Gel electrophoresis tank proPAGE 4, gel thickness 1.5 mm
Vertical chamber system for protein analysis in up to four hand or pre-cast gels. A maximum of 15 samples can be analysed per gel. Ideal for performing polyacrylamide gel electrophoresis (PAGE). The intuitive plate sealing system makes set-up quick and easy. High-quality moulded parts prevent leaks and ensure a long lifetime of the system. Glass plates with bonded spacers prevent gel leakage during casting and allow accurrate alignment of the gel edges. Combs with side teeth prevent slipping when casting the gel.Set for a gel thickness of 1.5 mm.Scope of supply: Buffer tank, lid, 2 x running module, power cables, 5 x glass plate with spacer (1.5 mm), 10 x short glass plate, dummy plate, 5 x comb with 10 teeth (1.5 mm), 5 x comb with 15 teeth (1.5 mm), 4 x casting base, 4 x casting frame with clamps, glass plate separator, sample loading guide

Gel electrophoresis tank VS20 Wave Maxi
Designed to perform a variety of separations, including first- and second-dimension SDS-PAGE, native, preparative, gradient and high-resolution nucleic acid electrophoresis, plus capillary tube gel IEF and electroblotting, the VS20 WAVE is one of the most versatile maxi vertical systems available.By introducing innovative, new vertical screw-clamp technology only four screws are now necessary to secure as many 20 x 20 cm gels. This gives the VS20 WAVE Maxi the selective advantage of a much faster set up speed compared to competitor products whose traditional clamping configurations require as many as 24 screws to secure just two glass plates. In addition, the WAVE's vertical screw-clamp configuration distributes pressure evenly along the height of the gel rather than in the centre to eliminate plate bowing and gel compression, but still maintains a leak-proof seal during casting; while the ergonomic wave-like design aids both handling and set up.Whatever your requirements are the WAVE can be made to meet them. Regardless of whether it is running 2 or 4 gels, electroblotting, and IEF using capillary tube gels or IPG strips, all of these techniques may be performed using the same omni-purpose unit while retaining the benefits of large format electrophoresis, such as extended separation distances, greater sample throughput and superior resolution.VS20WAVESYS incl. VS20 WAVE Maxi, Glass plates, 2 x 24 well combs, cooling coil, casting base.VS20WAVESYS-CU incl. VS20 WAVE Maxi, 20 x 20 cm Dual, 2 sets of Glass Plates, 1 mm thick bonded spacers, 2 x 24 sample, 1 mm thick combs, cooling coil, dummy plate, caster, external casting upstand.VS20CBS incl. WAVE Maxi Vertical Unit, 2 x 4 mm thick notched glass plates, 2 x 4 mm thick plain glass plates with 1 mm thick bonded spacers, 1 x dummy plate, 2 x combs (1 mm thick 24 samples), 1 x casting base, silicone mat, cooling pack.plus: 1x WAVE Standard Electroblotting Module which includes: WAVE Maxi Platinum Wire Blotting Insert, 4 x compression cassettes and 18x fibre pads.SpecificationsGel dimensions (W x L): Gel dimensions (W x L) VS20CBS:20 x 20 cm 17.5 x 18 cmUnit dimensions (W x D x H):30 x 18 x 27 cmMax. sample capacity:2 x 48 samplesBuffer volume: Buffer volume VS20CBS:min. 4.8 l (4 gels), max. 5.3 l (2 gels) min. 5.3 l, max. 6.4 l

Gel/PCR DNA Fragment Extraction Kit
The test kit was developed to obtain or concentrate DNA fragments from agarose gels, PCR or other enzymatic processes.The agarose gel is dissolved, the enzymes are denatured and the DNA fragments will bind to the glass fibre matrix in the spin column. Wash buffers (containing ethanol) are used to remove contaminants and a low salt elution buffer is used to recover the purified DNA fragments. Recoveries are 90 - 95 % for PCR clean-up. With this kit, PCR purification and gel extraction procedures can be performed, so that a second test kit is not necessary.High recovery rateShort process timeOne test kit for two methodsSpecificationsSample size:up to 300 mg of agarose gel / up to 100 µl of PCR productBinding capacity:10 µg DNAFragment size:10 kbTypical yield:80-90% gel extraction / 90-95% PCR clean-upOperation Time:20 min.


General Purpose Homogenisers, Borosilicate glass
Precision Bore Borosilicate glass mortars with a range from 5.0 to 55ml capacityBorosilicate glass pestleAll parts are fully autoclavableGrinding Clearance Pestle and Mortar: 0.152 to 0.254mm

Glass caps, DURAN®
Glass Type I / neutral glass as per USP, EP and JP. Autoclavable.

Glass mortar for dounce homogenizers
Suitable if the nuclei are to be maintained after homogenising.
Glass Plates Gelco®
Suitable for BIO-RAD™ Mini-PROTEAN™ III and Tetra Cell.Pack of 5 plates.

Graduated pipettes for tissue culture, clear glass, amber stain graduation
EX (TD) calibrated. Short form. Main point ring graduation. Specially for tissue culture and working on cleanroom benches. With durable amber stain graduation. Zero to the tip, cotton plugged (8mm outer diameter). With mouth piece for cotton plug.

Graduated Pipettes, PS, Sterile
Disposable pipettes, individual sterile packaging, pyrogen-free, clear and graduated. With colour marking and cotton wool filter.

Hand tally counter
Use for counting blood cells, bacterial colonies, drops of liquid, or any repetitive event. Tallies up to 9999. Features a quick-reset knob, lens window for easy reading, and finger ring for a secure grip. Sturdy, chrome-finished, metal housing.Dimensions: 46mm diameter x 41mm W.



Hanging bars with hooks for safety cabinets SafeFAST Premium and CytoFAST
Hanging bar made of stainless steel with 6 hooks offers the possibility to hang and store IV bags.

Heat sealing films, aluminium
The films provide very good protection against evaporation and contamination due to the tight seal.For PP and PS platesSolvent-resistantFree of DNase, RNase, DNA
Heat sealing films, aluminium
Good pierceabilityDMSO-resistantNumbers indicate the upper side of the filmSealing temperature 160 to 180 °C, 2 to 3 sFor plate types: PS, PP
Heat sealing films, PE
The films provide very good protection against evaporation and contamination due to the tight seal. The transparent PE films are used for PP sheets. Due to their good optical properties, they are suitable for qPCR and colorimetric assays. DNase, RNase, DNA free.
Heat sealing films, PET
Optically clearPeelableNumbers indicate the top side of the filmSealing temperature 160 to 185 °C, 2 to 3 s
HEPA filter replacement for cytostatic safety cabinets CytoFAST
Replacement of the HEPA filter under the work surface with an activated charcoal filter (factory fitted).


Hiflow vacuum aspirator system with pump
For vacuum aspiration of liquids, including tissue culture media, supernatants, and chemical wastes.No external vacuum system requiredBuilt-in, maintenance free pump quickly and conveniently aspirates fluidsWith quick disconnects to allow easy removal, emptying and replacement of the bottleHeavy walled collection bottle made of chemical and corrosion-resistant polypropylenePump housing made of polypropyleneLid with safety release vent to prevent vacuum implosionReplaceable hydrophobic filter protects the pump motor from fluid contaminationCollection bottle, lid, tubing and connectors are autoclavable at 121°CSpecificationsVolume collection bottle:3.8 lDimensions (W x D x H):232 x 171 x 438 mmPower supply:90 ... 240 V, 50/60 Hz