Skip to main content Skip to search Skip to main navigation

Filter products

Gas analyzers MAT1400/MAT1500

Gas analyzers MAT1400/MAT1500

Gas analyzers MAT1000 series are used for measuring oxygen concentrations (O2) or optional carbon dioxide concentrations (CO2).Applies to all models of MAT1000 series:Easy and intuitive operation via touchscreen, even by untrained personnelCreate your own methodAvailable method parameters: scales, measurement procedures, limit values, comment and much moreSelectable measurement methods: single or continuousSeveral single measurement procedures: manual, automatic, min/max detectionShortcut keys for most important functionsShort measurement period, high accuracy even with small sample volumeValidation possibleCompliance with global standards such as GMP/GLP and 21 CFR Part 11Documentation of all measured values of the last 999 measurementsIntegrated interfaces, flexible data export (USB, Ethernet, RS-232)Compact design in robust cast aluminum housingBuilt-in air pressure sensorIntegrated flow rate monitoringGas analysers for controlling protective gas packaging. The MAT1400 equipped with a zirconium dioxide sensor (ZrO2) measures the oxygen concentration over the entire measurement range between 0 and 100 vol% and with an excellent accuracy of ±0.001 vol%. The MAT1500 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.For high sample throughputFor high O2 concentrationHigh precision with the lowest O2 concentrationsWide measurement rangeDrift-free zirconia sensor (ZrO2)Low-drift non-dispersive infrared sensor (NDIR), model MAT1500Environmental compensated CO2 measurement, model MAT1500SpecificationsO2 measuring range:0 to 100 Vol.-%Accuracy:0.001 Vol.-% (1 Vol.-%) 0.1 Vol.-% (6 Vol.-%) 0.1 Vol.-% (35 Vol.-%)Resolution: CO2 measuring range (only MAT1500):0.001 Vol.-% 0 to 50 Vol.-%Accuracy: Resolution:±0.5 Vol.-% 0.1 Vol.-%Average measurement period: Heating time:5 to 10 sec 10 minInterface:RS-232, USB, EthernetDimensions (W x D x H):200 x 350 x 150 mmWeight:4.6 kgPower consumption:60 WPower supply:100-250 V, 50/60 Hz

Regular price: €0.00
Gas Pump accuro®

Gas Pump accuro®

Fast measurement with one hand: The Dräger-Tube pump accuro® allows you to use the established Dräger-Tubes® to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already been calibrated and form a perfect unit with the Dräger-Tube pump.Fast measurement with one hand: The Dräger-Tube pump accuro® allows you to use the established Dräger-Tubes® to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already been calibrated and form a perfect unit with the Dräger-Tube pump.

Regular price: €0.00
Gas Pump accuro® set

Gas Pump accuro® set

Fast measurement with one hand: The Dräger-Tube pump accuro® allows you to use the established Dräger-Tubes® to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already been calibrated and form a perfect unit with the Dräger-Tube pump.Gas pump Dräger accuro® set consisting of:Dräger-Tubes® pump accuro®, ready bag, with tube opener and spare part set

Regular price: €0.00

Gas sampling tubes, DURAN® tubing

Gas sampling tubes, with two one-way stopcocks NS 14 (with retaining device), connections: capillary tube (outer dia. 8 mm, inner dia. 2,7 mm), glass olive (outer dia. 9 mm), with inscription label.

Regular price: €0.00
Gas sampling tubes, DURAN® tubing, with nozzle

Gas sampling tubes, DURAN® tubing, with nozzle

Gas sampling tubes, with nozzle (with thread GL14 and septa), with two one-way stopcocks NS14 (with retaining device), connections: capillary tube (outer dia. 8 mm, inner dia. 2.7 mm), glass olive (outer dia. 9 mm), with inscription label.

Regular price: €0.00
Gas sampling tubes, PP, one straight bore stopcock and one 3-way stopcock

Gas sampling tubes, PP, one straight bore stopcock and one 3-way stopcock

Stopcocks, PP, with free-turning PTFE plugs. Ends accept 6.4 to 9.5 mm I.D. tubing.Stopcocks, PP, with free-turning PTFE plugs. Ends accept 6.4 to 9.5 mm I.D. tubing.

Regular price: €0.00

Gas sampling tubes, PP, with one straight bore stopcock and one screw fitting

Stopcocks, PP, with free-turning PTFE plugs. Ends accept 6.4 to 9.5 mm I.D. tubing.Screw fitting with silicone rubber septum, 6 septa included.

Regular price: €0.00
Gas sampling tubes, PP, with straight bore stopcock on each end

Gas sampling tubes, PP, with straight bore stopcock on each end

Stopcocks, PP, with free-turning PTFE plugs. Ends accept 6.4 to 9.5 mm I.D. tubing.Stopcocks, PP, with free-turning PTFE plugs. Ends accept 6.4 to 9.5 mm I.D. tubing.

Regular price: €0.00
KOSTA 2 nitrogen station

KOSTA 2 nitrogen station

The two-stage concentration of the organic phase is concluded by reducing the extract down to less than 1 ml under a mild nitrogen flow.In the behrotest® nitrogen station, a distributor leads the nitrogen flow via two individually adjustable tubes into the Kuderna-Danish flasks. Thus, two samples can be reduced simultaneously in accordance with ISO 9377-2.

Regular price: €0.00
Laboratory purification plants to determine the biodegradability, according to DIN 38412

Laboratory purification plants to determine the biodegradability, according to DIN 38412

e.g. for the Coupled Units Test in acc. with OECD 303 A, complete.optional:Dentrification step with pump and stirrersOxygen control, consisting of:Oxygen measuring unit for preliminary sedimentation with a voltage output for switching the air supply on and off behrotest® GWS 200 limit switch. Operating capacity 0 to 200%, corresponds to 0 to 19.9 mg/l Vessels made of borosilicate glass 3.3Other laboratory purification plants on request.

Regular price: €0.00

Pollution monitor 3500+

Pollution monitors for collecting gases and vapours in the ambient atmosphere. Ideal for detecting pollutant concentration in the workplace. The 3M™ Pollution monitor is equipped with a single charcoal adsorbent wafer that binds pollutants in the air by means of diffusion.Suitable for personal and area monitoringEasy to use: the pollution monitor can simply be clipped onto clothingSmall and lightweight

Regular price: €0.00
Portable gas detectors series 04

Portable gas detectors series 04

Portable gas monitors to detect gases in the surrounding atmosphere. They measure concentrations of toxic gases and oxygen in the atmosphere and issue an alarm when gas concentrations reach preset levels. The alarms are indicated by flashing lamp, intermittent audible buzzer, flashing gas concentration readout and vibration.LCD displayR-sensor and CO-sensor with H2-reductionRobust constructionWater- and dust-proofBattery or rechargeable battery operationSpecificationsGas alarm:STEL Alarm, TWA Alarm, OverAlarm volume:80 dbHumidity:0 ... 95 % RH (OX-04G: 10 ... 90 % RH)Detection principle:Electrochemical type (OX-04G: galvanic cell type)Dimensions (W x D x H):54 x 24 x 67 mmWeight:93 gPower supply:2 x AAA alkaline batteries, or 2 x AAA rechargeble batteries (Ni-MH)Protection class:IP 66/67Warranty (sensor):3 years (OX-04G: 1 year)

Regular price: €0.00
Sampling bags, FEP, with on/off valve

Sampling bags, FEP, with on/off valve

Made from 5 mil (125 µm) FEP fluoropolymer film, these flexible, sturdy bags are heat sealed on all four sides for complete chemical resistance and leak-proof operation. They are inert to most chemicals and have low permeability which limits sample loss. These FEP bags are easy to use. They can be stored for an unlimited period prior to use. Applications include gas sample analysis, extracting air samples from smokestack exhaust systems, monitoring air quality or calibrating instruments in the field. The bags are individually packaged.Chemically resistantFlexibleWill not contaminate sampleWith a nickel-plated, brass on/off valve that accepts 6.4 mm I.D. flexible tubing.

Regular price: €0.00
Sampling bags, FEP, with septum

Sampling bags, FEP, with septum

Made from 5 mil (125 µm) FEP fluoropolymer film, these flexible, sturdy bags are heat sealed on all four sides for complete chemical resistance and leak-proof operation. They are inert to most chemicals and have low permeability which limits sample loss. These FEP bags are easy to use. They can be stored for an unlimited period prior to use. Applications include gas sample analysis, extracting air samples from smokestack exhaust systems, monitoring air quality or calibrating instruments in the field. The bags are individually packaged.Chemically resistantFlexibleWill not contaminate sampleWith PTFE/silicone septum in polypropylene housing for use with a hypodermic needle.

Regular price: €0.00
Sampling bags, PVDF, with on/off valve

Sampling bags, PVDF, with on/off valve

Reusable bags made of 2 mil (50 µm) PVDF fluoropolymer film, Chemware® Gas Bags offer an economical alternative for analysis of noncorrosive gases. Durable, heat-sealed seams ensure leak-proof operation. Applications include sampling carbon monoxide, sulfur dioxide, hydrogen sulfide, radon and mercaptan. The bags are individually packaged. When used for liquid samples, bags should be supported with a tray. Custom sizes and configurations available on request.FlexibleWill not contaminate sampleFor use in gas sampling trainsUse for gas or liquid sample containmentWith a nickel-plated, brass on/off valve that accepts 6.4 mm I.D. flexible tubing.

Regular price: €0.00
Sampling bags, PVDF, with septum

Sampling bags, PVDF, with septum

Reusable bags made of 2 mil (50 µm) PVDF fluoropolymer film, Chemware® Gas Bags offer an economical alternative for analysis of noncorrosive gases. Durable, heat-sealed seams ensure leak-proof operation. Applications include sampling carbon monoxide, sulfur dioxide, hydrogen sulfide, radon and mercaptan. The bags are individually packaged. When used for liquid samples, bags should be supported with a tray. Custom sizes and configurations available on request.FlexibleWill not contaminate sampleFor use in gas sampling trainsUse for gas or liquid sample containmentWith a PTFE/silicone septum in a polypropylene housing for use with a hypodermic needle.

Regular price: €0.00
Test gas in disposable bottles

Test gas in disposable bottles

According to ISO 9002.DOT39 and EN12205.Control valve not included, please order separately.

Regular price: €0.00