Absorbance test plate for microplate spectrophotometer INNO
The absorbance test plate is specifically designed to check the performance of the device by controlling the linearity, accuracy, and alignment of the device.






Accessories to Flame Photometer FF-200
Please Note: These products will only operate with the correct type of air compressor and gas regulator as specified below.

Autoanalyser cups for Technicon® analysers
PS. Conical base. Sample cups for use in autoanalysers.


Caps for TrayCell
Traditional spectrophotometrical analysis of nucleic acids is carried out in 10mm cuvettes. Modern drop analysis uses light paths of 1mm and 0.2mm and it is thus not necessary to dilute the sample. In applications with very high or very low DNA concentrations these light paths are often no longer sufficient. When using the TrayCell from Hellma Analytics simply adjust the light path by exchanging the cap. Cap with integrated mirror to change the light path.

Cell storage container, Küvibox 2
Dust-proof, rigid container for storing clean cells. Accommodates cells up to 55mm in height. Cells are immediately ready for use when required.Küvibox 1 holds up to 16 x 10mm path length cellsKüvibox 2 holds up to 8 x 10mm and up to 4 x 20mm path length cells.

Cells for Absorption Measurement, Flow-Through Measurement, UV-range
Optical material: QS: Quartz glass High Performance, wavelength range: 200 - 2500 nm.OS: Special Optical Glass, wavelength range: 320 - 2500 nm.* M 6 x 1 and FEP tubes (outside diameter 1.9mm, inner diameter 1.1mm, length 500mm)
Cells for Absorption Measurement, NIR-range
300 Wavelength Range: 200nm - 3500nmOptical material: Quartz glass Extended Range

Cells for Absorption Measurement, UV-range
To maintain constant good measurement results, a regular review of the accuracy of the spectrophotometer is required. With the use of certified reference materials from Hellma Analytics, you make sure that your equipment qualifications meet the requirements of the pharmacopoeias and fulfill your internal quality requirements, at the same time you reach the international comparability of your measurement results. The certified reference materials (calibration standards) of the DIN EN ISO 17025 accredited Hellma Analytics calibration laboratory are traceable to the primary standards of NIST (National Institute of Standards and Technology) and meet the requirements of the major pharmacopoeias (e.g. EP, DAB, USP).Your benefits: High quality of the measurement resultsInternational comparability of measurement resultsMeeting the requirements of the major pharmacopoeias (EP, DAB, USP)Results traceable to NIST primary standards30 years warranty on the reference materialsScope of delivery: Certified reference materials (Calibration Standards) in quality storage boxDAkkS Calibration Certificate (DIN 17025)Handling guidelinesWavelength Range: 200nm - 2500 nm. Optical material: Quartz glass High PerformanceM= Measuring volume* black side walls and base** with silicone rubber seal and with ISO thread GL 14*** for magnetic stirring bars

Cells for Absorption Measurement, Vis-range
Wavelength Range:Optical material:260nm - 2500nmHOQ 310H (UV)320 nm - 2500 nm Special optical glass (OS)360 nm - 2500 nm Optical glass (OG)

Cells for Fluorescence Measurement, UV-range
Wavelength Range: 200 nm - 2500 nmOptical material: Quartz glass High Performance

Cells for light scattering measurements, UV-range
Wavelength: 200nm - 2500nmOptical material: Quartz glass High Performance