EC analytical columns NUCLEODUR® C8 Gravity, 1.8 µm

EC analytical columns NUCLEODUR® C8 Gravity, 1.8 µm

NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 1.8 µm, 11 % C.

Regular price: €0.00
EC analytical columns NUCLEODUR® C8 Gravity, 5 µm

EC analytical columns NUCLEODUR® C8 Gravity, 5 µm

NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 5 µm, 11 % C

Regular price: €0.00

EC analytical columns NUCLEODUR® Sphinx RP, 1.8 µm

Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsParticle size 1.8 µm, 15 % C

Regular price: €0.00

EC analytical columns NUCLEODUR® Sphinx RP, 3 µm

Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsParticle size 3 µm, 15 % C

Regular price: €0.00

EC analytical columns NUCLEODUR® Sphinx RP, 5 µm

Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsParticle size 5 µm, 15 % C

Regular price: €0.00

EC analytical columns NUCLEOSIL® 100-5 C18 PAH, 5 µm

Special octadecyl phase for PAH analysis.Base material NUCLEOSIL® silica, particle size 5 µm, pore size 100 Å; polymeric coating - USP L1; eluent in column acetonitrile/water 70:30; allows efficient gradient separation of the 16 PAH in accordance with EPA.Detection of the separated PAH by UV (250 to 280 nm), with diode array or with fluorescence detection at different wavelegths for excitation and emission (acenaphthylene cannot be analysed with fluorescence detection).Guard columns for EC columns NUCLEOSIL® 100-5 C18 PAH, 5 µm available on request.

Regular price: €0.00
EC analytical HPLC columns, NUCLEODUR PFAS

EC analytical HPLC columns, NUCLEODUR PFAS

Hydrophobic reversed phase with distinct polar selectivity for special PFAS analysis. This HPLC phase is made of high purity NUCLEODUR HPLC silica gel and is extensively endcapped. Due to a low bleeding characteristics these columns are suitable for high sensitivity LC/MS analysis.

Regular price: €0.00
EC analytical HPLC columns, NUCLEODUR PFAS Delay

EC analytical HPLC columns, NUCLEODUR PFAS Delay

NUCLEODUR PFAS Delay columns trap and therefore delay system-related PFAS contaminants, ensuring trace level analysis of PFAS in your samples. This HPLC phase is made of high purity NUCLEODUR HPLC silica gel and is extensively endcapped. Due to a low bleeding characteristics these columns are suitable for high sensitivity LC/MS analysis.

Regular price: €0.00
Guard column holder CC

Guard column holder CC

Guard column holder, incl. nuts and ferrules.

Regular price: €0.00
Guard columns for EC columns NUCLEODUR® C18 Gravity, 3µm

Guard columns for EC columns NUCLEODUR® C18 Gravity, 3µm

NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsGuard columns for EC columns require guard column adapter EC (Cat. No. 7.081 898)

Regular price: €0.00

Guard columns for EC columns NUCLEODUR® C18 Isis, 3 µm

C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsGuard columns for EC columns require the guard column adapter EC.

Regular price: €0.00
Guard columns for EC columns NUCLEODUR® C18Gravity, 5µm

Guard columns for EC columns NUCLEODUR® C18Gravity, 5µm

NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsGuard columns for EC columns require guard column adapter EC (Cat. No. 7.081 898)

Regular price: €0.00

Guard columns for NUCLEOGEL® SUGAR 810 Ca columns

Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyThis guard columns require the CC column holder 30 mm.

Regular price: €0.00

Guard columns for NUCLEOGEL® SUGAR 810 H columns

Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyThis guard columns require the CC column holder 30 mm.

Regular price: €0.00
HPLC Detector lamps

HPLC Detector lamps

Regular price: €0.00

NUCLEOGEL® SUGAR 810 Ca

Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyValco type columns for separation of mono-, di- and oliogosaccharides - USP L19 eluent in column water.

Regular price: €0.00

NUCLEOGEL® SUGAR 810 H

Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyValco type columns for separation of sugars, sugar alcohols and organic acids - USP L17 eluent in column 0.01 N H2SO4

Regular price: €0.00
Preparative HPLC columns Nucleosil®100-5 C18

Preparative HPLC columns Nucleosil®100-5 C18

Grain size 5 µm, pore dia. 100 Å. Octadecyl phase, endcapped, 15 % C.

Regular price: €0.00

VarioPrep columns for preparative HPLC C18 Pyramid, 5 µm

Stable in 100 % aqueous eluent systems- USP L1Pore size 110 ÅInteresting polar selectivity featuresExcellent base deactivation; suitable for LC/MS due low bleeding characteristicspH stability 1 - 9Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acidsVarioPrep guard columns require a VP guard column holder.

Regular price: €0.00

VarioPrep columns for preparative HPLC NUCLEODUR® C18 Isis, 5 µm

C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsVarioPrep guard columns require a VP guard column holder.

Regular price: €0.00

VarioPrep columns for preparative HPLC NUCLEODUR® Sphinx RP, 5 µm

Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsVarioPrep guard columns require a VP guard column holder.

Regular price: €0.00

VarioPrep columns for preparative HPLC, NUCLEODUR® 100-5 C8 ec, 5 µm

Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.VarioPrep guard columns require a VP guard column holder.

Regular price: €0.00

VarioPrep columns for preparative HPLC, NUCLEODUR® 100-5, 100-7, 100-10 C18 ec

Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.VarioPrep guard columns require a VP guard column holder.

Regular price: €0.00
VarioPrep guard column holders and replacement parts

VarioPrep guard column holders and replacement parts

VarioPrep columnscolumn system for preparative HPLC manufactured from stainless steel with two adjustable end fittings, allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column, packed with NUCLEODUR® and NUCLEOSIL® spherical silica.O-rings available on request.

Regular price: €0.00