Skip to main content Skip to search Skip to main navigation

Filter products

2in1 KITs with short thread vials ND9

2in1 KITs contain short thread vials ND9 (1.5 ml) with a wide opening and screw caps in a blue PP box.

Regular price: €0.00
Accessories and replacement parts for EC columns

Accessories and replacement parts for EC columns

Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart® guard column cartridges with 8mm length with the guard column adaptor EC, packed with NUCLEODUR® spherical silica.

Regular price: €0.00

Accessories for bottle attachments

Regular price: €0.00

Accessories for CHROMABOND®

Regular price: €0.00

Accessories for gas and vapour sampler kit

Regular price: €0.00

Accessories for Precision hydrogen generators

For Precision Hydrogen and Precision Hydrogen trace models.

Regular price: €0.00

Accessories for Sample Concentrators SBHCONC / 1

Regular price: €0.00
Accessories for sprayers

Accessories for sprayers

Regular price: €0.00
Accessories for thin layer chromatography

Accessories for thin layer chromatography

Regular price: €0.00

Acylation kit

For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.Which is the proper reagent for acylation?Test kit for determination of the optimum acylation.

Regular price: €0.00

Acylation reagents for GC - Anhydrides

For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.Acylation with fluorinated acid anhydrides can be used for alcohols, phenols, carboxylic acids, amines, amino acids and steroids forming volatile, stable derivatives suited for FID as well as for ECD detection.by-products of acylation with anhydrides: corresponding acidsexcess reagent and the acid formed have to be removedHeptafluorobutyric acid anhydride (HFBA)m.w. 410.06, Bp 106 - 107°C (760mm Hg),C3F7 - CO - O - CO - C3F7density d20°/4° = 1.665

Regular price: €0.00

Acylation reagents for GC - Bisacylamides

For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.Reagents for silylation - alkylation (methylation) - acylation are available.Acylation with fluorinated acid amides is recommended for alcohols, primary and secondary amines as well as for thiols under mild, neutral conditions. MBTFA also forms very volatile derivatives with carbohydrates.by-products: corresponding neutral acylamides, which can be easily removed due to their high volatility; because of neutral conditions and favourable chromatographic properties often removal of the bisacylamide is not necessary. Thus sample preparation is much more convenient.MBTFA / MBHFBAN-methyl-bis(trifluoroacetamide) MBTFAm.w. 223.08, Bp 123 - 124°C (760mm Hg), density d20°/4° = 1.55,CF3 - CO - N(CH3) - CO - CF3Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture.The derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used soon.

Regular price: €0.00
ADAMANT unmodified standard silica layers for TLC

ADAMANT unmodified standard silica layers for TLC

Support materials for TLC ready-to-use layersGlass plates: glass, ~ 1.3 mm thick, high requirements for weight, packaging and storage, ideal torsional strength, high temperature stability, susceptible to breakage, can not be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, suitability for aqueous detection reagents depends on the phasePOLYGRAM®: polyester, ~ 0.2 mm thick, low requirements for weight, packaging and storage, low torsional strength, max. 185 °C temperature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, very suitable for aqueous detection reagentsALUGRAM®: aluminium, ~ 0.15 mm thick, low requirements for weight, packaging and storage, relatively high torsional strength, high temperature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, low resistance against mineral acids and conc. ammonia, limited suitability for aqueous detection reagentsSilica 60, specific surface (BET) ~ 500m²/g, mean pore size 60Å, specific pore volume 0.75ml/g, particle size 5 to 17µm. Outstanding hardness and abrasion resistance due to an optimized binder system. Increased separation efficiency due to an optimized particle size distirbution. High suitability for trace analyses resulting from a UV indicator with brilliance and a low-noise background of the layer.Available as glass plates with or without fluorescent indicator (UV254).

Regular price: €0.00
Adapter for exhaust filter, PP

Adapter for exhaust filter, PP

For space saving mounting on b.safe Waste Caps.

Regular price: €0.00
Adapter for Safety Waste Caps V3.0, electrostatic conductive

Adapter for Safety Waste Caps V3.0, electrostatic conductive

Extension GL25 connection.

Regular price: €0.00
Adapters for capillary connections, PP

Adapters for capillary connections, PP

For assembly of an exhaust filter on a capillary connection.

Regular price: €0.00

Adapters for CHROMABOND® glass columns

Regular price: €0.00

Adapters for CHROMABOND® polypropylene columns

Regular price: €0.00
Adapters for exhaust filter connection

Adapters for exhaust filter connection

For installation of capillaries at exhaust filter connection of b.safe Waste Caps. The adapter made of PE-EX is conductive.

Regular price: €0.00
Adapters for exhaust filters

Adapters for exhaust filters

Space problems in the lab? Use the adapters for the exhaust filter to gain more free space. Attach the exhaust filter in any position - perfect when dealing with lower installation heights.

Regular price: €0.00
Air compressor for GC

Air compressor for GC

For compressed air supply of Precision nitrogen and zero air generators for the GC.For simultaneous supply of nitrogen and zero air generators in one stackCan be stacked and combined with all Precision modulesVery quiet and low-vibration operationWith maintenance and repair status displaysScope of supply: 3 m PTFE tubing, 2 x 1/4" compression fitting, 1/4" tee compression fitting, 2.5 mm hex key, mains power cable for EU, UK and USSpecifications:Max. pressure:8.27 bar / 120 psiGas connection:1/4"Permissible ambient temperature:5 ... 35 °CDimensions (W x D x H):380 x 540 x 406 mmWeight:42 kgPower supply:208 ... 230 V, 50/60 HzWarranty:1 year

Regular price: €0.00
Air valves for Eluent SafetyCaps

Air valves for Eluent SafetyCaps

Air valves prevent the formation of vacuum in HPLC bottles.PTFE membrane1/4"-28 thread portWith timestrip sticker

Regular price: €0.00
Air valves Generation 2.0 for SafetyCaps

Air valves Generation 2.0 for SafetyCaps

Thread size UNF 1/4" 28GLuer Lock adapterPTFE FilterValve membrane blocks vapours and opens at negative pressureIt is recommended to replace the valve every 6 monthsWith change indicator and labelling field for timely change

Regular price: €0.00
Air valves, PP

Air valves, PP

Red/yellow. With connecting thread UNF ¼" 28G. Filter membrane made of PTFE/PP with a porosity of 1 µm and integrated non-return valve made of silicone. With service life indicator.

Regular price: €0.00