Climate Chambers ICH C, with humidity and CO2 control
The climate chamber generation with the unique ControlCOCKPIT for a quick and intuitive operation. Unparalleled temperature and humidity homogeneity for long-term stable ambient conditions.PID microprocessor control with integrated auto-diagnostic systemInterior stainless steel 1.4301 (ASTM 304), deep-drawnStructured stainless steel housing, rear of zinc-plated steelHigh-Operation and adjustment of all parameters directly at the ControlCOCKPIT temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standardsInternal data logger with a storage capacity of at least 10 yearsGerman, English, French, Spanish language settings available on the ControlCOCKPITDigital backwards counter with target time setting adjustable between 1 minute and 99 daysThe SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamberAdjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT, for example relative humidityMoisture tight standard entry port, at the back, 40 mm inner diameter, can be closed by silicone stopperTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysAvailable parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), programme time, relative humidity, time zones, summertime/wintertimeTwo Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an errorAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB portControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID functionDisplaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week)Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online loggingMultiple overtemperature protection: Electronic temperature monitoring TWW/TWB (protection class 3.3 or 2 and mechanical temperature limiter TB (protection class 1) acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN/MAX values for over/undertemperature alarmThe climate chamber generation with the unique ControlCOCKPIT for a quick and intuitive operation. Unparalleled temperature and humidity homogeneity for long-term stable ambient conditions.PID microprocessor control with integrated auto-diagnostic systemInterior stainless steel 1.4301 (ASTM 304), deep-drawnStructured stainless steel housing, rear of zinc-plated steelHigh-Operation and adjustment of all parameters directly at the ControlCOCKPIT temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standardsInternal data logger with a storage capacity of at least 10 yearsGerman, English, French, Spanish language settings available on the ControlCOCKPITDigital backwards counter with target time setting adjustable between 1 minute and 99 daysThe SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamberAdjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT, for example relative humidityMoisture tight standard entry port, at the back, 40 mm inner diameter, can be closed by silicone stopperTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysAvailable parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), programme time, relative humidity, time zones, summertime/wintertimeTwo Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an errorAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB portControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID functionDisplaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week)Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online loggingMultiple overtemperature protection: Electronic temperature monitoring TWW/TWB (protection class 3.3 or 2 and mechanical temperature limiter TB (protection class 1) acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN/MAX values for over/undertemperature alarm
Climate Chambers ICH L, with humidity control and light
The climate chamber generation with the unique ControlCOCKPIT for a quick and intuitive operation. Unparalleled temperature and humidity homogeneity for long-term stable ambient conditions.PID microprocessor control with integrated auto-diagnostic systemInterior stainless steel 1.4301 (ASTM 304), deep-drawnStructured stainless steel housing, rear of zinc-plated steelHigh-Operation and adjustment of all parameters directly at the ControlCOCKPIT temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standardsInternal data logger with a storage capacity of at least 10 yearsGerman, English, French, Spanish language settings available on the ControlCOCKPITDigital backwards counter with target time setting adjustable between 1 minute and 99 daysThe SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamberAdjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT, for example relative humidityMoisture tight standard entry port, at the back, 40 mm inner diameter, can be closed by silicone stopperTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysAvailable parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), programme time, relative humidity, time zones, summertime/wintertimeTwo Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an errorAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB portControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID functionDisplaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week)Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online loggingMultiple overtemperature protection: Electronic temperature monitoring TWW/TWB (protection class 3.3 or 2 and mechanical temperature limiter TB (protection class 1) acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN/MAX values for over/undertemperature alarmSpecially designed for testing pharmaceutical products according to ICH, Q1A and Q1B, option 2, and similar global standards for stability tests of cosmetics and food.

Climate Chambers ICH, with humidity control
The climate chamber generation with the unique ControlCOCKPIT for a quick and intuitive operation. Unparalleled temperature and humidity homogeneity for long-term stable ambient conditions.PID microprocessor control with integrated auto-diagnostic systemInterior stainless steel 1.4301 (ASTM 304), deep-drawnStructured stainless steel housing, rear of zinc-plated steelHigh-Operation and adjustment of all parameters directly at the ControlCOCKPIT temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standardsInternal data logger with a storage capacity of at least 10 yearsGerman, English, French, Spanish language settings available on the ControlCOCKPITDigital backwards counter with target time setting adjustable between 1 minute and 99 daysThe SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamberAdjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT, for example relative humidityMoisture tight standard entry port, at the back, 40 mm inner diameter, can be closed by silicone stopperTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysAvailable parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), programme time, relative humidity, time zones, summertime/wintertimeTwo Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an errorAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB portControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID functionDisplaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week)Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online loggingMultiple overtemperature protection: Electronic temperature monitoring TWW/TWB (protection class 3.3 or 2 and mechanical temperature limiter TB (protection class 1) acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN/MAX values for over/undertemperature alarmThe climate chamber generation with the unique ControlCOCKPIT for a quick and intuitive operation. Unparalleled temperature and humidity homogeneity for long-term stable ambient conditions.PID microprocessor control with integrated auto-diagnostic systemInterior stainless steel 1.4301 (ASTM 304), deep-drawnStructured stainless steel housing, rear of zinc-plated steelHigh-Operation and adjustment of all parameters directly at the ControlCOCKPIT temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standardsInternal data logger with a storage capacity of at least 10 yearsGerman, English, French, Spanish language settings available on the ControlCOCKPITDigital backwards counter with target time setting adjustable between 1 minute and 99 daysThe SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamberAdjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT, for example relative humidityMoisture tight standard entry port, at the back, 40 mm inner diameter, can be closed by silicone stopperTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysAvailable parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), programme time, relative humidity, time zones, summertime/wintertimeTwo Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an errorAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB portControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID functionDisplaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week)Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online loggingMultiple overtemperature protection: Electronic temperature monitoring TWW/TWB (protection class 3.3 or 2 and mechanical temperature limiter TB (protection class 1) acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN/MAX values for over/undertemperature alarm

Climatic Test Chamber CTC256
Simulate the perfect atmosphere for climate and temperature tests, specifically in accordance with DIN EN 60068-2-1, 2-2 and 2-3. Provide unlimited flexibility for controlled material and function tests as well as ageing tests.Ventilation and Control: high-performance air fan in working chamberdepending on operation status automatically variable fan speed with manual adjustment from 10 % to 100 %adaptive, fuzzy-supported multifunctional digital microprocessor PID-controllerautodiagnostic system with fault indication on temperature and humidity control2 x Class A, 4-wire circuit, Pt100 sensors, mutually monitoring and maintaining performance at the same temperature valuedigital 7-day-programme-timer with real time clock, precise minute settingintegral timer for heating profiles of up to 40 ramps, each segment adjustable from 1 min. up to 999 hoursdigital display (LED) of all set parameters, such as temperature, weekdays, time, humidity and set-up values - language to be chosen in setupdigital display of set values (resolution: 0.1 °C below 99.9 °C, 0.5 °C above 100 °C) and actual values (resolution: 0.1 °C) of temperature (LED)long-term documenting (ring store) of all relevant data, GLP-conforming as data logger - 1024 kBprogramme stored on power failureparallel printer interface (incl. real-time clock with date function) for all PCL3-compatible ink-jet printers for GLP-conforming documentationUSB interface including Memmert "Celsius" software for programming and documentationchip card control incl. one MEMoryCard XL with 32 kB (up to 40 ramps)incl. works calibration certificate for -20 °C and 160 °CHeating concept: high-performance ring heaters with optimised air circulationdoor heating to avoid condensateCooling Concept:twin compressorspeed adjustable condenser fanrefrigerant R449AMultiple Overtemperature Protection:with audible and visual alarm in case of over-/undertemperature and over-/under-humidity, open door and empty water tankindependently working, digitally adjustable electronic overtemperature controller, TWW protection class 3.3additional adjustable Auto-Safety-Function "ASF" for over- and undertemperature automatically following the set value at a preset tolerance rangemechanical temperature limiter TB class 1 switching the heating off at approx.10 °C above max. oven temperatureStandards for CTC additionally:Electronically controlled active humidification and dehumidification from 10 % to 98 % rh with digital display of the relative humidity, display resolution 0.5 %, setting accuracy 1 %incl. works calibration certificate for 30 °C at 60 % rhHumidity supply with distilled water from 2 x 10 l tanks on integrated telescopic slide, with automatic water tank change-over2 x 10 l tanks acting as condensate collectors, on telescopic slide mounts

Constant climate chamber KBF PRO
The constant climate chambers of the KBF PRO series are equipped with APT.line™ preheating chamber technology and a wide temperature and humidity range, making them suitable for all types of material testing. The humidity range is controlled by means of a capacitive humidity sensor and responsive steam humidification. The constant climate chambers are equipped with proven compressor technology to ensure reliable and failsafe long-term operation. Thanks to the modern inverter cooling unit and the climate-neutral refrigerant R-290, energy-efficient and environmentally friendly cooling is guaranteed. The inner chamber and the two racks with telescopic rails are made of stainless steel, while the inner doors are made of metal oxide-coated safety glass.Adjustable fan speedDoor heating to prevent condensationIntuitive touchscreen controller with time-segment and real-time programmingErgonomically adjustable control terminal (for models from 470 l volume)Signal triangle with light-up status display (for models with a volume of 470 l or more) Internal data logger, measured values can be read out in open format via USB interfaceEthernet interfaceBINDER Multi Management Software APT-COM™ Basic EditionDevice self-test for comprehensive status analysisClass 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarmTable-top device KBF PRO 130 is stackableFloor-standing devices with robust twin casters with brakes at the frontModels 260, 470 and 720 can be optionally equipped with light modules for ICH photostability tests. With optional LED light modules, the KBF PRO models from 260 upwards become a plant growth cabinet. Please order light modules separately.

Constant climate chamber KBF, white
The constant climate chambers of the KBF series are equipped with APT.line™ preheating chamber technology and a large temperature and humidity range. The KBF fulfills all important ICH requirements and, with its high climate homogeneity, ensures reliable ICH stability tests in the pharmaceutical industry. The humidity range is controlled by means of a capacitive humidity sensor and responsive steam humidification. The constant climate chambers are equipped with proven compressor technology to ensure reliable and failsafe long-term operation. Thanks to the modern inverter cooling unit and the climate-neutral refrigerant R-600a, energy-efficient and environmentally friendly cooling is guaranteed. The inner chamber and the two racks are made of stainless steel, while the inner doors are made of metal oxide-coated safety glass.Adjustable fan speedDoor heating to prevent condensationIntuitive touchscreen controller with time-segment and real-time programmingErgonomically adjustable control terminal (for models from 470 l volume)Signal triangle with light-up status display (for models with a volume of 470 l or more)Internal data logger, measured values can be read out in open format via USB interfaceEthernet interfaceBINDER Multi Management Software APT-COM™ Basic EditionDevice self-test for comprehensive status analysisClass 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarmTable-top device KBF 130 is stackableFloor-standing devices with robust twin casters with brakes at the frontModels 260, 470 and 720 can be optionally equipped with light modules for ICH photostability tests. With optional LED light modules, the KBF models from 260 upwards become a plant growth cabinet. Please order light modules separately.

Constant Climate Chambers HPPeco
Thanks to unbeatable energy efficiency and low-maintenance operation, the HPPeco constant climate chambers are perfectly suited for stability tests, environmental testing and materials testing. The high precision temperature control as well as the active humidification and dehumidification were particularly adapted to the ICH guidelines, option Q1A, for stability tests.LED light module for sizes 110 to 750 (as an option): dimmable LED light in three alternative colour temperatures (cold white light, warm white light or cold white and warm white light, dimmable in steps of 1 %)Heating and cooling seamlessly with one system thanks to Peltier technology. Almost vibration-free and extremely quietTwinDISPLAY: ControlCOCKPIT with two TFT colour displaysYou can find a detailed description of the "TwinDISPLAY" model at www.memmert.com

Constant climate chambers KBF-S ECO
Constant climate chambers for long-term tests and accelerated stability tests of pharmaceutical products according to the ICH guideline Q1A. Particularly energy-efficient and low-noise thanks to Peltier technology with patented heat dissipation.Homogeneous climate even with full loadElectronically controlled APT.line™ preheating chamber technologyTemperatures up to 28 °C below ambient temperature possibleInner chamber made completely of stainless steel2 stainless steel grids incl. shelf supportAccess port with silicone plug Ø 30 mm, left sideUnit self-test for comprehensive status analysisLCD display for indication of temperature, humidity, alarms and additional informationInternal data logger with USB interfaceIndependent water supply via canisters

Dynamic climate chambers MK
Environmental chambers are ideal for material testing under dynamic conditions. The standard rapid alternation speeds of approx. 5 K/min enable standard-compliant testing.Homogeneous climate conditions thanks to APT.line™ preheating chamber technologyTouchscreen controller with time-segment and real-time programmingInternal data logger, measured values can be read out via USBProgrammable condensation protectionTroubleshooting system with visual and acoustic alarmsHeated viewing window with LED interior lightingBINDER Multi Management Software APT-COM™ Basic EditionClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmEthernet interfaceAdjustable ramp functionIntegrated chart recorderDoor heatingInner chamber made of stainless steel1 stainless steel rackCFC-free refrigerant R-452AModels with 480 V nominal voltage are equipped with a voltage and frequency converter.

Dynamic climate chambers MKF, with humidity control
Environmental chambers are ideal for material testing under dynamic conditions. The standard rapid alternation speeds of approx. 5 K/min enable standard-compliant testing.Homogeneous climate conditions thanks to APT.line™ preheating chamber technologyTouchscreen controller with time-segment and real-time programmingInternal data logger, measured values can be read out via USBProgrammable condensation protectionTroubleshooting system with visual and acoustic alarmsHeated viewing window with LED interior lightingBINDER Multi Management Software APT-COM™ Basic EditionClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmEthernet interfaceAdjustable ramp functionIntegrated chart recorderDoor heatingInner chamber made of stainless steel1 stainless steel rackHumidity regulation with capacitive humidity sensor and responsive steam humidificationAutomatic water and wastewater managementIntegrated 20 l water storage tank4 zero-voltage relay contactsCFC-free refrigerant R-452AModels with 480 V nominal voltage are equipped with a voltage and frequency converter.

Dynamic climate chambers MKFT, with humidity control and extended low temperature range
Environmental chambers are ideal for material testing under dynamic conditions. The standard rapid alternation speeds of approx. 5 K/min enable standard-compliant testing.Homogeneous climate conditions thanks to APT.line™ preheating chamber technologyTouchscreen controller with time-segment and real-time programmingInternal data logger, measured values can be read out via USBProgrammable condensation protectionTroubleshooting system with visual and acoustic alarmsHeated viewing window with LED interior lightingBINDER Multi Management Software APT-COM™ Basic EditionClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmEthernet interfaceAdjustable ramp functionIntegrated chart recorderDoor heatingInner chamber made of stainless steel1 stainless steel rackHumidity regulation with capacitive humidity sensor and responsive steam humidificationAutomatic water and wastewater managementIntegrated 20 l water storage tank4 zero-voltage relay contactsCFC-free refrigerant R-452A and R-23Models with 480 V nominal voltage are equipped with a voltage and frequency converter.

Dynamic climate chambers MKT, with extended low temperature range
Environmental chambers are ideal for material testing under dynamic conditions. The standard rapid alternation speeds of approx. 5 K/min enable standard-compliant testing.Homogeneous climate conditions thanks to APT.line™ preheating chamber technologyTouchscreen controller with time-segment and real-time programmingInternal data logger, measured values can be read out via USBProgrammable condensation protectionTroubleshooting system with visual and acoustic alarmsHeated viewing window with LED interior lightingBINDER Multi Management Software APT-COM™ Basic EditionClass 2 independent adjustable temperature safety device (DIN 12880) with visual alarmEthernet interfaceAdjustable ramp functionIntegrated chart recorderDoor heatingInner chamber made of stainless steel1 stainless steel rack4 zero-voltage relay contactsCFC-free refrigerant R-452A and R-23Models with 480 V nominal voltage are equipped with a voltage and frequency converter.

Environmental chambers, stainless steel, with humidity control and light option
The units are suitable for apptications in the pharmaceutical or life science sector. Optimal incubation conditions due to temperature, light, and humidity control.Stainless steel interior and shelvesMassive doorDirected horizontal airflow systemAdjustable defrost timerOver- and under-temperature protectionRefrigerant R-513AHeight-adjustable, vertical light modules (optional)Programmable light cycles: on/off cycles for every day of the week, dawn/dusk simulationsAccess port Ø 54 mm
External water supply
Free-standing. Set consisting of fresh water canister (20 l) with pump, level sensor, and waste water canister (20 l).

Humidity Chambers HCP
The Memmert humidity chamber HCP - This climate chamber offers a full range of comfort, reliability and safety. This humidity chamber is ideally suited for environmental testing, environmental simulation, accelerated service life tests and 85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78.The active humidity control is the guarantee for ideal homogeneity of temperature and humidity as well as for short recovery times after opening the door. In combination with heating on all six sides, including heated inner glass door, it also minimises vaporisation in the interior and thus the risk of condensed water dripping onto the test object. An aluminium thermal conductive layer supports optimum temperature distribution and serves as a heat accumulator in case of a temporary power failure.Model variant TwinDISPLAY: ControlCOCKPIT with two colour displaysYou can find a detailed description of the "TwinDISPLAY" model at www.memmert.com
ICH light modules for cooling incubators KB PRO and constant climate chambers KBF/KBF PRO
ICH-Q1B light modules for ICH photostability tests.
Interior lighting for constant climate chambers KBF PRO
Interior lighting with climate-resistant LEDs, switches when the unit door is opened.
LED light bars Basic set
Basic set consisting of 2 pieces, mounting material, control unit for max. 4 light strips, 100 to 240 V, 50/60 Hz.
LED light bars Expansion set
Expansion set consisting of 2 pieces, attachment material: clips. For expanding the basic set of light bars.
Light module for plants
LED plant light module consisting of 16 LED light strips, 3-channel controller and fresh air pump, as well as an independent power supply.