Skip to main content Skip to search Skip to main navigation

Filter products

Septa for Agilent GC/EC

Septa for Agilent GC/EC

All Septa are made with a high grade silicone material to minimize needle coring. These new materials meet or exceed industry standards, giving you reassurance in the quality of your work. All of these Septa are durable with excellent resealing properties and excellent solvent resistance.EC = High Temperature Silicone Septa, for significantly longer injection life, low bleed and low injection port adhesion.

Regular price: €0.00
Septa for Agilent GC/HT

Septa for Agilent GC/HT

All Septa are made with a high grade silicone material to minimize needle coring. These new materials meet or exceed industry standards, giving you reassurance in the quality of your work. All of these Septa are durable with excellent resealing properties and excellent solvent resistance.HT = BTO Silicone Septa, Bleed and temperature optimized, combined with outstanding mechanical properties.

Regular price: €0.00

Silylation kit

For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.Which is the proper reagent for silylation?Test kit for determination of the optimum silylation.

Regular price: €0.00
Silylation reagents - BSTFA, SILYL-991

Silylation reagents - BSTFA, SILYL-991

For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.N,O-bis-trimethylsilyl-trifluoroacetamidem.w. 257.4, Bp 40°C (12mm Hg), density d20°/4° = 0.961BSTFA: R = CF3 powerful trimethylsilyl donor with approximately the same donor strength as the non-fluorinated analogue BSAadvantage of BSTFA over BSA: greater volatility of its reaction products (particularly useful for GC of some lower boiling TMS amino acids.BSTFA is nonpolar (less polar than MSTFA), and can be mixed with acetonitrile for improved solubility. For silylating fatty acid amides, hindered hydroxyls and other compounds, which are difficult to silylate (like secondary alcohols and amines), we recommend BSTFA + 1% trimethylchlorosilane (TMCS), available under the designation SILYL-991.Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture.The derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used immediately.

Regular price: €0.00
Silylation reagents - MSTFA

Silylation reagents - MSTFA

For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.N-methyl-N-trimethylsilyl-trifluoroacetamidem.w. 199.1, Bp 70 °C (75 mm Hg), density d20°/4° = 1.11MSTFA: R' = CF3, R" = CH3The most volatile trimethylsilyl amide available.Very strong TMS donor which does not cause any noticeable fouling of the FID burning chamber even after long-time measuring series.The already good solution characteristics can be improved by addition of submolar quantities of protic solvents (e.g. TFA for extremely polar compounds such as hydrochlorides) or pyridine (e.g. for carbohydrates).Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture.The derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used soon.

Regular price: €0.00
Syringes for GC autosampler from Agilent

Syringes for GC autosampler from Agilent

GC syringes for Agilent autosampler 7673, 7683 and 6850With fixed or removable needleTwo different needle diameter and tapered needlesHigh reproducibility, low carry-over

Regular price: €0.00
Syringes for GC autosampler from Agilent, gastight

Syringes for GC autosampler from Agilent, gastight

GC syringes for Agilent autosampler 7673, 7683 and 6850With fixed or removable needleTwo different needle diameter and tapered needlesHigh reproducibility, low carry-over

Regular price: €0.00
Syringes for GC autosampler from CTC

Syringes for GC autosampler from CTC

Syringes for CTC Analytics CombiPal and GC PAL. High reproducibility, low carry-over.

Regular price: €0.00
Syringes for GC autosampler from CTC / Thermo / Bruker (Varian)

Syringes for GC autosampler from CTC / Thermo / Bruker (Varian)

Syringes for CTC Analytics CombiPal and GC PAL. High reproducibility, low carry-over.

Regular price: €0.00
Syringes for GC autosampler from CTC / Thermo AS3000, AS2000, AS200/80

Syringes for GC autosampler from CTC / Thermo AS3000, AS2000, AS200/80

Syringes for CTC Analytics CombiPal and GC PAL. High reproducibility, low carry-over.

Regular price: €0.00
Syringes for GC autosampler from CTC / Thermo TriPlus

Syringes for GC autosampler from CTC / Thermo TriPlus

Syringes for CTC Analytics CombiPal and GC PAL. High reproducibility, low carry-over.

Regular price: €0.00
Syringes for GC autosampler from CTC / Thermo, gastight

Syringes for GC autosampler from CTC / Thermo, gastight

Syringes for CTC Analytics CombiPal and GC PAL.High reproducibility, low carry-overFor Thermo TriPlus

Regular price: €0.00
Syringes for GC autosampler from Perkin-Elmer

Syringes for GC autosampler from Perkin-Elmer

GC syringes for all Perkin-Elmer autosampler e.g. Clarus. High reproducibility, low carry-over.

Regular price: €0.00
Syringes for GC autosampler from Perkin-Elmer, gastight

Syringes for GC autosampler from Perkin-Elmer, gastight

GC syringes for all Perkin-Elmer autosampler e.g. Clarus. High reproducibility, low carry-over.

Regular price: €0.00
Syringes for GC autosampler from Shimadzu

Syringes for GC autosampler from Shimadzu

For Shimadzu AOC-14, AOC-17, AOC-20 and AOC-20i. Needle tip: cone.Article 6.205 989 with GT plunger.

Regular price: €0.00
Syringes for LC autosampler from CTC

Syringes for LC autosampler from CTC

Syringes for CTC Analytics HTS, HTC and LC PAL (needle tip: LC). Gastight.

Regular price: €0.00
Three-layer septa for GC inlet

Three-layer septa for GC inlet

Low density silicone was sandwiched between two high density silicone layers. Working temperature max. 200 °C.

Regular price: €0.00
Zero Air generators Precision Zero Air

Zero Air generators Precision Zero Air

Generates clean, dry and hydrocarbon-free air for FIDs in GC. Also meets the purity requirements for trace analysis.Fail-safe, continuous generation of zero airHydrocarbon content <0.05 ppmModular design and combination option with other PEAK Precision devicesMinimal maintenanceNo replacement of the catalyst chamber requiredCompatible with the Precision Air CompressorStatus displayScope of supply: Zero air generator, 3 m PTFE tubing, 1/4" compression fitting, 1/8" compression fitting, mains power cable for EU, UK and USSpecificationsHydrocarbon content:0.05 ppmPermissible ambient temperature:5 ... 35 °CPower supply:110/230 V, 50/60 HzWarranty:1 year

Regular price: €0.00