
Safe-Lock Tubes® BioBased, PP, PCR clean
Made from 2nd generation recycled raw materials (e.g. recycled food oil wastes). The hinged Safe-Lock lid prevents unintentional opening. The lid seal ensures minimal evaporation rates during long-term storage and the frosted lid surfaces and jar sides enable easy and durable labelling.Pyrogen-, Dnase-, Rnase-, DNA-freeAutoclavable when open (121 °C, 20 min)ISCC PLUS and ACT certification

Safe-lock Tubes®, PP, with 2D SafeCode
Eppendorf Tubes® with two-level coding (clear coding, 2D datamatrix code) for safe sample identification. Code reading is possible even up to 25 % damaged code. Data processing software is optionally available.PCR cleanWith snap capHigh chemical and physical resistancePre-coded for immediate useDesigned and manufactured under ISO 13485 and ISO 9001
Safety bottles for safety suction system EcoVac, PP
Replacement bottles made of PP for collecting the aspirated supernatant liquid from dishes, test plates, or tubes.AutoclavableBreakproof and chemical-resistantIncl. screw cap with 2 self-locking fittingsSupplied without house couplings. House couplings available on request.

Safety bunsen burner Flame 100 set
Scope of supply: Safety bunsen burner Flame 100, gas safety adapter 470

Safety Bunsen Burner, schuett phoenix II
For sterilising, heating, flame sterilising. For use in every microbiological laboratory or in safety cabinets. Modern Bunsen burner with state-of-the-art safety features plus outstanding quality characteristics:Controlled burning time 1 sec to 120 min (selectable)Automatic safety shut-off (selectable)Overheating protection / burner control by sensorsPrecise economic flame regulation (stable flame in strong air current)Flame and ignition monitoring"Push-and-Twist" bayonet fixture for burner head, no tools needed for cleaningTilting right or leftOperating status, safety notes and warnings pictures and full text (color display) written language for most international languages. Brilliant colour display. Unique Joy-Stick navigation. Operating modes: by hand or with foot pedal or motion sensor. Housing made of stainless steel and safety glass. UV- and solvent resistant. For case of cleaning and flame-sterilising. Suitable for use with natural gas (central gas) or butane/propane gas (gas cartridges). Integrated stand for tilting right or left. Safety standard acc. to DIN 30665 part 1, DIN-DVGWschuett phoenix II eco: (with LED control lamp and foot-switch) Start flame by foot-switch or button (On/Off). Best suited for use in microbiological safety cabinets. Best price to performance ratio.schuett phoenix II standard: (brilliant colour display, selection of native language, sensor and foot- switch) Start/Stop flame by activating sensor 1x or 2x, use foot switch or press button by hand. Continuous display of timer.schuett phoenix II accu: (brilliant colour display, selection of native language, sensor and built-in extra heavy duty power cells) Start/stop flame by activating sensor 1x or 2x, use foot-switch or press button by hand. Continuous display of timer and battery power. Operates for up to 30 hours, intermittent use. Complete with battery charger for 3 hour recharging. Ideal for mobile usage.Flame sterilization carousels semi- and fully automated: For precise and time-controlled flaming of different kinds of inoculating loops. Minimization of gas consumption, the life of the inoculating loops is significantly increased. The inoculating loop is placed into the carousel after use and is sterilized immediately after turning the holder in flaming position. Sterilization time infinitely adjustable. Designed for continuous work-flow with sample series in the Laminar Flow.Semi-automated: schuett easyloop (for 6 Inoculating loop holders, included): Comfortable manual rotation,fully automated flaming process. For use with Safety Bunsen Burners schuett phoenix II standard and accu.Sterilization time: 3 to 5 s (adjustable from 1 s to 120 min)Fully automated: schuett flammy R (for 5 Inoculating loop holders, included): Fully automated rotation and inoculating. In combination with a standard gas-safety-burner (e.g. schuett phoenix II). Sterilization time: 2 to 10 s*incl. foot switch, stainless steel

Safety Bunsen Burners Flame100
The safe alternative for all traditional Bunsen or alcohol burners.Multi-Use: The Flame100 is ideally suited for all flame related applications in the laboratory. The precision flame allows graduated heating of dental tools as well as safe sterilization of microbiological instruments. Flame size and intensity can be adjusted infinitely.Easy operation: The safety Bunsen burner Flame100 activates immediately with the push of a button. No match or a pilot flame are required. Optionally, the Flame100 can also be operated by a foot pedal or an external infrared motion sensor. The Flame100 is suitable for stationary natural gas and propane / butane gas supplies as well as gas cartridges or gas cylinders. Numerous adapter systems are optionally available.Reliable safety: The proven Safety Control System (SCS) is also incorporated in the Flame100. All potential hazards are constantly monitored and, if necessary, protective measures, such as shutting off the gas supply, are activated. In addition to the ignition and flame control function and the overheating protection the safety package also features the continuous burner head control BHC. BHC unfailingly identifies burner head clogging by liquids or solid substances. Approved by DIN-DVGW, approval no. NG2211AS0167. 2 years warranty.
Safety filter for safety suction system EcoVac, PTFE
Safety filter with PP housing and PTFE membrane. For filtration of the aspirated supernatant liquid. The safety filter between the collection bottle and the pump prevents contamination and premature wear of the vacuum pump.

Safety Laboratory Gas Burners Fuego SCS series
Suitable for all flame related applications in the laboratory. The low profile body facilitates ergonomic operation; the streamlined design reduces air flow disturbances in a Cleanroom workbench. The Fuego SCS series can be operated with foot pedal, button function or touch free lR-Sensor. Made of stainless steel, with fireproof controls.SCS Safety Control System with gas safety cut off: lgnition and flame control, temperature monitor, automatic unit switch off, residual heat display, burner head assembly monitor.BHC Burner Head Control.Removable burner head.Tilt mechanism right / left.Turbo flame.Holding device for 3 inoculation loop holders.Operation with stationary natural gas and propane/butane gas supplies, cartridge gas or gas cylinders.Approved by DIN-DVGW, approval no. NG2211AS0167.Warranty: 2 years.Fuego SCS basic / Fuego SCS basic RF: With stainless steel foot pedal. The foot pedal regulates the burning time either by continuous foot pressure or by start-stop function. Instrument with ON/OFF button function. Basic model without lR-Sensor and without graphic display.Fuego SCS basic RF: Features as Fuego SCS basic but enables wireless operation due to modern radio foot pedal.Fuego SCS / Fuego SCS pro: with Double-Click lR-sensor, button function and foot pedal operation. (foot pedal optional). Double-Click IR-sensor: This adjustable safety function ensures that the burner can only be ignited by activating the lR-Sensor twice. Adjustable lR-sensor reaction distance: 5mm to 50mm.Illuminated graphic display: The animated, self-explanatory and language-less symbol display facilitates a rapid selection of all functions. 6 standard-programs with count down display: 1sec to 2hrs selectable.The first safety laboratory gas burner with comfort package: Cooling time reminder for inoculation loops, temperature regulation for heating media, gas consumption display for gas cartridges, flexible and individual by selecting user account, acoustic signals as operating aids.Additional safety assistance: Zero-pressure shut off for a pressureless gas hose. Graphical installation instructions facilitate the initial start-up.Fuego SCS pro: Features as Fuego SCS, plus battery operation (9hrs), 2 rechargeable batteries (Mignon AA), fast charge function (3hrs) and safety tilt sensor.Additional accessories are available on request.SpecificationsDimensions (W x D x H): Power supply: Weight: 103 x 130 x 49mm 100-240V 50/60Hz, max. 0,3A; 9 V DC, 1,3 A 700g

Safety Laboratory Gas Burners gasprofi 1 SCS micro
Safe gas burner for sterilizing, heating and other flame related applications. In the event of unforeseen extinction, the flame is automatically re-ignited. If the flame extincts and does not re-ignite, the burner automatically closes the gas supply.Safety Control System (SCS) with ignition and flame control function and over temperature protectionAll outer components made of stainless steelDismountable burner headSpace-savingLow working heightOperation with stationary natural gas and propane / butane gas supplies, cartridge gas or gas cylindersEnergy savingTilt adjustmentApproved by DIN-DVGW, approval no. NG2211AS10672 years guaranteegasprofi 1 SCS micro school editionOptimal safety in schoolsButton function2 standard programs for button (function knob) and foot pedalOptional operation via foot pedal or external DoubleClick IR sensorgasprofi 1 SCS microOptimal in clean room workstations and in laboratoriesDoubleClick IR sensor, button function and stainless steel foot pedal5 standard programs for IR sensor, button (function knob) and foot pedalIR sensor with adjustable operating distanceBurner head control (BHC) and residual heat indicatorHolding device for 3 inoculation loop holdersSpecificationsDimensions (W x D x H):85 x 86 x 49 mmWeight:700 gPower supply:100-240 V, 50/60Hz, max. 0,3 A / 9 V DC, 1,3 A

Safety suction system EcoVac
For safe and comfortable aspiration of liquid supernatants in cell culture. Increases work safety when handling with infectious material. Self-locking fittings close the bottle automatically and seal it hermetically for transport.Completely autoclavableBreakproof and chemical-resistant safety bottleSafety filter between bottle and pump prevents contamination and premature wearA commercial Pasteur pipette is used for aspiration (available separately)Please order optional vacuum pump separately.Replacement covers and other spare parts on request.Scope of supply: Safety suction system, safety bottle with screw cap and 2 self- locking fittings, silicone tubing 2 x 1.5 m (autoclavable), safety filter, 2 house couplings for tubing connection, 1 aeration insert
Safety suction systems AA, AC and AZ series
The DITABIS Aspiration Systems are made for the controlled aspiration of liquids from typical lab containers like cuvettes, tubes, microplates, petri dishes or roller bottles. They are also suited for the disposal of liquid biological or chemical waste and filtration of liquids by means of filter systems.Membrane vacuum pump2L or 4L bottle incl. fast lock clutches, filter, ventilation insert and 3M silicone hoseFeatures AA series:Membrane vacuum pump turns on and off automaticallyAA 02/04 with 1 handleAA 24 with 4L bottle, 2 handles and Y connectorEnlarge the automatic suction system by adding up to 4 working places and reduce your expenses for each user.Features AC series:Membrane pump with manual switch-off2L or 4L bottleFeatures AZ series:Small membrane vacuum pump2L or 4L bottleBottle holder optional*Pump dimensions
Safety suction systems AE and AK series
The DITABIS Aspiration Systems are made for the controlled aspiration of liquids from typical lab containers like cuvetts, tubes, microplates, petri dishes or roller bottles. They are also suited for the disposal of liquid biological or chemical waste and filtration of liquids by means of filter systems.Suction systems for vacuum connection in the laboratorySupplied with:2L or 4L bottle incl. fast lock clutches, filter, ventilation insert and 3M silicone hoseAK 02/04 with bottle holder and handle

Sample and diafiltration reservoir
Sample and diafiltration reservoir for Vivaflow® systems. For easy application of samples and the continuous replacement of buffer.

Sample Concentrators SC-200
A sample concentrator is a fast and convenient way of concentrating multiple samples in a block heater at once. Utilising a simple gas delivery system the sample concentrator passes an inert gas over the surface of the samples via stainless steel needles. This in combination with the heat from the block heater below produces ideal conditions for fast, efficient evaporation.Light and compactSuitable for convenient use in fume hoodsGas reservoir located on adjustable stand for accurate height controlNeedles available with 76 and 127 mm lengthNeedles available with PTFE-coating for corrosive solutionsCompatible with Dri-Block® heaters and insertsScope of delivery: Gas reservoir and stand.Please order Dry block, gas chamber sealing pad, inserts and needles separately.

Scalpel blades, non-sterile
For scalpel handles using the BAYHA interlocking system.Sterile scalpel blades are available on request, except type S01and 18R.*Special scalpel blade acuate

Scalpel Blades, sterile
For scalpel handles using the BAYHA interlocking system. Individually sterile packed in special medical foil.*Special scalpel blade acuate

Scalpel handles, stainless steel
For interchangeable, disposable blades using the BAYHA interlocking system. Blades insert into the side of the handle. Scalpel handle (Cat. No. 9.409 846) and protective sheath (Cat. No. 9.409 850) not suitable for sterile processing.

Scalpel, stainless
With wooden handle or stainless steel handle. Length 150 mm.

schuett count Colony Counter
Designed for reliable and efficient counting of bacterial colonies and bacteriophage plaques growing on nutrient agar or nutrient discs/filter disks in Petri dishes. Provides ergonomic and relaxed working.For Petri dishes with Ø 90 mm (Ø 60 or 150 mm optional)Individually adjustable lighting, pressure sensitivity of the counter plate and volumeLED lighting technology, absolutely glarefree and gentle on the eyesThree types of illumination: from below, from the side and incident light (optional)High colony transparency and differentiation (agar or nutrient discs/filter), even with transparent coloniesNo heating of the samplesNatural colour reproductionEasy counting by marking the colonies (with any felt pen) on the Petri dishAcoustic counter control (with volume control)4-digit LED-display (0 - 9999), clearly arranged foil keypadAverage count calculation, data transfer via USB to PC. Imported in Excel, for further processing, storage and printingScope of supply: For 90 mm dia. Petri dishes: adapter (transparent) for illumination from below, adapter (black/white) for illumination from side, contrast disc (black), USB-cable, marker-pen with holder.For enumeration of more than 50 Petri dishes per day, we recommend: schuett colonyQuant automatic colony counter (sample chamber, PC / laptop, software-license): The schuett colonyQuant is equipped with a high-resolution auto focus / auto-zoom colour camera. Evaluation of Petri dishes with agar Petri film, filters or nutrient pads, spiral plating or Hemmhof analysis. Storage of counting methods, documentation of results.Suitable for automatic counting and documentation of Petri dishes or nutrient pads, covered with smallest colonies (min. 0.05 mm diameter), mixed cultures. Connection to existing LIM system possible. Test evaluation of customer-specific plates in the customer's own laboratory possible before purchase.SpecificationsDimension (W x D x H):260 x 250 x 130 mmHeight with integral support stand:300 mmWeight:ca. 1.5 kg

Scrapers, L-shaped, PS
Sterile, for bacteriology applications, with 100° angling for easier use. Especially handy for dispersing liquids across agar culture plates.


Screw caps, aluminium
For test tubes, culture tubes and culture bottles.Autoclavable/ sterilisableComplete with rubber gasket
Screw caps, plastic
For test tubes, culture tubes and culture bottles.Steam-autoclavable with 121 °C/ sterilisableComplete with rubber gasket