Alcoholmeters with thermometer
Alcoholmeters with an error limit of ±0.1 % vol. Temperature range from 0 to 30 °C with 0.5 °C graduation and an accuracy of ±1 °C. Blue filling. Packed in square plastic sleeve.

Alcoholometer according to E.E. 76/765
According to E.E. 76/765. Class II, ethanol % vol. Suitable for official testing. Reference temperature: 20 °C. With thermometer.

Alcoholometer, Richter-Tralles type
0 to 100 % mas / % Vol at reference temperature: +20°C.Without thermometer. With DAkkS calibration certificate and 3 checkpoints.Packed in a square plastic sleeve.

Alcoholometer, Richter-Tralles type
0 to 100% at reference temperature: 20°C.Without thermometer.

ASTM Hydrometers
Precision hydrometers acc. to ASTM E2995-14 for determination of density for mineral oil, with thermometer "mercury free".Hydrometer with thermometer, error-limit for density: ± 0,5 kg/m³, with thermometer -20 to +65°C in 1°C, blue filling, error-limit ± 1°C. With works calibration on request. With blue, environmental friendly filling of thermometers. Each item packed in plasic tubes for breakage protection.

ASTM Hydrometers, with works calibration and 3 checkpoints
Precision hydrometers acc. to ASTM E2995-14 for determination of density for mineral oil, with thermometer "mercury free".Hydrometer with thermometer, error-limit for density: ± 0,5 kg/m³, with thermometer -20 to +65°C in 1°C, blue filling, error-limit ± 1°C. With blue, environmental friendly filling of thermometers. Each item packed in plasic tubes for breakage protection.

Battery hydrometer
Battery acid tester 1.10 to 1.30.Boxed complete with glass tube, rubber bulb and hydrometer.

Density hydrometers without thermometer
Scale 0,300 up to 0,500 g/cm³, paper scale, shot weighted body, hydrometer accuracy ±1 scale division, capilary round, in transparent plastic case. Reading below.

Density hydrometers without thermometer
Scale 0,100 g/cm³, paper scale, shot weighted body, hydrometer accuracy ±1 scale division, in transparent plastic case. Reading below.

Density hydrometers without thermometer
Scale 0,100 g/cm³, paper scale, shot weighted body, hydrometer accuracy ±1 scale division, in transparent plastic case. Reading below.* Complete set with 14 insturments in stuffed case.

Hydrometer
Acc. to DIN 12791. Error limit ±0.001 g/cm3.Packed in a square plastic sleeve.

Hydrometer cylinders, PP
Highly transparent. For density measurements using a hydrometer. Hydrometer can be read through the overflow vessel with a completely filled cylinder.With spoutMolded graduations and ring marks at the primary scale pointsCalibrated to contain (IN)Hexagonal base with bottom studs


Hydrometer racks, PP
Rack with 10 positions for storing, drying and transporting hydrometers. The teardrop-shaped slots are labelled with identification numbers and hold hydrometers with a diameter of up to 31 mm securely in place. The 3-tier design and the stable, wide base ensure greater stability and protection. The removable drip tray makes cleaning easy. Built-in handles provide a convenient grip for safe transport in the laboratory.

Hydrometer, Casagrande
Casagrande type, acc. to DIN 18123 / BS 1377. Error limit of ±0.0005 g/cm3.Packed in a square plastic sleeve.

Hydrometers according to Baumé, without thermometer
Scale ranges from 0° up to 70° Baumé, paper scale with well visible print, shot weighted body, at the bottom pointed end, accuracy ±1 line of scale division, reading below.


Hydrometers for hydrochloric acid in %
Without thermometer.Without thermometer.

Hydrometers for hydrogen peroxide in %
Without thermometer.Without thermometer.



Hydrometers for special applications, must scale according to Oechsle
Reference temperature: 20°C. Without thermometer.Reference temperature: 20°C. Without thermometer.