Skip to main content Skip to search Skip to main navigation

Filter products

Capillary columns GC BPX70

Capillary columns GC BPX70

70% Cyanopropyl Polysilphenylene-siloxane. Able to be solvent rinsed. Industry standard column for fatty acid methyl esters, carbonhydrates, pharmaceuticals, GC/MS applications. Suitable alternative to: DB-23, Rtx-2330, SP-2330, CP-Sil 88, SP2380, HP-23.

Regular price: €0.00
Capillary columns GC BPX90

Capillary columns GC BPX90

90% Cyanopropyl Polysilphenylene-siloxane. For the fast separation of fragrances, aromatics, pesticides, PCB, isomers of fatty acid methyl esters.Bonded phaseHighly polarThermally stableAble to be solvent rinsed

Regular price: €0.00
Capillary columns GC CYDEX-B™

Capillary columns GC CYDEX-B™

Permethylated Beta-Cyclodextrin (Chiral). Suitable replacement for: Cyclodex-B, Rt-BDEXm, LIPODEX C. Phase for the separation of chiral compound e.g. separation of enantiomeric compounds found in natural products.

Regular price: €0.00
Capillary columns GC SolGel-1ms™

Capillary columns GC SolGel-1ms™

100% Dimethyl Polysiloxane in a SolGel matrix. Suitable Replacement for: DB-1, DB-Petro, HP-1, HP-1MS, Rtx-1, Ultra-1, SPB-1, SPB-1 Sulfur, Petrocol DH, CP-Sil 5CB, VB-1, ZB-1, VF-1ms.Less bleedNon-polarHighly inertSame selectivity as BP1

Regular price: €0.00
Capillary columns HT5

Capillary columns HT5

5% Phenyl Polycarborane siloxane. Ultra-high temperature columns for simulated distillation applications, general hydrocarbon profiles, pesticides, herbicides and for GCMS applications.

Regular price: €0.00
Capillary columns HT8 / Fast PCB

Capillary columns HT8 / Fast PCB

8 % Phenyl Polycarborane-siloxane. Ultra high temperature columns for polychlorinated biphenyl compounds (PCB), nitro-substituted aromatics, polynuclear aromatic hydrocarbons, pesticides and herbicides.

Regular price: €0.00
Capillary columns SolGel-Wax

Capillary columns SolGel-Wax

Polyethylene Glycol (PEG) in a SolGel matrix. Suitable replacement for: DB-Wax, Rtx- Wax, Stabilwax, HP20M, HP-Wax, HP-INNOWax, Supelcowax-10, AT-Wax, Nukol, CP, Wax 52CB, VB-WAX, ZB-WAX.Robust high-temperature column.Polar phaseLow bleed and inert

Regular price: €0.00
Capillary, methyl deactivated fused silica

Capillary, methyl deactivated fused silica

Coated fused silica tubing for GC capillary applications.High homogeneityChemically inertStandard polyimide temperature resistance up to 380 °CPolyimide coating is chemically resistantLow dielectric constant, low dielectric lossImpermeable to all gases (except H2, He)Free of thermal hysteresisHigh intrinsic tensile strengthVery low thermal expansionUse with hydrofluoric acid, phosphoric acid, alkalis and alkali metal-containing compounds should be avoided, as this can lead to dissolution of the quartz glass and devitrification of the surface.

Regular price: €0.00
Capillary, non deactivated fused silica

Capillary, non deactivated fused silica

Regular price: €0.00
Capillary, phenyl deactivated fused silica

Capillary, phenyl deactivated fused silica

Coated fused silica tubing for GC capillary applications.High homogeneityChemically inertStandard polyimide temperature resistance up to 380 °CPolyimide coating is chemically resistantLow dielectric constant, low dielectric lossImpermeable to all gases (except H2, He)Free of thermal hysteresisHigh intrinsic tensile strengthVery low thermal expansionUse with hydrofluoric acid, phosphoric acid, alkalis and alkali metal-containing compounds should be avoided, as this can lead to dissolution of the quartz glass and devitrification of the surface.

Regular price: €0.00

Derivatisation method development kit

For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.Which type of derivatisation is best suited for your sample (alkylation, silylation or acylation)? Test kit for determination of the optimum derivatisation.

Regular price: €0.00
Ferrules Graphite

Ferrules Graphite

High quality ferrules made of 100 % Graphite.

Regular price: €0.00

Ferrules, mini, Graphite/ Vespel®

High quality ferrules made of 15 % Graphite / 85 % Vespel®.

Regular price: €0.00
Gas and vapor sampler kit

Gas and vapor sampler kit

The gas and vapor sampler enables spot collection of environmental gas samples or low pressure gas streams in 200 cm3 impervious resealable bags. Ideal for field analysis.Scope of supply: Canister, bulb, 10 bags, marker pen, instructions

Regular price: €0.00
Gas chromatography flow meter GF500

Gas chromatography flow meter GF500

Convenient digital flow meter for the simple, accurate and repeatable measurement of flow in gas chromatographs. User friendly, handy design. Can be used with the carrier gases Air, Hydrogen, Nitrogen, Helium, Carbon dioxide, Argon and Argon/Methane. OLED display shows flow rate and further information. With pressure and temperature compensation. Suitable for columns with diameters of 100, 180, 200, 250, 320, 450, 530 and 750 µm.Measurement of flow rate, linear velocity and split ratioHigh resolution25 point calibration, traceable to National StandardsRechargeable batteryAuto power offScope of supply: Flow meter with case, tubings, tubing adapter fittings, tubing clips, tie-wraps, universal charger with USB connector, operation manual, calibration certificate.Please order adapters for direct connection to the detector separately.SpecificationsRange:0…500 ml/min. (0…300 ml CO2)Accuracy:0.4 ml/min. / ±2.5 %Resolution:0.1 ml/min.Operating temperature:15…35 °C, calibrated at 21±2 °CInlet pressure:max. 175 kPaDimensions:68 x 30 x 130 mmWeight:150 g

Regular price: €0.00
Gas filters

Gas filters

Gas filters are an essential part of GC analysis as contaminants in gases can significantly impact the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column and excessive bleed. The gas filter kit consists of a gas filter and a connection unit.Fast stabilization timesThe gas filter system consists of two key parts: the filters and the connecting unitThe connecting unit has inlet and outlet connectors for the gas linesThe connecting unit can be bench or wall-mountedCan be used in combination with other filtersIndicator color change tells you when to change your filter

Regular price: €0.00
Gas filters big trap

Gas filters big trap

Gas filters are an essential part of your GC analysis as contaminants in gases can significantly impact the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column and excessive bleed.Heavy-walled aluminium tubeHigh capacity filtersSintered stainless steel frits prevent particulate contaminationSpecificationsVolume:750 cm3Pessure rating:up to 17.2 bar

Regular price: €0.00
GC Capillary columns HYDRODEX β-6TBDM

GC Capillary columns HYDRODEX β-6TBDM

HYDRODEX cyclodextrin phases for enantiomer separationHeptakis-(2,3-di-O-methyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for γ-lactones, cyclopentanones, terpenes, esters, tartrates.Max. temperature for isothermal operation: 230 °CMax. temperature for short isotherms in a temperature programme: 250 °C

Regular price: €0.00
GC Capillary columns HYDRODEX β-TBDAC

GC Capillary columns HYDRODEX β-TBDAC

HYDRODEX cyclodextrin phases for enantiomer separationHeptakis-(2,3-di-O-acetyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for alcohols, esters, ketones, aldehydes, δ-lactones.Max. temperature for isothermal operation: 220 °CMax. temperature for short isotherms in a temperature programme: 240 °C

Regular price: €0.00
GC Capillary columns LIPODEX® E

GC Capillary columns LIPODEX® E

LIPODEX® cyclodextrin phase for enantiomer separationBase material: cyclic oligosaccharide consisting of eight glucose units bonded through α-1,4-linkages (y-cylodextrin) regioselective alkylation and acylation of the hydroxyl groups leads to a lipophilic phase, which is well suited for GC enantiomer analyses; important advantage: many compounds can be analysed without derivatisation (however, for certain substances enantioselectivity can be favourably influenced by formation of derivatives).Octakis-(2,6-di-O-pentyl-3-O-butyryl)-γ-cyclodextrin. Recommended for α-amino acids, α- and β-hydroxycarboxylic acid esters, alcohols (TFA), diols (TFA), ketones, pheromones (cyclic acetals), amines, alkyl halides, lactones.Max. temperature for isothermal operation: 200 °CMax. temperature for short isotherms in a temperature programme: 220 °C

Regular price: €0.00
GC Ferrules, Graphit/ Vespel®

GC Ferrules, Graphit/ Vespel®

High quality ferrules made of 15 % Graphite / 85 % Vespel®. 1/16" GC ferrule long.

Regular price: €0.00
GC Ferrules, Graphit/ Vespel®, Agilent style

GC Ferrules, Graphit/ Vespel®, Agilent style

High quality ferrules made of 15 % Graphite / 85 % Vespel®. 1/16" GC ferrule.

Regular price: €0.00

GC Ferrules, Graphit/ Vespel®, two-hole

High quality ferrules made of 15% Graphite / 85% Vespel®. 1/16" GC ferrule long.

Regular price: €0.00
High temperature septa

High temperature septa

Preconditioned PTFE/silicone rubber septa. Maximum operatin gtemperature: 212 °C.

Regular price: €0.00