
TFF cassettes Vivaflow® SU, serial run
Tangential flow filtration (TFF) cassettes for ultrafiltration and diafiltration of medium sample volumes. Specially designed for applications in research and development laboratories. High-performance membranes with a membrane area of 50 cm2 ensure maximum recovery. No flushing or cleaning required.For the serial run of both cassettes with 500 to 1000 ml volume.Scope of supply: 2 x cassettes, 1 x feed tubing, 1 x serial connector, 2 x permeate tubing, 1 x pressure indicator, 1 x retentate tubing with restrictor

TFF cassettes Vivaflow® SU, serial run, 0.2 µm
Tangential flow filtration (TFF) cassettes for ultrafiltration and diafiltration of medium sample volumes. Specially designed for applications in research and development laboratories. High-performance membranes with a membrane area of 50 cm2 ensure maximum recovery. No flushing or cleaning required.For the serial run of both cassettes with 500 to 1000 ml volume.Scope of supply: 2 x cassettes, 1 x feed tubing, 1 x serial connector, 2 x permeate tubing, 1 x pressure indicator, 1 x retentate tubing with restrictor

Transfer membrane, nitrocellulose
Pure Nitrocellulose transfer membrane for all protein or immunoblotting applications. The high sensitivity and low background ensures excellent results in all transfers. Compatible with all detection systems. BSA binding capacity up to 100µg/cm2.Signal word:H phrases:P phrases:

Transfer membrane, PVDF
Hydrophobic Polyvinylidene Fluoride (PVDF) transfer membrane with high binding capacity and low background. Ideal for use in protein binding applications such as Western blots, solid phase assays and immunoblotting procedures. BSA binding capacity up to 125 µg/cm2

Transfer membrane, supported nitrocellulose
Supported Nitrocellulose transfer membranes combine the binding characteristics of nitrocellulose membranes with the strength of nylon membranes. These membranes are used for DNA/RNA transfers requiring low background or for multiple hybridizations. For use with chemiluminescence and radiographic detection systems. BSA binding capacity up to 100 µg/cm2.Signal word:H phrases:P phrases:
Transfer membranes Amersham Hybond LFP, PVDF
Low fluorescent, hydrophobic blotting membrane for protein transfer. Optimized for fluorescence detection in Western blotting applications.Protein binding capacity over 200 µg/cm2Higher sensitivity due to low background fluorescenceCompatible with many blocking agents, transfer buffers and total protein blot stainsAvailable in the standard precut sizes for laboratory applications
Transfer membranes Amersham Hybond P, PVDF
Hydrophobic membrane with high physical strength, suitable for stripping and reprobing. For use with standard colourimetric and chemiluminescent detection methods for proteins of < Mr 20 000.Protein binding capacity over 200 µg/cm2High protein retention even after harsh washing stepsAvailable in popular sizes for laboratory application

Transfer membranes Amersham Hybond SEQ, PVDF
Hydrophobic Western blotting membrane specifically designed for protein sequencing applications and solid-phase amino acid analysis.High protein binding capacityChemical resistance needed for N-terminal sequencingHigh protein retention even after harsh washing stepsMinimizes "blow-through" and increases protein bindingAvailable in popular sizes for laboratory application
Transfer membranes Amersham Protran
Pure nitrocellulose with extreme mechanical stability - gives excellent useability. For protein transfer and DNA/RNA transfer techniques. Optimum signal/background ratio.

Transfer membranes Optitran®
Webbing reinforced nitrocellulose.High mechanical stability for multiple hybridisations.
Transfer System Nytran SuPerCharge Turboblotter™, refill pack
The TurboBlotter is very easy to set up, and works without power or vacuum source. Offers high resolution transfer of DNA and RNA with unique downward capillary transfer in one hour. Reusable blotting device requires less buffer and blotting paper. Scope of supply: 5 transfers


U96 Immuno™ Plates, PS, with Immulon™ 1B surface
Clear plates with excellent optical quality and round well bottom.Immulon™ 1B serve to absorb hydrophobic molecules.
U96 Immuno™ Plates, PS, with Immulon™ 2 HB surface
Clear plates with excellent optical quality and round well bottom.
U96 MicroWell™ Plates, PS, non-treated
Clear plates with excellent optical quality and round well bottom.

U96 MicroWell™ Plates, PS, with MaxiSorp™ surface
Clear plates with excellent optical quality and round well bottom.MaxiSorp™ suitable for solid phase immuno assays. MaxiSorp™ is hydrophilic and ideal for antibody sandwich assays.
U96 MicroWell™ Plates, PS, with Nunclon™D surface
Clear plates with excellent optical quality and round well bottom.Nunclon™Δ surface optimized for cell based assays and sterile non-treated versions for bacteriological applications. Certified.

U96 MicroWell™ Plates, PS, with PolySorp™ surface
Clear plates with excellent optical quality and round well bottom.PolySorp™ suitable for solid phase immuno assays. PolySorp™ serve to absorb hydrophobic molecules.

U96/V96 MicroWell™ Plates, PP
V-shape provides optimal recovery of reagentsShared wall technology increases well volume and wider cells improve mixingIdeal as collection plate for Nunc Filter PlatesLow binding for homogeneous assays and storage

Ultra-Micro dialysers QuikPrep® Ultra-Micro DispoDialyzer
Disposable dialyser for processing extremely small samples from 1 to 5 µl. Dialysis is performed in a microcentrifuge tube. Each Ultra-micro dialyser includes two 1.5 ml microcentrifuge collection tubes with lids. After dialysis, the sample can either be removed with a pipette or the dialyser can be inserted into a new microcentrifuge collection tube and briefly centrifuged (500 to 2000 rpm for 1 to 2 seconds). Ideal for buffer exchange, detergent removal, sample concentration for HPLC/HPCE, and purification of proteins, DNA and RNA.Easy handlingLow protein bindingHigh sample recoveryRapid dialysis/purification