Pump drive Hei-FLOW Core 120
€0.00
Product information "Pump drive Hei-FLOW Core 120"
- Feed direction reversible
- For safety in unattended continuous operation, the motor will be switched off in case of an overload situation to prevent overheating
- Pump heads with convex rollers for cell protection are available for use in cell biology
The flow rate depends on the used pump head. The pump head is not included. Please order separately.
| Accuracy speed: | ±2 % |
|---|---|
| Accuracy speed Number: | 2 % |
| Depth: | 256 mm |
| Dimensions (WxDxH): | 166 x 256 x 225 mm |
| Flow rate: | 0.005 ... 861 ml/min |
| Height: | 225 mm |
| IP code: | IP 54 |
| Manufacturer Article Number: | 523-50010-00 |
| Max. flow rate: | 861 ml/min |
| Max. speed: | 120 1/min |
| Max. voltage: | 240 V |
| Min. flow rate: | 0.005 ml/min |
| Min. speed: | 10 1/min |
| Min. voltage: | 110 V |
| Plug type: | EU |
| Power supply: | 110 ... 240 V, 50/60 Hz |
| Power supply frequency: | 50/60 Hz |
| Rated capacity: | 100 W |
| Speed: | 10 ... 120 1/min |
| Type: | Hei-FLOW Core 120 |
| Type of auxiliary energy: | Mains connection |
| Weight: | 7.6 kg |
| Width: | 166 mm |
0 of 0 reviews
Average rating of 0 out of 5 stars
Login
Other customers also bought

Feed pump for reproducible results. The speed is adjustable with the analog control knob, and the electronic speed control guarantees constant speeds even under changing loads.Speed, direction of rotation and on/off function is controllable with an analog interfaceA press of the max. button accelerates the filling and draining of the tubingFor safety in unattended continuous operation, the motor will be switched off in case of an overload situation to prevent overheatingOptional pump heads with convex rollers for cell protection are available for use in cell biologyOptional footswitch to operate pump drive in closed fume hoods and to facilitate filling operationsThe flow rate depends on the used pump head. The pump head is not included. Please order separately.With an optional pump head adapter the Hei-FLOW Expert 120 can be upgraded for multi-channel operation.

Dosing and Feeding pumps for reproducible results. Flow characteristics in combination with various tubing diameters are pre-programmed for accurate flow rate numbers. With freely selectable process parameters.Speed, direction of rotation and on / off function is controllable with an analog interface or digital with built-in RS232 interfacePre-programmed flow characteristics are shown in the displayDigital read-out of Speed, Tubing diameter, Flow rate, Dosing volume, Interval dosing, Pause functionWith buttons for selecting all process parametersEasy calibration of flow volume and flow rateSmooth start operation prevents from spills and splashing mediaA press of the max button accelerates the filling and draining of the tubingFor safety in unattended continuous operation, the motor will be switched off in case of an overload situation to prevent overheatingOptional foot switch to operate pump drive in closed fume hoods and to facilitate filling operationsPump heads with convex rollers for cell protection are available for use in cell biologyThe pump head is not included. Please order separately.With an optional pump head adapter the Hei-FLOW Ultimate 120 can be upgraded for multi-channel operation.

Dosing and Feeding pumps for reproducible results. Flow characteristics in combination with various tubing diameters are pre-programmed for accurate flow rate numbers. With freely selectable process parameters.Speed, direction of rotation and on / off function is controllable with an analog interface or digital with built-in RS232 interfacePre-programmed flow characteristics are shown in the displayDigital read-out of Speed, Tubing diameter, Flow rate, Dosing volume, Interval dosing, Pause functionWith buttons for selecting all process parametersEasy calibration of flow volume and flow rateSmooth start operation prevents from spills and splashing mediaA press of the max button accelerates the filling and draining of the tubingFor safety in unattended continuous operation, the motor will be switched off in case of an overload situation to prevent overheatingOptional foot switch to operate pump drive in closed fume hoods and to facilitate filling operationsPump heads with convex rollers for cell protection are available for use in cell biologyThe pump head is not included. Please order separately.This pump drive is only suitable for use with single-channel pump heads.

Feed pump for reproducible results. The speed is adjustable with the analog control knob, and the electronic speed control guarantees constant speeds even under changing loads.Speed, direction of rotation and on/off function is controllable with an analog interfaceA press of the max. button accelerates the filling and draining of the tubingFor safety in unattended continuous operation, the motor will be switched off in case of an overload situation to prevent overheatingOptional pump heads with convex rollers for cell protection are available for use in cell biologyOptional footswitch to operate pump drive in closed fume hoods and to facilitate filling operationsThe flow rate depends on the used pump head. The pump head is not included. Please order separately.This pump drive is only suitable for use with single-channel pump heads.
Set

Feed pump for standard applications. The speed is adjustable with the analog control knob and stays constant even under changing loads.Feed direction reversibleFor safety in unattended continuous operation, the motor will be switched off in case of an overload situation to prevent overheatingPump heads with convex rollers for cell protection are available for use in cell biologyThe flow rate depends on the used pump head. The pump head is not included. Please order separately.Scope of supply: Pump drive, adapter for multi-channel pump heads
Accessories

These pump drives are able to be configured for multi-channel use: Value 01, Advantage 01, Precision 01Increased output by running up to 12 individual cassettes on one single pump drive and pump head systemSeparate metering into multiple vessels with different feed rates at the same time by using different tubing dimensions to adjust flow ratesEasy and quick tubing changeIn addition to standard pump heads which feature a 4 roller system, 8 roller pump heads are available for low pulsationEasy change of cassettes, even during operationCassettes adjustments and changes are simple due to click systemWith possibility to upgrade the pump drive with an adapter for multi-channel operationAccepts 8 cassettes medium or 4 cassettes large4-roller design

Fast and convenient tube changesLow pulsation due to 5 roller systemPump head features ball bearingsRollers made of stainless steelFor tubes with a 1.6mm or 2.5mm wall thickness (wt)Depending on drive and tubing, the flow rate ranges from 0.38 to 3436 ml per minute

Recommended for standard applicationsConvex rollers do not squeeze or crush organic cell culturesPump head features ball bearingsRollers made of stainless steel and polyamideFor tubes with a 1.6mm or 2.5mm wall thickness (wt)Depending on drive and tubing, the flow rate ranges from 2.0 to 4151 ml per minute

These pump drives are able to be configured for multi-channel use: Value 01, Advantage 01, Precision 01Increased output by running up to 12 individual cassettes on one single pump drive and pump head systemSeparate metering into multiple vessels with different feed rates at the same time by using different tubing dimensions to adjust flow ratesEasy and quick tubing changeIn addition to standard pump heads which feature a 4 roller system, 8 roller pump heads are available for low pulsationEasy change of cassettes, even during operationCassettes adjustments and changes are simple due to click systemWith possibility to upgrade the pump drive with an adapter for multi-channel operationAccepts 12 cassettes smallBuilt-in reduction gear allows feeding of smallest quantities8 rollers minimizing pulsation

These pump drives are able to be configured for multi-channel use: Value 01, Advantage 01, Precision 01Increased output by running up to 12 individual cassettes on one single pump drive and pump head systemSeparate metering into multiple vessels with different feed rates at the same time by using different tubing dimensions to adjust flow ratesEasy and quick tubing changeIn addition to standard pump heads which feature a 4 roller system, 8 roller pump heads are available for low pulsationEasy change of cassettes, even during operationCassettes adjustments and changes are simple due to click systemWith possibility to upgrade the pump drive with an adapter for multi-channel operationAccepts 4 cassettes small8 rollers for low pulsation