
Laboratory vacuum pump
Constant flow rates and a defined maximum vacuum guarantee consistent and reliable filtration.


LLG-Filter crucibles, porcelain
Glazed. With porous bottom. According to DIN 12909. Temperature resistant up to 900 °C.

LLG-Filter flasks with nozzle, borosilicate glass 3.3
Filter flask with side-arm made of glass. With heavy wall for vacuum apllications.Erlenmeyer shapeWhite graduation and inscription

LLG-Filtering apparatus, borosilicate glass
Universally applicable filtration unit made of high-quality borosilicate glass. Wide range of applications for filtration with filter paper or membrane filters (47 mm).Large funnel (300 ml) with scaleFilter flask 1 or 2 litres, with scaleSafe plastic oliveFilter plate with porosity 2Filter plates with porosity 1 or 3 optionally availableAll components available as spare partsScope of supply: Filter flask NS 45/40, funnel 300 ml, filter holder NS 45/40 with connector GL 14 and filter plate 47 mm (por. 2), clamp

Manifolds for Microsart® funnels and filters
For microbiological quality control. Quick connectors at both sides of the manifolds enable fast connections of either tubing, another manifold or end caps. Various funnel and filtration units are available.Full autoclavability without disassemblySterile ventingReduced risk of secondary contaminationLow working heightRubber feets providing better stability at the workplaceScope of supply: Manifold, filter base support with sinter frit, blind coupling, 20 cm tubing and venting filter

Manifolds Microsart®, for Biosart® 100 monitors
For microbiological quality control. Quick connectors at both sides of the manifolds enable fast connections of either tubing, another manifold or end caps. Various funnel and filtration units are available.Full autoclavability without disassemblySterile ventingReduced risk of secondary contaminationLow working heightRubber feets providing better stability at the workplaceScope of supply: Manifold, filter base support with sinter frit, Biosart® adapter, blind coupling, 20 cm tubing and venting filter

Manifolds Microsart®, for Biosart® 250 funnels
For microbiological quality control. Quick connectors at both sides of the manifolds enable fast connections of either tubing, another manifold or end caps. Various funnel and filtration units are available.Full autoclavability without disassemblySterile ventingReduced risk of secondary contaminationLow working heightRubber feets providing better stability at the workplaceScope of supply: Manifold, filter base support with sintered frit for 47 and 50 mm membrane filters, blind coupling, 20 cm tubing and plug for venting holes

Manifolds Microsart®, including stainless steel funnels
For microbiological quality control. Quick connectors at both sides of the manifolds enable fast connections of either tubing, another manifold or end caps. Various funnel and filtration units are available.Full autoclavability without disassemblySterile ventingReduced risk of secondary contaminationLow working heightRubber feets providing better stability at the workplaceScope of supply: Manifold, filter base support with sintered frit for 47 and 50 mm membrane filters, blind coupling, 20 cm tubing and plug for venting holesDimensions without funnels and tubing

Pressure filter holder, stainless steel
For 47mm diameter membrane filters. With reservoir barrel allowing up to 200ml of liquid to be filtered by connection to a suitable direct pressure source. Can also be used for filtering larger volumes in conjunction with a 5L pressurising container. Complete with silicone O-rings and 10mm diameter tubing ferrules on the inlet and outlets. For sterile filtration of tissue cultures, ultrafiltration of buffer solutions, cell count solutions and for pressing soil samples.

Pressure filter holder, stainless steel
For 142 mm diameter membrane filters. With large capacity barrel allowing up to 2 litres of liquid to be filtered by connection to a suitable direct pressure source. For preparing sludge or separating suspended matter from waste water samples, or sterile filtration of liquids that are difficult to filter, e.g. serum. Filtration surface area: 130 cm². Maximum pressure 7 bar. The holder is supplied complete with a back pressure screen.

Pressure filtration units Sartolab® P20
Pressure filter unit for the sterile filtration of media and aqueous solutions. The filters are individually packed and sterilized by ethylene oxide (EO).

Pressure filtration units Sartolab® P20 plus
Pressure filter unit with prefilter for clarification or prefiltration of particle-high-loaded solutions.

Pressure filtration units Sartolab® P20 plus, with filling bell
Pressure filtration unit for sterile filtration or clarification of media, aqueous solutions and solvent mixtures in batches.Prefilter: High purity binder-free quartz microfibersOutlet: Hose barb with filling bell and lid

Rubber sleeves
For filter crucibles. Temperature resistant up to 150 °C. Autoclavable.


Rubber Spacers (GuKo), natural rubber
Rubber Spacers, made of natural rubber (NR). Conical, to fit filter funnels or crucibles into suction flasks. Durometer 40 Shore A
Set Funnels Microfil® and membrane filters EZ-Pak
For general microbiological analysis. The set includes Microfil® funnels made of PP and membrane filters EZ-Pak made of mixed cellulose ester.SterileMembrane filters griddedScope of suply: 150 funnels, 150 membrane filters

Set of rubber spacers (GuKo), natural rubber
Comprises of 5, 7 or 8 Gukos with an external lower diameter of 12 mm, 17 mm, 21 mm, 27.5 mm, 33 mm, 48 mm, 58 mm and 66 mm each. Hardness 40 Shore A.

Slotted sieve disc (perforated plate) DURAN®
Can be used in the 250ml capacity dismountable filter holder as a carrier for membrane and paper filters.

Slotted sieve filter funnels (Buchner funnels), DURAN®
Buchner pattern funnel with slotted sieve (perforated) filter plate. Glass Type I / neutral glass as per USP, EP and JP. Autoclavable.
Stainless steel filter manifold system
Combisart® Multibranch System with modular structure: For microbiological analysis. Basic system without outlet for holding all dismountable Sartorius vacuum funnels either completely or by using appropriate adapters.

Vacuum Adapter GL, PTFE
For safe assembly of standard filter funnels made of glass or plastic on laboratory bottles. With lateral 2-step hose connector for connection to a vacuum pump. Pass-through with O-ring made of FKM. FDA conform. Chemikally resistant. Autoclavable.

Vacuum Adapter NS, PTFE
For safe assembly of standard filter funnels made of glass or plastic on laboratory bottles. With lateral 2-step hose connector for connection to a vacuum pump. Pass-through with O-ring made of FKM. FDA conform. Chemikally resistant. Autoclavable.Pass-through with O-ring made of FKM for safe assembly of standard filter funnels on vessels with ground joint. Lateral 2-step hose connector made of PTFE for connection to a vacuum pump.