Tube tests NANOCOLOR® Tin
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.

Tube tests NANOCOLOR® TOC Neo
For the determination of TOC in water samples. The screw couplings make it easier to screw the cuvettes together. They ensure that the digestion is possible in a closed system.

Tube tests NANOCOLOR® TTC / sludge activity
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.

Tube tests NANOCOLOR® Zinc
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.

Turbidity meter Eutech™ TN-100
The microprocessor-based waterproof Infra-Red Turbidity meter TN-100 is easy-to-use and meets all rigor of rugged field applications. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).IP67 Waterproof and Dustproof, easy cleaning and maintenance Automatic Push-Button Calibration (4 points) for unprecedented full-range accuracy Power-saving feature allows over 1200 measurementsLarge Easy-to-Read Display for optimum viewing of measurements with user-friendly message codes for easy troubleshooting Meets Performance Criteria as specified by ISO 7027 (DIN EN 27027) method Scope of supply: Turbidity meter with 4 calibration standards, 3 empty cuvettes, sturdy carrying case, batteries and instruction manualSpecificationsTurbidity range:0 to 2000 NTUResolution:0.01 NTU (0 to 19.9 NTU) 0.1 NTU (20.0 to 99.9 NTU) 1 NTU (100 to 2000 NTU)Accuracy:± 2 % of reading ± 1 LSD ( 0 to 500 NTU) ± 3 % of reading ± 1 LSD (501 to 2000 NTU)Repeatability:± 1 % of reading or ± 0.01 NTUCalibration Points:4 points (automatic)Response Time: 6 seconds for full step changeCalibration Standards:0.02 NTU; 20.0 NTU; 100 NTU; 800 NTULight Source:Infrared-emitting diode (850 nm)Light Source Life: 1,000,000 testsPower supply:4 x 1.4 V batteries, 200 h

Turbidity meter TB 211 IR
The compact infrared turbidity meter TB 211 IR is designed to allow fast, precise on-site testing. The unit measures the scattered light at an angle of 90°, as stipulated in EN ISO 7027. The wide measuring range from 0.01 to 1100 TE/F = NTU = FNU permits use of the unit for various media, ranging from drinking water to waste water.As infrared light is used for measurement, the unit can be used to test both coloured and colourless liquids. The standards required for calibration of the unit are also supplied. A second adjustment mode allows alternative adjustment with user-defined turbidity standards.measuring ranges from 0.01 to 1100NTU (autorange)measurement with infrared light at an angle of 90°easy operation600 tests between battery chargesScope of supply: Turbidity meter, 4 turbidity standards <0.1, 20, 200 and 800NTU, battery, USB cable (1.5 m), test vial, manual, warranty statement, caseSpecifications:Measurement cycle:approx. 9 secondsDisplay / Function:LCDOptics:temperature-compensated LED and photosensor amplifier in waterproof sample chamberKeypad: Measuring range:4 key polycarbonate membrane 0.01 to 1100NTU (autorange)Resolution:0.01 to 9.99NTU = 0.01NTU 10.0 to 99.9NTU = 0.1NTU 100 to 1100NTU = 1NTUAccuracy:±2.5 % of measuring value or ±0.01 NTU (0 to 500 NTU) ±5 % (500 to 1100NTU)Interface: Housing: Dimensions (L x W x H):Micro USB ABS 190 x 110 x 55mmWeight (Basis unit):approx. 0.4kgTemperature:0 to 40°CHumidity (rel.):30 to 90 % R.H.CE-conformity:DIN EN 50081-1, VDE 0839 part 81-1:1993-03, DIN EN 50082-2, VDE 0839 part 82-02:1996-02

Turbidity meter TB350 IR
The portable turbidity meters are characterised by the use of Multipath 90° BLAC® technology. Samples with low and high turbidity can be analyzed entirely nephelometric (Detection angle 90°) with the highest accuracy over the complete measuring range up to 4000 NTU. By eliminating stray light, highly accurate results are achieved for low turbidities down to 0.01 NTU.High performance optics to ensure accuracyElimination of stray light through light absorbing trap (BLAC®)Intuitive colour touch screen with animated guided procedures and straightforward data management, multilingualVisual warning for out-of-tolerance readingsData logger for 250 measurements plus all calibrations, verifications and factory recovery procedures3 different modes: single, signal averaging, fast settlingUSB-C interfaceOptional operation with rechargeable battery pack or mains adapterScope of supply: Instrument, carrying case with plastic insert, T-CAL® calibration and verification standards, silicone oil, sample vials with black lids, cleaning cloth, brush for sample vials, screwdriver, AA batteriesWith infra red LED light source (860 nm), acc. to ISO 7027. Incl. Turbidity standards with 5, 20, 800 and 4000 NTU.SpecificationsMeasuring range:0 ... 4000 NTUResolution:0.01 NTUAccuracy:±1.8 % + 0.014 NTUDimensions (W x D x H):155 x 225 x 83 mmWeight:898 gPower supply:4 x AA batteriesReproducibility:1 %, ±0,01 NTUIP code:IP 67

Turbidity meter TB350 WL
The portable turbidity meters are characterised by the use of Multipath 90° BLAC® technology. Samples with low and high turbidity can be analyzed entirely nephelometric (Detection angle 90°) with the highest accuracy over the complete measuring range up to 4000 NTU. By eliminating stray light, highly accurate results are achieved for low turbidities down to 0.01 NTU.High performance optics to ensure accuracyElimination of stray light through light absorbing trap (BLAC®)Intuitive colour touch screen with animated guided procedures and straightforward data management, multilingualVisual warning for out-of-tolerance readingsData logger for 250 measurements plus all calibrations, verifications and factory recovery procedures3 different modes: single, signal averaging, fast settlingUSB-C interfaceOptional operation with rechargeable battery pack or mains adapterScope of supply: Instrument, carrying case with plastic insert, T-CAL® calibration and verification standards, silicone oil, sample vials with black lids, cleaning cloth, brush for sample vials, screwdriver, AA batteriesWith white light LED light source, acc. to EPA (pending). Incl. Turbidity standards with 5, 20, 800, 2000 and 4000 NTU.SpecificationsMeasuring range:0 ... 4000 NTUResolution:0.01 NTUAccuracy:±1.8 % + 0.014 NTUDimensions (W x D x H):155 x 225 x 83 mmWeight:898 gPower supply:4 x AA batteriesReproducibility:1 %, ±0,01 NTUIP code:IP 67

Turbidity meter Turb® 430
The turbidity meters Turb® 430 IR acc. to DIN ISO 27027 and Turb® 430 T acc. to US EPA 180.1 meet the requirements of the nephelometric measurement at 90° stray light for drinking water with highest precision, especially in the range < 1 NTU. The measuring range comprises 0-1100 NTU/FNU with automatic measuring range switching and is therefore suitable for water analysis as well as quality control, such as gasoline, cell cultures, as well as in the food and beverage industries.The measurement and automatic 3-point calibration runs self-explanatory and menu-controlled. The calibration takes place via an AMCO Clear® standard set (0.02-10-1000 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata. The quality assurance of the measured results is supported by calibration interval setting with documentation.Scope of supply: Turbidity meter with calibration set 0.02-10.0-1000 NTU

Turbidity meter Turb® 430 Set
The turbidity meters Turb® 430 IR acc. to DIN ISO 27027 and Turb® 430 T acc. to US EPA 180.1 meet the requirements of the nephelometric measurement at 90° stray light for drinking water with highest precision, especially in the range < 1 NTU. The measuring range comprises 0-1100 NTU/FNU with automatic measuring range switching and is therefore suitable for water analysis as well as quality control, such as gasoline, cell cultures, as well as in the food and beverage industries.The measurement and automatic 3-point calibration runs self-explanatory and menu-controlled. The calibration takes place via an AMCO Clear® standard set (0.02-10-1000 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata. The quality assurance of the measured results is supported by calibration interval setting with documentation.Scope of supply: Turbidity meter in case with table insert, calibration set 0.02-10.0-1000 NTU, PC software LSdata, accessories

Turbidity meter Turb® 750 IR
Nephelometrical turbidity measurement according to DIN EN ISO 7027-1.High-precision turbidity measuring devices for standardized measurement in drinking water and laboratory and industrial applications with AQA-based turbidity measurement.Backlit graphic display, 160 x 104 PixelQuick response timeMultiple measurements and evaluation of the measurement data with the intelligent reproducibility and plausibility check (IRPC)Function keysComfortable menu-guided 3-point standard calibrationFlexible calibration with 2 to 5 user-defined calibration pointsQuickCAL: 1-point-calibration at 10 NTUAQA, calibration interval and records with PC-documentation and LIMS connectionFor round cells with diam. 28 mm, volume min. 15 mlWith RS 232 interface, USBMemory: 2500 data setsScope of supply: Turbidity meter, 4 x batteries, wide range power supply, cable USB-A to USB-B mini, 6 x empty vials, sticker for orientation marking, calibration kit, cloth, manuals, CD ROM with manual and PC software Turb® Data, inspection protocol

Turbidity meter Turb® 750 T
Nephelometrical turbidity measurement according to US EPA 180.1.High-precision turbidity measuring devices for standardized measurement in drinking water and laboratory and industrial applications with AQA-based turbidity measurement.Backlit graphic display, 160 x 104 PixelQuick response timeMultiple measurements and evaluation of the measurement data with the intelligent reproducibility and plausibility check (IRPC)Function keysComfortable menu-guided 3-point standard calibrationFlexible calibration with 2 to 5 user-defined calibration pointsQuickCAL: 1-point-calibration at 10 NTUAQA, calibration interval and records with PC-documentation and LIMS connectionFor round cells with diam. 28 mm, volume min. 15 mlWith RS 232 interface, USBMemory: 2500 data setsScope of supply: Turbidity meter, 4 x batteries, wide range power supply, cable USB-A to USB-B mini, 6 x empty vials, sticker for orientation marking, calibration kit, cloth, manuals, CD ROM with manual and PC software Turb® Data, inspection protocol

Turbidity Sensor VisoTurb® 900-P for Meters MultiLine® IDS
Accessories for measuring instruments MultiLine® IDS from WTW® for measuring turbidity parameters. Please order measuring instruments separately.

Turbidity Standards
Highly accurate turbidity standards composed of suspended microspheres, suitable for Instrument calibration and control of all turbidity meters. Stable, shelf life of 2 years (from Date of Manufacturing). NIST traceable, US EPA approved and tested in compliance with ISO 7027. HDPE bottles of 100 ml.Two ranges available:Ratio range for Ratio Turbidity Measuring instruments (measure of the scattered light from the sample at a 90° angle from the incident light, plus at additional angles (several detectors)Non Ratio for Non Ratio Turbidity Measuring instruments will measure the scattered light from the sample at a 90° angle from the incident light (one detector)
Turbidity Standards StablCal® Formazine
Stabilized formazine turbidity standard for use in turbidity meters.

Ultra pure water system OmniaPure xsbasic
For ultra pure water type I.Ultra pure water of the highest quality for analytical and life science applications in the laboratory. With the standard dispenser and monitoring unit OptiFillbasic, laboratory vessels can be filled conveniently and precisely. The recirculation function prevents the growth of biofilms.Compact designCan be used with deionised waterDispenser pivotable up to 170°Ergonomic, flexible dispenser and monitoring unit OptiFillbasic with graphic displayReal-time display of all operating and performance parametersSetting possibilities for conductivity in MΩ x cm or µS/cmPassword access2 languages selectable: DE, ENLeakage sensorIntegrated pressure reducerAutomatic voltage adjustmentApplications:OmniaPure xsbasic: AAS, IC, ICP, buffers and media preparationOmniaPure xsbasic UV: Ultra trace analysis, ICP-MS, HPLC, TOC analysisScope of supply: Ultra pure water system, pre-treatment cartridge, ultra pure water cartridge, sterile filter capsule (0.2 µm)Ultra pure water output:Up to 2 l/minResistivity at 25 °C:18.2 MΩ x cmConductivity at 25 °C:0.055 µS/cmBacteria (with filter):0.01 CFU/mlParticles (with filter):1/mlFeed water conductivity at 25 °C:100 µS/cmDimensions (W x D x H):240 x 435 x 530 mmWeight:14 kgPower supply:90 ... 240 V, 50 ... 60 Hz

Ultra pure water system OmniaPure xstouch
For ultra pure water type I.Ultra pure water of the highest quality for analytical and life science applications in the laboratory. With the standard control and monitoring unit OptiFilltouch, laboratory vessels can be filled conveniently and precisely. The recirculation function prevents the growth of biofilms.Compact designCan be used with deionised waterDispenser pivotable up to 170°Digital control and monitoring unit OptiFilltouch with colour touch displayReal-time TOC monitoringAdjustable limit values for conductivity and TOCInnovative monitoring and display of cartridge capacityWithdrawal volume individually adjustablePermanent data storage of all quality parametersPassword access and error memory3 languages selectable: DE, EN, FRRS232 and USB interfaceLeakage sensorIntegrated pressure reducerAutomatic voltage adjustmentCan be operated with laboratory glovesApplications:OmniaPure xstouch UV-TOC: Ultra trace analysis, ICP-MS, HPLC, TOC analysisOmniaPure xstouch UV-TOC/UF: Molecular and microbiology, cell culture mediaScope of supply: Ultra pure water system, pre-treatment cartridge, ultra pure water cartridge, sterile filter capsule (0.2 µm)Ultra pure water output:Up to 2 l/minDispensing volume:0.05 ... 25 lResistivity at 25 °C:18.2 MΩ x cmConductivity at 25 °C:0.055 µS/cmBacteria (with filter):0.01 CFU/mlParticles (with filter):1/mlRNase (with UF module):1 pg/mlDNase (with UF module):5 pg/mlProteases (with UF module):0.15 µg/lFeed water conductivity at 25 °C:100 µS/cmDimensions incl. OptiFilltouch dispenser (W x D x H):240 x 435 x 530 mmWeight incl. OptiFilltouch dispenser:14 kgPower supply:90 ... 240 V, 50 ... 60 Hz

Ultra pure water system OmniaPure xstouch, under-bench version with OptiFilltouch bench dispenser
For ultra pure water type I.Ultra pure water of the highest quality for analytical and life science applications in the laboratory. With the standard control and monitoring unit OptiFilltouch, laboratory vessels can be filled conveniently and precisely. The recirculation function prevents the growth of biofilms.Compact designCan be used with deionised waterDispenser pivotable up to 170°Digital control and monitoring unit OptiFilltouch with colour touch displayReal-time TOC monitoringAdjustable limit values for conductivity and TOCInnovative monitoring and display of cartridge capacityWithdrawal volume individually adjustablePermanent data storage of all quality parametersPassword access and error memory3 languages selectable: DE, EN, FRRS232 and USB interfaceLeakage sensorIntegrated pressure reducerAutomatic voltage adjustmentCan be operated with laboratory glovesApplications:OmniaPure xstouch UV-TOC: Ultra trace analysis, ICP-MS, HPLC, TOC analysisOmniaPure xstouch UV-TOC/UF: Molecular and microbiology, cell culture mediaUltra pure water system OmniaPure xstouch in the under-bench version can be installed under a laboratory bench to save space. The external dispenser and monitoring unit OptiFilltouch is positioned on top of the bench.Scope of supply: Ultra pure water system, pre-treatment cartridge, ultra pure water cartridge, sterile filter capsule (0.2 µm)Ultra pure water output:Up to 2 l/minDispensing volume:0.05 ... 25 lResistivity at 25 °C:18.2 MΩ x cmConductivity at 25 °C:0.055 µS/cmBacteria (with filter):0.01 CFU/mlParticles (with filter):1/mlRNase (with UF module):1 pg/mlDNase (with UF module):5 pg/mlProteases (with UF module):0.15 µg/lFeed water conductivity at 25 °C:100 µS/cmDimensions device (W x D x H):240 x 310 x 415 mmDimensions bench dispenser (W x D x H):150 x 450 x 580 mmWeight device:13 kgWeight bench dispenser:8 kgPower supply:90 ... 240 V, 50 ... 60 Hz

Ultra pure water system OmniaPure xstouch, under-bench version with OptiFilltouch wall dispenser
For ultra pure water type I.Ultra pure water of the highest quality for analytical and life science applications in the laboratory. With the standard control and monitoring unit OptiFilltouch, laboratory vessels can be filled conveniently and precisely. The recirculation function prevents the growth of biofilms.Compact designCan be used with deionised waterDispenser pivotable up to 170°Digital control and monitoring unit OptiFilltouch with colour touch displayReal-time TOC monitoringAdjustable limit values for conductivity and TOCInnovative monitoring and display of cartridge capacityWithdrawal volume individually adjustablePermanent data storage of all quality parametersPassword access and error memory3 languages selectable: DE, EN, FRRS232 and USB interfaceLeakage sensorIntegrated pressure reducerAutomatic voltage adjustmentCan be operated with laboratory glovesApplications:OmniaPure xstouch UV-TOC: Ultra trace analysis, ICP-MS, HPLC, TOC analysisOmniaPure xstouch UV-TOC/UF: Molecular and microbiology, cell culture mediaUltra pure water system OmniaPure xstouch in the under-bench version can be installed under a laboratory bench to save space. The external dispenser and monitoring unit OptiFilltouch is positioned on the wall.Scope of supply: Ultra pure water system, pre-treatment cartridge, ultra pure water cartridge, sterile filter capsule (0.2 µm)Ultra pure water output:Up to 2 l/minDispensing volume:0.05 ... 25 lResistivity at 25 °C:18.2 MΩ x cmConductivity at 25 °C:0.055 µS/cmBacteria (with filter):0.01 CFU/mlParticles (with filter):1/mlRNase (with UF module):1 pg/mlDNase (with UF module):5 pg/mlProteases (with UF module):0.15 µg/lFeed water conductivity at 25 °C:100 µS/cmDimensions device (W x D x H):240 x 310 x 415 mmDimensions wall dispenser (W x D x H):100 x 460 x 520 mmWeight device:13 kgWeight wall dispenser:2.4 kgPower supply:90 ... 240 V, 50 ... 60 Hz

Ultra pure water system OmniaTap 12
For pure water and ultra pure water Type I + II.OmniaTap is the ideal system when both pure water and ultrapure water are required, but in relatively small amounts. It provides both types from a single system. These also make it possible to connect the system directly to a drinking water tap. A touch on the flexible OptiFill dispenser button activates dispensing of ultrapure water type I via the digital dispenser control. The recirculation of the pure water held in the installed 10 litre tank keeps it permanently at type II quality.Applications:OmniaTap 12: AAS, IC, ICP, buffers and media preparationOmniaTap 12 UV: Ultra-trace analysis, ICP-MS, HPLC, TOC-analysisOmniaTap 12 UV/UF: Life science and microbiology, cell culture mediaScope of supply: Ultra pure water system, filter cartridges, sterile filter capsule 0.2 µmSpecifications Type IIOmniaTap / OmniaTap UV / OmniaTap UV/UFUltrapure water output:6 or 12 l/hResistivity:15-10 MΩ-cmConductivity:0.067-0.1 µS/cmPure water tank pressurized outlet:optionalType IDispensing performance:up to 2 l/minResistivity:18.2 MΩ-cmConductivity:0.055 µS/cmBacteria (with end filter): 0.1 CFU/mlParticles (with end filter): 1/mlFeed water requirements:Drinking water according to DIN 2000Dimensions (W x D x H):390 x 615 x 720 mmWeight:20 kg / 21 kg / 21 kgPower supply:90-240 V, 50/60 Hz
Ultrafiltration cartridges Biopak®
For the production of pyrogen-, nuclease- and bacteria-free water at the point of dispense of water treatment systems.
Ultrapure polisher cartridge for water purification systems Barnstead™ GenPure™ and LabTower™ EDI
Suitable for all model variants.

Ultrapure water purification system Barnstead™ MicroPure™, ASTM I
The Thermo Scientific Barnstead MicroPure system provides ultrapure water (18.2 MO, 0.055 µS/cm) ASTM type I, for typical demand up to 15 l/day. All MicroPure systems meet the requirements of the international standards ASTM (type I), ISO 3696 (type 1), ASTM D1193 and CLSI-CLRW. A variety of innovative expansion options, such as UV-lamp with wavelenghts 185/254 nm and a backwashable ultrafilter with a flow rate up to 0.6 l/min, ensure optimal supply for all analytical and life science applications.MicroPure systems are supplied for immediate use with: pressure reducer, end filter, ultrapure water cartridgeProduct features:Pre-cleaned feed water (e.g. reverse osmosis, destillation, demineralised water) is treated by a filtration cartridge and optional UV / UF units to produce ultrapure waterCompact laboratory system for optional mounting on the laboratory bench or on the wallSimple and economical change of consumables due to easily accessible service hood and cartrige with quick release fasteners and AquaStoppSwivel-mounted display/keypad unit for setting and querying all operating and performance parameters such as limit values for ultrapure water qualityMicroPure ST systems supplied with integrated 6 l tank for mobile use in the laboratory. Feed water supply with pre-cleaned water is provied by this tankSpecificationsFlow rate, max.: Operating pressure: Temperature: Conductivity:1L/min 2 to 6 bar +2 °C to +35 °C 0.055 µS/cmResistance at 25°C:18.2 MΩxcmTOC value (models with UV): TOC value (models without UV):1 to 5 ppb 10 ppbBacterial content: Particles 0.2 µm/mL:1cfu/ml 1Endotoxins (Models with UF):0.001EU/mlPower consumption:0.06 kWPower supply:90-240 V, 50/60 Hz, automatic voltage regulation to 24 VDimensions (W x D x H): Dimensions models with reservoir (W x D x H):305 x 300 x 545 mm 305 x 400 x 545 mmWith UF = ultrafiltration, UV = UV photo-oxidation 185/254nm, UF / UV = Ultra Filtration and UV photo-oxidation 185/254 nm