes.

Safety Waste Caps, with mechanical level control
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.The integrated float warns in time if the container is overfilled. Perfect for containers of opaque material, where the fill level is not visible from the outside.

Safety Waste Caps, with mechanical level control, with ground connection
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.The integrated float warns in time if the container is overfilled. Perfect for containers of opaque material, where the fill level is not visible from the outside.

Safety Waste Collector, GL 45
The Safety Waste Collector connects capillaries and tubes of the HPLC system with the disposal system.Scope of supply:Safety Waste Collector, PFA-fittings for capillaries, tube connector for tube with (ID) 5,0 - 11,5 mm, labeling field

SafetyWasteCaps, V2.0, S 60/61
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, PFA blind fittings, PTFE blind fittings, hose olives

Satellite extension for Safety Waste Caps V3.0
Satellite for connecting 4 capillaries (UNF 1/4" 28 G), 3 tube connectors (NPT 1/8") and an exhaust filter (GL 14). Scope of supply: Satellite (PTFE, white), PFA fittings: 4 x 1.6 mm (green), 4 x 2.3 mm (violet), 4 x 3.2 mm (blue), 4 blind plugs for capillary connections (PFA, transparent), 3 tube connectors for tubes with 5.0 - 11.5 mm ID (PP, blue), 3 blind plugs for tube connections (PTFE, white), 1 blind plug GL 14 (PTFE, white)

Satellite extension for Safety Waste Caps V3.0, electrostatic conductive
Satellite for connecting 4 capillaries (UNF 1/4" 28 G), 3 tube connectors (NPT 1/8") and an exhaust filter (GL 14).Scope of supply: Satellite (PTFE, black), PFA fittings: 4 x 1.6 mm (green), 4 x 2.3 mm (violet), 4 x 3.2 mm (blue), 4 blind plugs for capillary connections (PFA, transparent), 3 tube connectors for tubes with 5.0 - 11.5 mm ID (PP, blue), 3 blind plugs for tube connections (PTFE, white), 1 blind plug GL 14 (PTFE, white)

Screw caps HPLC, PTFE, GL 45
With 3 ports, for tubing outer diameter 3.2 mm, complete with 3 UNF 1/4" 28G ETFE plugs and seal (TFE / PP).

Septum adapters, PTFE
Threaded adapter to connect a septum cap with a capillary connector.

Set for continuous level control
For permanent level measurement. The signal box offers 4 freely configurable outputs for controlling external devices. The compact design and independent mains supply allow easy handling and installation even outside control cabinets.Automatic warning for 5 different levels freely selectableAccuracy of up to ± 0.5 mmProbe head: stainless steel 303/316LProbe tube: stainless steel 1.4571Probe length: 265 mmProbe tube Ø: 6 mmProtection class IP68Scope of supply: Signalbox UM-O-Ex with display unit, stainless steel sensor probe, cable with open ends, level sensor TORRIX Ex 6 B NT for Bypass without HART

Signal lamps for level control
Visual signal when the level is reachedWith magnetic holderCable length 3 m

Signalbox T5
LED's and acoustic alarm warn before the level of collection containers reaches the critical level. With mute / snooze function and interface for controlling external devices such as pumps or valves. For SCAT sensors and Safety Waste Caps with electronic level control.LED display5 sensor inputs and 6 potential-free outputsOperating temerature: 5 to 40 °C

Spiral tubing, PFA, for b.safe Caps and b.safe Waste Caps
Spiral tubing with tubing ends (1x 300 mm, 1x 150 mm) and PFA fittings for tubing O. D. 3,2 mm.

Suction filters, PE
Filter cartridges made of porous PE with a bore to be put on capillary tubing.

Suction filters, PFA
Suction filter with PTFE membrane to be put on capillary tubing.

Switchbox II
Control unit for SCAT Built-in Signalbox or Signalbox T1/T5. For controlling the automatic switchover between two collection containers. This allows disposal to take place over the weekend, for example, without having to empty or change containers in the meantime. Aditionally, SwitchBox can be used in any kind of automation circuit (pump, valve, etc. control).

Table distributor b.safe, PP, with magnet
Central waste collection from several HPLC systems. Capillaries and tubes are connected without kinks using the fittings (thread UNF 1/4“) and tube connectors (thread NPT 1/8“) included in the scope of supply. The liquid solvent waste flows off directly and residue-free via the vertical hole inside the table distributor. Easy attachment to the worktable, either by magnet or silicone-free adhesive pad.Central waste collection from several HPLC systems. Capillaries and tubes are connected without kinks using the fittings (thread UNF 1/4“) and tube connectors (thread NPT 1/8“) included in the scope of supply. The liquid solvent waste flows off directly and residue-free via the vertical hole inside the table distributor. Easy attachment to the worktable, either by magnet or silicone-free adhesive pad.

Table distributor b.safe, PP, with silicone-free adhesive pad
Central waste collection from several HPLC systems. Capillaries and tubes are connected without kinks using the fittings (thread UNF 1/4“) and tube connectors (thread NPT 1/8“) included in the scope of supply. The liquid solvent waste flows off directly and residue-free via the vertical hole inside the table distributor. Easy attachment to the worktable, either by magnet or silicone-free adhesive pad.Central waste collection from several HPLC systems. Capillaries and tubes are connected without kinks using the fittings (thread UNF 1/4“) and tube connectors (thread NPT 1/8“) included in the scope of supply. The liquid solvent waste flows off directly and residue-free via the vertical hole inside the table distributor. Easy attachment to the worktable, either by magnet or silicone-free adhesive pad.